5 resultados para work zone traffic control

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing of the number of attacks in the computer networks has been treated with the increment of the resources that are applied directly in the active routers equip-ments of these networks. In this context, the firewalls had been consolidated as essential elements in the input and output control process of packets in a network. With the advent of intrusion detectors systems (IDS), efforts have been done in the direction to incorporate packets filtering based in standards of traditional firewalls. This integration incorporates the IDS functions (as filtering based on signatures, until then a passive element) with the already existing functions in firewall. In opposite of the efficiency due this incorporation in the blockage of signature known attacks, the filtering in the application level provokes a natural retard in the analyzed packets, and it can reduce the machine performance to filter the others packets because of machine resources demand by this level of filtering. This work presents models of treatment for this problem based in the packets re-routing for analysis by a sub-network with specific filterings. The suggestion of implementa- tion of this model aims reducing the performance problem and opening a space for the consolidation of scenes where others not conventional filtering solutions (spam blockage, P2P traffic control/blockage, etc.) can be inserted in the filtering sub-network, without inplying in overload of the main firewall in a corporative network

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Artificial Intelligence techniques are applied to improve performance of a simulated oil distillation system. The chosen system was a debutanizer column. At this process, the feed, which comes to the column, is segmented by heating. The lightest components become steams, by forming the LPG (Liquefied Petroleum Gas). The others components, C5+, continue liquid. In the composition of the LPG, ideally, we have only propane and butanes, but, in practice, there are contaminants, for example, pentanes. The objective of this work is to control pentane amount in LPG, by means of intelligent set points (SP s) determination for PID controllers that are present in original instrumentation (regulatory control) of the column. A fuzzy system will be responsible for adjusting the SP's, driven by the comparison between the molar fraction of the pentane present in the output of the plant (LPG) and the desired amount. However, the molar fraction of pentane is difficult to measure on-line, due to constraints such as: long intervals of measurement, high reliability and low cost. Therefore, an inference system was used, based on a multilayer neural network, to infer the pentane molar fraction through secondary variables of the column. Finally, the results shown that the proposed control system were able to control the value of pentane molar fraction under different operational situations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The of Serrinha plutonic suite, northeastern portion of the Borborema Province (NE Brazil), is characterized by a voluminous and diversified magmatism of Neoproterozoic age, intrusive in the Archean to Paleoproterozoic gneissic-migmatitic basement of the São José de Campestre massif. Field relations and petrographic and geochemical data allowed us to individualize different lithologic types among this plutonic suite, which is represented by intermediate to mafic enclaves, porphyritic diorites, porphyritic granitoids, porphyritic granodiorites, microporphyritic granites and dykes/sheets of microgranite. The intermediate-to-mafic enclaves occur associated with porphyritic granitoids, showing mixture textures. The porphyrytic diorites occur as isolated bodies, generally associated with intermediate-to-mafic enclaves and locally as enclaves within porphyritic granites. The granodiorites represent mixing between an intermediate to mafic magma with an acidic one. The micropophyritic granites occur as isolated small bodies, generally deformed, while the microgranite dykes/sheets crosscut all the previous granitoids. A U-Pb zircon age of 576 + 3 Ma was obtained for the Serrinha granite. This age is interpreted as age of the peak of the regional ductile deformational event (D3) and of the associated the E-W Rio Jacu shear zone, which control the emplacement of the Neoproterozoic syntectonic plutons. The porphyrytic granitoids show monzogranitic composition, transitional between peraluminous and metaluminous types, typically of the high potassium subalkaline-calc-alkaline series. The intermediate-to-mafic enclaves present vary from quartz diorite to tonalite/granodiorite, with metaluminous, shoshonitic affinity. The diorites are generally quartz-monzodiorite in composition, with metaluminous, subalkaline affinity. They display coarse-grained, inequigranular, porphyrytic texture, with predominance of plagioclase phenocrystals immersed in a matrix composed of biotite and pyroxenes. The microporphyrytic granites are essentially monzogranites of fine- to medium-grained texture, whereas microgranite dikes/sheets varying from monzogranites to syenogranites, with fine to media texture, equigranular. The diversified magmatism occurring at a relatively small surface associated with shear zones, suggests lithospheric dimensions for such structures, with magma extractions from different depths within the lower crust and upper mantle. The geological, geochemical and geochronological characteristics of the Serrinha plutonic suite suggest a pos-collisional geodynamic context for the Neoproterozoic magmatism. Thermobarometric data show emplacement conditions in the range 5-6 kbar (AlTamphibole) and 730-740°C (plagioclase-amphibole) for the porphyrytic granitoids (Serrinha body) and the intermediate-to-mafic enclaves

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The development of wireless telecommunication in the last years has been great. It has been taking academics to conceive new ideas and techniques. Their aims are to increase the capacity and the quality of the system s services. Cells that are smaller every time, frequencies that are every time higher and environments that get more and more complex, all those facts deserve more accurate models the propagation prediction techniques are inserted in this context and results with a merger of error that is compatible with the next generations of communication systems. The objective of this Work is to present results of a propagation measurement campaign, aiming at pointing the characteristics of the mobile systems covering in the city of Natal (state of Rio Grande do Norte, Brazil). A mobile laboratory was set up, using the infra-structure available and frequently used by ANATEL. The measures were taken in three different areas: one characterized by high buildings, high relief, presence of trees and towers of different highs. These areas covered the city s central zone, a suburban / rural zone and a section of coast surrounded by sand dunes. It is important to highlight that the analysis was made taking into consideration the actual reality of cellular systems with covering ranges by reduced cells, with the intent of causing greater re-use of frequencies and greater capacity of telephone traffic. The predominance of telephone traffic by cell in the city of Natal occurs within a range inferior to 3 (three) km from the Radio-Base Station. The frequency band used was 800 MHz, corresponding to the control channels of the respective sites, which adopt the FSK modulation technique. This Dissertation starts by presenting a general vision of the models used for predicting propagation. Then, there is a description of the methodology used in the measuring, which were done using the same channels of control of the cellular system. The results obtained were compared with many existing prediction models, and some adaptations were developed by using regression techniques trying to obtain the most optimized solutions. Furthermore, according to regulations from the old Brazilian Holding Telebrás, a minimum covering of 90% of a determined previously area, in 90% of the time, must be obeyed when implanting cellular systems. For such value to be reached, considerations and studies involving the specific environment that is being covered are important. The objective of this work is contribute to this aspect