47 resultados para linhas de transmissão

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Agência Nacional de Energia Elétrica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents in a simulated environment, to analyze the length of cable needed counterweight connected to ground rod, able to avoid the phenomenon of flashover return, back flashover, the insulator chains of transmission lines consisting of concrete structures when they are subjected to lightning standardized regarding certain resistivity values of some kinds of soil and geometric arrangements of disposal of grounding systems structures

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work an algorithm for fault location is proposed. It contains the following functions: fault detection, fault classification and fault location. Mathematical Morphology is used to process currents obtained in the monitored terminals. Unlike Fourier and Wavelet transforms that are usually applied to fault location, the Mathematical Morphology is a non-linear operation that uses only basic operation (sum, subtraction, maximum and minimum). Thus, Mathematical Morphology is computationally very efficient. For detection and classification functions, the Morphological Wavelet was used. On fault location module the Multiresolution Morphological Gradient was used to detect the traveling waves and their polarities. Hence, recorded the arrival in the two first traveling waves incident at the measured terminal and knowing the velocity of propagation, pinpoint the fault location can be estimated. The algorithm was applied in a 440 kV power transmission system, simulated on ATP. Several fault conditions where studied and the following parameters were evaluated: fault location, fault type, fault resistance, fault inception angle, noise level and sampling rate. The results show that the application of Mathematical Morphology in faults location is very promising

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of algorithms for fault location i n transmission lines is directly related to the accuracy of its input data. Thus, fa ctors such as errors in the line parameters, failures in synchronization of oscillographic recor ds and errors in measurements of voltage and current can significantly influence the accurac y of algorithms that use bad data to indicate the fault location. This work presents a new method ology for fault location in transmission lines based on the theory of state estimation in or der to determine the location of faults more accurately by considering realistic systematic erro rs that may be present in measurements of voltage and current. The methodology was implemente d in two stages: pre-fault and post- fault. In the first step, assuming non-synchronized data, the synchronization angle and positive sequence line parameters are estimated, an d in the second, the fault distance is estimated. Besides calculating the most likely faul t distance obtained from measurement errors, the variance associated with the distance f ound is also determined, using the errors theory. This is one of the main contributions of th is work, since, with the proposed algorithm, it is possible to determine a most likely zone of f ault incidence, with approximately 95,45% of confidence. Tests for evaluation and validation of the proposed algorithm were realized from actual records of faults and from simulations of fictitious transmission systems using ATP software. The obtained results are relevant to show that the proposed estimation approach works even adopting realistic variances, c ompatible with real equipments errors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eventually, violations of voltage limits at buses or admissible loadings of transmission lines and/or power transformers may occur by the power system operation. If violations are detected in the supervision process, corrective measures may be carried out in order to eliminate them or to reduce their intensity. Loading restriction is an extreme solution and should only be adopted as the last control action. Previous researches have shown that it is possible to control constraints in electrical systems by changing the network topology, using the technique named Corrective Switching, which requires no additional costs. In previous works, the proposed calculations for verifying the ability of a switching variant in eliminating an overload in a specific branch were based on network reduction or heuristic analysis. The purpose of this work is to develop analytical derivation of linear equations to estimate current changes in a specific branch (due to switching measures) by means of few calculations. For bus-bar coupling, derivations will be based on short-circuit theory and Relief Function methodology. For bus-bar splitting, a Relief Function will be derived based on a technique of equivalent circuit. Although systems of linear equations are used to substantiate deductions, its formal solution for each variant, in real time does not become necessary. A priority list of promising variants is then assigned for final check by an exact load flow calculation and a transient analysis using ATP Alternative Transient Program. At last, results obtained by simulation in networks with different features will be presented

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a theoretical analysis and numerical and experimental results of the scattering characteristics of frequency selective surfaces, using elements of type patch perfectly conductor. The structures are composed of two frequency selective surfaces on isotropic dielectric substrates cascaded, separated by a layer of air. The analysis is performed using the method of equivalent transmission line in combination with the Galerkin method, to determine the transmission and reflection characteristics of the structures analyzed. Specifically, the analysis uses the impedance method, which models the structure by an equivalent circuit, and applies the theory of transmission lines to determine the dyadic Green's function for the cascade structure. This function relates the incident field and surface current densities. These fields are determined algebraically by means of potential incidents and the imposition of the continuity of the fields in the dielectric interfaces. The Galerkin method is applied to the numerical determination of the unknown weight coefficients and hence the unknown densities of surface currents, which are expanded in terms of known basis functions multiplied by these weight coefficients. From the determination of these functions, it becomes possible to obtain numerical scattered fields at the top and bottom of the structures and characteristics of transmission and reflection of these structures. At work, we present numerical and experimental results for the characteristics of transmission and reflection. Comparisons were made with other results presented in literature, and it was observed a good agreement in the cases presented suggestions continuity of the work are presented

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the transmission line method is explored on the study of the propagation phenomenon in nonhomogeneous walls with finite thickness. It is evaluated the efficiency and applicability of the method, considering materials like gypsum, wood and brick, found in the composition of the structures of walls in question. The results obtained in this work are compared to those available in the literature, for several particular cases. A good agreement is observed, showing that the performed analysis is accurate and efficient in modeling, for instance, the wave propagation through building walls and integrated circuit layers in mobile communication and radar system applications. Later, simulations of resistive sheets devices such as Salisbury screens and Jaumann absorbers and of transmission lines made of metal-insulator-semiconductor (MIS) are made. Thereafter, it is described a study on frequency surface selective structures (FSS). It is proposed the development of devices and microwave integrated circuits (MIC) of such structures, for the accomplishment of experiments. Finally, future works are suggested, for instance, on the development of reflectarrays, frequency selective surfaces with dissimilar elements, and coupled frequency selective surfaces with elements located on different layers

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work proposes a new technique for phasor estimation applied in microprocessor numerical relays for distance protection of transmission lines, based on the recursive least squares method and called least squares modified random walking. The phasor estimation methods have compromised their performance, mainly due to the DC exponential decaying component present in fault currents. In order to reduce the influence of the DC component, a Morphological Filter (FM) was added to the method of least squares and previously applied to the process of phasor estimation. The presented method is implemented in MATLABr and its performance is compared to one-cycle Fourier technique and conventional phasor estimation, which was also based on least squares algorithm. The methods based on least squares technique used for comparison with the proposed method were: forgetting factor recursive, covariance resetting and random walking. The techniques performance analysis were carried out by means of signals synthetic and signals provided of simulations on the Alternative Transient Program (ATP). When compared to other phasor estimation methods, the proposed method showed satisfactory results, when it comes to the estimation speed, the steady state oscillation and the overshoot. Then, the presented method performance was analyzed by means of variations in the fault parameters (resistance, distance, angle of incidence and type of fault). Through this study, the results did not showed significant variations in method performance. Besides, the apparent impedance trajectory and estimated distance of the fault were analysed, and the presented method showed better results in comparison to one-cycle Fourier algorithm

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a study of the integration of filters and microstrip antennas, yielding devices named as filtennas for applications in wireless communications systems. The design of these structures is given from the observation of filtennas based integration between horn antennas and frequency selective surfaces (FSS), used in the band X. The choice of microstrip line structures for the development of a new configuration filtennas justifies the wide application of these transmission lines, in recent decades, always resulting in the production of circuit structures with planar light-weight, compact size, low cost, easy to construct and particularly easy to integrate with other microwave circuits. In addition, the antenna structure considered for the composition of filtennas consists of a planar monopole microstrip to microstrip filters integrated in the feed line of the antenna. In particular, are considered elliptical monopole microstrip (operating in UWB UWB) microstrip filters and (in structures with associated sections in series and / or coupled). In addition, the monopole microstrip has a proper bandwidth and omnidirectional radiation pattern, such that its integration with microstrip filters results in decreased bandwidth, but with slight changes in the radiation pattern. The methods used in the analysis of monopoles, and filters were filtennas finite elements and moments by using commercial software Ansoft Designer and HFSS Ansoft, respectively. Specifically, we analyze the main characteristics of filtennas, such as radiation pattern, gain and bandwidth. Were designed, constructed and measures, several structures filtennas, for validation of the simulated results. Were also used computational tools (CAD) in the process of building prototypes of planar monopoles, filters and filtennas. The prototypes were constructed on substrates of glass-fiber (FR4). Measurements were performed at the Laboratory for Telecommunications UFRN. Comparisons were made between simulated and measured, and found good agreement in the cases considered

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy is a vital resource for social and economic development. In the present scenario, the search for alternative energy sources has become fundamental, especially after the oil crises between 1973 and 1979, the Chernobyl nuclear accident in 1986 and the Kyoto Protocol in 1997. The demand for the development of new alternative energy sources aims to complement existing forms allows to meet the demand for energy consumption with greater security. Brazil, with the guideline of not dirtying the energy matrix by the fossil fuels exploitation and the recent energy crisis caused by the lack of rains, directs energy policies for the development of other renewable energy sources, complementing the hydric. This country is one of the countries that stand out for power generation capacity from the winds in several areas, especially Rio Grande do Norte (RN), which is one of the states with highest installed power and great potential to be explored. In this context arises the purpose of this work to identify the incentive to develop policies of wind energy in Rio Grande do Norte. The study was conducted by a qualitative methodology of data analysis called content analysis, oriented for towards message characteristics, its informational value, the words, arguments and ideas expressed in it, constituting a thematic analysis. To collect the data interviews were conducted with managers of major organizations related to wind energy in Brazil and in the state of Rio Grande do Norte. The identification of incentive policies was achieved in three stages: the first seeking incentives policies in national terms, which are applied to all states, the second with the questionnaire application and the third to research and data collection for the development of the installed power of the RN as compared to other states. At the end, the results demonstrated hat in Rio Grande do Norte state there is no incentive policy for the development of wind power set and consolidated, specific actions in order to optimize the bureaucratic issues related to wind farms, especially on environmental issues. The absence of this policy hinders the development of wind energy RN, considering result in reduced competitiveness and performance in recent energy auctions. Among the perceived obstacles include the lack of hand labor sufficient to achieve the reporting and analysis of environmental licenses, the lack of updating the wind Atlas of the state, a shortfall of tax incentives. Added to these difficulties excel barriers in infrastructure and logistics, with the lack of a suitable port for large loads and the need for reform, maintenance and duplication of roads and highways that are still loss-making. It is suggested as future work the relationship of the technology park of energy and the development of wind power in the state, the influence of the technology park to attract businesses and industries in the wind sector to settle in RN and a comparison of incentive policies to development of wind energy in the Brazilian states observing wind development in the same states under study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The organizations are characterized as dynamic spaces, they are being revisited and redefined, because they constitute structural human spaces and new vain outlines won expression. As it begins, of the non consensus in its conception, it is explicit the complexity degree that is identified in the plurality and diversity, brought by the people that compose them, characterizing it as accomplishment space, of happiness and also of conflict, of relationships of power and organizational limits and from birth and burial of faiths, values, norms, symbols, knowledge and rituals, therefore, deeply human. In that way, to know the administration of the organization is preponderant condition for the format of the human relationships to be delineated in its living. Like this the work makes an option in knowing the social administration, this work tries to know and analyze the values and beginnings of the social administration; revealling characteristics and specificities of the organizational performance of UNIPOP that contribute to the formation of the conception of Social Administration, it tends as source of the information the managers of the institution; to identify the formative values of UNIPOP that contribute to the youths' partner-political action in the community, tends for reference the current students of the organization and last to evaluate values structurates and supporting that interconnection between the organizational Administration, formation youth's program, participation and autonomy and attendance, starting from the existences gained by the exits, of that program. This way, the research will be qualitative, looking for understanding starting from their documents, the existence of those values

Relevância:

20.00% 20.00%

Publicador:

Resumo:

American visceral leishmaniasis is a zoonosis caused by Leishmania infantum and transmitted by the bite of the sand flies Lutzomia longipalpis.The main domestic reservoir is the dog, while foxes and opposums are the known wild reservoirs. However, identification of natural infections with L. infantum in rodents appears for need of investigating the participation of these rodents how source of infection of the parasite. In the present work the Leishmania infantum infection was investigated in rodents captured in Rio Grande do Norte, aiming at to offer subsidies to the understanding of the epidemic chains of LVA in the State. Thirteen Galea spixii were distributed in four groups, being G1 the group control with four animals and the others, G2, G3 and G4, with three animals each. Those animals were intraperitoneally inoculated with 107 promastigotas of L. infantum and accompanied for, respectively, 30, 90 and 180 days. Weekly the animals were monitored as for the corporal weight and rectal temperature. At the end of each stipulated period the animals were killed. Blood were used for determination of the parameters biochemical and haematological, PCR, ELISA, microscopic examination and cultivation in NNN medium. Liver, spleen and lymph node were used in Giemsa-stained impression and cultivation in NNN medium. Liver and spleen fragments were still used in PCR and histopathological, respectively. At the same time 79 rodents of the species Rattus rattus, Bolomys lasiurus, Oligoryzomys nigripis, Oryzomys subflavus and Trichomys apereoides were captured in the Municipal districts of Brejinho, Campo Grande, Coronel Ezequiel, Passa e Fica and Vázea for identification of natural infection with L. infantum. Evidence of infection was checked by direct examination of Giemsa-stained impression of liver, spleen and blood and culture of these tissues in NNN medium. Antibodies were researched by ELISA. They were not found differences among the weigh corporal final, rectal temperature and biochemical and haematological parameters of the Galea spixii controls and infected. The rectal temperature of the animals varied from 36OC to 40OC. For the first time values of the haematocrit (33,6% to 42,8%), hemoglobin (10,2 to 14,5g/dl), erythrocyts number (4,67x106 to 6,90x106/mm3), total leukocytes (0,9x103 to 9,2x103/mm3), platelets (49x103 to 509x103/mm3) total proteins (1,56 to 6,06 g/dl), albumin (1,34 to 3,05 g/dl) and globulins (0,20 to 3,01 g/dl) of the Galea spixii were determined. The lymphocytes were the most abundant leucocytes. Infection for L. infantum was diagnosed in two animals euthanasied 180 days after the infection. In one of the animals was also identified antibodies anti-Leishmania. The parasite was not found in none of the five other species of rodents captured. Galea spixii are resistant to the infection for L. infantum and they are not good models for the study for visceral leishmaniose, although they can act as infection sources. More studies are necessary to determine the paper of the rodents in the epidemic chain of transmission of the visceral leishmaniose in the State of Rio Grande do Norte