9 resultados para ultrasonic cavitation

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epoxy based nanocomposites with 1 wt % and 3 wt % of nanographite were processed by high shear mixing. The nanographite was obtained by chemical (acid intercalation), thermal (microwave expansion) and mechanical (ultrasonic exfoliation) treatments. The mechanical, electrical and thermal behavior of the nanocomposites was determined and evaluated as a function of the percentage of reinforcement. According to the experimental results, the electrical conductivity of epoxy was not altered by the addition of nanographite in the contents evaluated. However, based on the mechanical tests, nanocomposites with addition of 1 wt.% and 3 wt.% of nanographite showed increase in tensile strength of 16,62 % and 3,20 %, respectively, compared to the neat polymer. The smaller increase in mechanical strength of the nanocomposite with 3 wt.% of nanographite was related to the formation of agglomerates. The addition of 1 wt.% and 3 wt.% of nanographite also resulted in a decrease of 6,25 % and 17,60 %, respectively, in the relative density of the material. Thus, the specific strength of the nanocomposites was approximately 33,33 % greater when compared to the neat polymer. The addition of 1 wt.% and 3 wt.% of nanographite in the material increased the mean values of thermal conductivity in 28,33 % and 132,62 %, respectively, combined with a reduction of 26,11 % and 49,80 % in volumetric thermal capacity, respectively. In summary, it has been determined that an addition of nanographite of the order of 1 wt.% and 3 wt.% produced notable elevations in specific strength and thermal conductivity of epoxy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

All medicine, whether allopathic or homeopathic, must go through strict quality control, which must ratify their characteristics throughout the period of validity. During the time of preparation and storage, solutions of the drugs are in permanent contact with packaging materials that can release undesirable substances to the solution. Several factors may influence the release of packing materials, and factorial design (FD) is a useful tool for analyzing the phenomenon. The aim of this study was the determination of quality parameters for Homeopathic solid (globules) and liquid (drops) dosage forms. It was carried out analysis in homeopathic globules for weight variation, mechanical strength, and moisture content uniformity. For liquid preparations, standard solutions were prepared from natural rubber bulbs, which were subjected to exhaustive extraction with two ethanol solutions (30 and 70%) in the ultrasonic bath for 20 minutes at 25°C and 50°C in three successive cycles. Studies of transfer have been made within five days, by spectrophotometric analysis in the UV region at 312 nm with λmáx and 323 nm for samples in 70% ethanol and 30% respectively. PH values were analyzed. We also conducted two FD studies, where the first, the three-level variables were solvent (chloroform, ethanol and nhexane), sample mass (30, 60 and 90mg), particle size (large disk, small disk and powder sample). In the second study, the solvent level variables were different ethanolic degrees (EtOH 30%, 70% and pure). The percentage of lending in the solutions was 5.5%, 12.4%, 24.2% and 41% of the total estimated in the reference solution. The values of rate constants of transfer were determined in the order of 0.0134 days-1 and 0.0232 days-1 in absorbance values, the solutions in ethanol at 30% and 70% respectively. These results suggest that the speed of transfer of materials from rubber is affected both by the nature of the vehicle as by the temperature

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In general, the designs of equipment takes into account the effects and processes of deterioration it will undergo and arrives at an approximate useful life. However, changes in operational processes and parameters, the action of external agents, the kind of maintenance conducted, the means of monitoring, and natural and accidental occurrences completely modify the desired performance of the equipment. The discontinuities that occur in anisotropic materials often and due to different factors evolve from being subcritical to critical acquiring the status of defect and compromising the physical integrity of the equipment. Increasingly sophisticated technological means of detection, monitoring and assessment of these discontinuities are required to respond ever more rapidly to the requirements of industry. This paper therefore presents a VPS (Virtual Pipe System) computational tool which uses the results of ultrasonic tests on equipment, plotting the discontinuities found in models created in the CAD and CAE systems, and then simulates the behavior of these defects in the structure to give an instantaneous view of the final behavior. This paper also presents an alternative method of conventional ultrasonic testing which correlates the integrity of an overlay (carbon steel and stainless steel attached by welding) and the reflection of ultrasonic waves coming from the interface between the two metals, thus making it possible to identify cracks in the casing and a shift of the overlay

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A batch of eighty-four coupons of low carbon steel were investigated at laboratory conditions under a corrosive, cavitative-corrosive (CO2) and corrosive-erosive (SiO2 + CO2) in an aqueous salt solution and two levels of temperature. The following measurements were made on Vickers (HV0,05, HV0,10, HV0,20) Microhardness tests at three levels of subsurface layer. A turbulent flow collided on the cylindrical sample, with and without mechanical stirring and gas bubbling, with and without fluid contamination by solid particles of SiO2, at two temperatures. Surface Roughness and Waviness, under two conditions "as received, after machining" and "after worn out", as well as gravimetric and electrochemical parameter were measured on the two opposite generatrices of each cylindrical sample, on the flow upstream (0°) and downstream (180°) by Profilometry, Mass Variation and Linear Polarization Resistance (LPR). The results of the Microhardness and Surface Texture of all coupons were subjected to statistical comparison, using the software Statgraphics® Centurion XVI, 95% statistical certainty, and significant differences were observed in some arrays of measurements. The corrosive wear rate measured by LPR and mass variation shown to be sensitive to the presence of bubbles and hydrodynamic fluctuations inside the cell, considering the temperature and contamination of corrosive fluid by solid particles. The main results of visual inspection relative to some topologies of the surface damages involving different mechanisms that were seen to give explanation for some fluctuations in wear rates of the steel experimentally investigated

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the displacement of petroleum/diesel solutions, at different concentrations, observing the effect of ultrasonic vibrations in fluids present in porous media to obtain an increase in oil production. The bubbles produced by ultrasound implode asymmetrically in the rock, generating liquid jets with high speed, displacing the oil present in porous media. The oil/diesel solutions were prepared with concentrations ranging from 20 g/L to 720 g/L in oil in relation to diesel and its viscosities were obtained in a Brookfield Rheometer RS2000, with temperature ranging from 25 to 55 °C. After, calculations were performed to obtain the activation energy data for oil/diesel solutions. For oil recovery experiments, cylindrical samples of porous rock (core samples), with resin around the perimeter and its two circular bases free to allow the passage of fluids, were first saturated with 2% KCl solution and after with oil solutions. The results of oil extraction were satisfactory for all studied solutions, being obtained up to 68% partial displacement with saline solution injection. The ultrasound system was used after saline injection, increasing oil displacement, with oil extractions ranging from 63% to 79%. During the experiments, it was observed the warming of core samples, helping to reduce the viscosity of more concentrated systems, and consequently enhancing the percentage of advanced recovery for all studied solutions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this approach is to describe the design and construction of a low-cost automated water sampler prototype. In recent years, there is an increasing need on the use of automated equipments for hydro climatic variables to be use in urban and rural environments. Such devices are always used to provide measured information which is of crucial importance on the development of water resources strategies at watershed scale. Actually, many research and water public institutions have been using these kinds of equipments. In most of the cases, automated equipments are expensive and need to be imported, generating a situation of technologic dependency. The prototype is based on an electronic system which controls a peristaltic pump functioning, five solenoid valves and an ultrasonic sensor connected to a datalloger. An interface with the user allows communication with a PC, when the equipment functioning parameters can be provided. The equipment has a hydraulic module composed by a 12V peristaltic pump connected to a distribution circuit composed by five solenoid valves, one of them being used to clean the circuit before each sampling procedure. Samples are collected by four 1.95 polyethylene bottles. The sampler body was made of acrylic material, with a cylindrical shape, and dimensions 0.72 m and 0.38 m height and diameter, respectively. The weight of the equipment without samples is approximately 15 kg, which infers to its portability. The prototype development total cost budget was approximately US$ 1,560.00. Laboratory tests aimed to evaluate the equipment performance and functioning demonstrated satisfactory results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental caries consists in a multifactorial and dynamic process. The knowledge of the ionic interactions among dental tissues and dental biofilm make possible its understanding as a process that can be stopped. Recently, the use of sealants have lost its function as preventive agent and passed to be argued as a possible therapeutical agent. This happens by hindering the substratum flow to the lesion inner and, therefore, controls the advance of the process. This study aimed to evaluate glass ionomer cement as a not invasive technique of treatment in occlusal caries without clinical cavitation, but with dentinal involvement. The research was accomplished using a controlled clinical trial with two groups (experimental and control) in 38 subjects (8-18 years) with 51 molars. The teeth of the experimental group were sealed with glass ionomer cement (Vidrion-R, S.S.White, Juiz de Fora, Brazil) and the molars control did not suffer intervention. The experimental group was followed by a year and the control by 8 months due the progression of the carious injury. Both groups were reevaluated to each 4 months with the use of clinical, radiographic and laser fluorescence (DIAGNOdent®) examination. The analysis of the clinical evaluation did not observe a significant difference between experimental and control groups. However, analysis with radiographic and laser fluorescence (DIAGNOdent®) examination observed a significant difference (p> 0,05) between groups, demonstrating a wors condition to the group without intervention. The results suggest that glass ionomer cement as sealant can be efficient to paralyze dentinal caries without clinical cavitation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cultivation of microalgae biomass in order to produce biodiesel arises as an extremely promising aspect, in that the microalgae culture includes short cycle of reproduction, smaller areas for planting and residual biomass rich in protein content. The present dissertation evaluates the performance and features, through spectrometry in the region of infrared with transformed Fourier (FTIR) and spectrometry in the region of UVvisible (UV-Vis), of the extracted lipid material (LM) using different techniques of cell wall disruption (mechanical agitation at low and at high spin and agitation associated with cavitation). The technique of gas chromatography (GC) brought to light the success of alkaline transesterification in the conversion of oil into methyl monoesters (MME), which was also analyzed by spectroscopic techniques (FTIR, proton magnetic resonance (1H NMR) and carbon (13C NMR). Through thermogravimetric analysis (TGA) were analyzed the lipid material (LM), biodiesel and the microalgae biomass. The method which provided the best results concerning the efficiency in extraction of the LP of Monoraphidium sp. (12,51%) was by mechanical agitation at high spin (14 000 rpm), for 2 hours being the ideal time, as shown by the t test. The spectroscopic techniques (1H NMR, 13C NMR and FTIR) confirmed that the structure of methyl monoesters and the chromatographic data (CG) revealed a high content of saturated fatty acid esters (about 70%) being the major constituent eicosanoic acid (33,7%), which justifies the high thermal stability of microalgae biodiesel. The TGA also ratified the conversion rate (96%) of LM into MME, pointing out the quantitative results compatible with the values obtained through GC (about 98%) and confirmed the efficiency of the extraction methods used, showing that may be a good technique to confirm the extraction of these materials. The content of LM microalgae obtained (12,51%) indicates good potential for using such material as a raw material for biodiesel production, when compared to oil content which can be obtained from traditional oil for this use, since the productivity of microalgae per hectare is much larger and requires an extremely reduced period to renew its cultivation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of the present study is to integrate a geological and technological investigation of ornamental rocks of the Flores and Jacarandá granites, which are located near the Afonso Bezerra city, in the north central part of the Rio Grande do Norte State. The study area encompasses four litho-stratigrafic units: a Gneiss-Migmatitic Complex(cristalline basement), which is mainly composed of banded gneisses, usually deformed as mylonitic rocks and with several migmatic features, an Augen Gneiss, which occurs as an elongated body that constitutes the Jacarandá granite, a small granite stock, which presents a semi-circular form, named Flores granite, composed of pink, fine to medium coarse rocks, and fine to coarse alluvial sediments, which form extensive areas of large fluvial deposits. The technological characterization of the Flores and Jacarandá granites, carried out through several tests, has as the main purpose the determination of petrographic, physical, and mechanic parameters that allowed the characterization of these rocks. The test followed procedures recommended by Brazilian (ABNT Associação Brasileira de Normas Técnicas) and foreigner institutions (ASTM American Society for Testing and Materials). The petrografhic analysis indicated that the rocks investigated are granite sensu estrictu, summing an average 85-90% modal. The Flores granite is the more felsic rock, which presents mafic content ∼ 10% and monzonitic composition. The Jacarandá granite is an Augen Gneiss rock that presents sienogranitic composition and mafic modal content ∼ 15%. Several technological tests carried out (alterability, physical indices, velocity of ultrasonic wave propagation, uniaxial compression, flection resistence, Amsler desgaste, and resistence to freezing and heating) indicated that parameters and values were identical for both granites investigated. These parameters and values are consistent with the Brazilian and international standards for siliciclastic rocks of ornamental use, as well as other Brazilian ornamental granites. The analysis of all results indicates that both the Flores and Jacarandá granites present good quality, and that they are indicated for ornamental use of revetment interior and exterior of buildings