3 resultados para thermal inertia
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Standardization and sustainability: these two apparently antagonistic words find the challenge of uniting in a flexible architectonic proposal. This was the idea that motivated the proposal of this assignment, whose appearing is bound up with the necessity of thinking about standardized spaces that attend on functional criterias and environmental sustainability, in reply to an existing real demand. The assignment consists of an architectonic proposal for a flexible standard of a Basic Unit of Health for the bioclimatic zone 7 of RN (UBS RN-7), with emphasis in the environmental sustainability. The project contemplates innumerable involved variables, such as: obedience to the current law of the Health Ministry for the UBSs; formal/aesthetic aspects; criterias of expansiveness of the UBS I for the UBS II; relative aspects to the constructive rationality and, mainly, sustainability aspects. With the intention to unite the variables and, also, glimpsing a proposal that could reach a good functional performance, aesthetic, of environment comfort and energetic efficiency, it was also necessary to consider concepts about the flexibility of the envelopment. The elaboration of the architecture first draft was based on bibliographical research, conceptual studies and references, elaboration of the architectonic program and the draft development for the UBS port I and the UBS port II. To the end, an implantation data sheet for the project is proposed for the UBS standard project, where strategies of thermal isolation, shadowing and thermal inertia are adopted and combined to three possible types of lot, resulting in 24 possibilities of implantation
Resumo:
Standardization and sustainability: these two apparently antagonistic words find the challenge of uniting in a flexible architectonic proposal. This was the idea that motivated the proposal of this assignment, whose appearing is bound up with the necessity of thinking about standardized spaces that attend on functional criterias and environmental sustainability, in reply to an existing real demand. The assignment consists of an architectonic proposal for a flexible standard of a Basic Unit of Health for the bioclimatic zone 7 of RN (UBS RN-7), with emphasis in the environmental sustainability. The project contemplates innumerable involved variables, such as: obedience to the current law of the Health Ministry for the UBSs; formal/aesthetic aspects; criterias of expansiveness of the UBS I for the UBS II; relative aspects to the constructive rationality and, mainly, sustainability aspects. With the intention to unite the variables and, also, glimpsing a proposal that could reach a good functional performance, aesthetic, of environment comfort and energetic efficiency, it was also necessary to consider concepts about the flexibility of the envelopment. The elaboration of the architecture first draft was based on bibliographical research, conceptual studies and references, elaboration of the architectonic program and the draft development for the UBS port I and the UBS port II. To the end, an implantation data sheet for the project is proposed for the UBS standard project, where strategies of thermal isolation, shadowing and thermal inertia are adopted and combined to three possible types of lot, resulting in 24 possibilities of implantation
Resumo:
Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.