7 resultados para ingestas recomendadas

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Masters degree dissertation presents a research that aims at analyzing the activities regarding within a hotel managers work in Natal/RN - Brazil, This Masters degree dissertation presents the research that aims at analyzing the activities regarding the hotel managers work in Natal / RN - Brazil, performing diagnosis of their activities and relating the aspects that impact the quality and productivity of hotel services and managers occupational health. This research is characterized as a case study with a qualitative approach, taking the method of Ergonomic Work Analysis which is the analysis of the managers work activity as a reference to the focus; and combining the use of observational and interactional methods. Ergonomics and macroergonomics are used in this study not only to understand the physical, cognitive and organizational constraints of the manager s duties, but also to characterize the work organizational architecture and design of that hotel. High workload, accumulation of tasks and diversion of functions performed by managers were noticed, increasing thereby the physical and psychological suffering for them. It was found that the activity of managers is characterized by the ambivalence of power, limited autonomy, cooperation, interdependence between managers and the fear of incompetence. It was also noticed that managers devote more time to the day job (37%), another time to sleep (30%), while only 33% of the rest of the day are meant for activities like taking care of health, family, social life and study. Although there are few studies addressing the health and safety of hotel managers, this research revealed that 84% of the surveyed hotel managers complain of musculoskeletal pain which 50% are obese and are 100% sedentary. It was also observed that managers adopt unsuitable postures for carrying out the work activities that contribute to becoming injured or work-related musculoskeletal disorders in the near future. Ergonomic measures were recommended as an investment in the skills and the training of managers, encouraging cooperative work, appropriateness of workload, limiting overtime, preserving the enjoyment of breaks during work and weekly holidays, changing the layout of the work sector , usage of communication technology to prevent displacement, compensatory physical activities, furniture adaptation, among others

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The farm’s rural dwellings of creation from the Seridó Potiguar microregion, built in the nineteenth century, became a reference by its vernacular character, i.e. these buildings, besides having recognized relevance to the identity of the region, they are adapted to the conditions of the place in many aspects (economic, cultural, construction, physical, et.) and consist in protective spaces in relation to hostile characteristics of Seridó’s climate. Considering the above premise, the following question arises: What characteristics of the nineteenth century Seridó Potiguar’s cattle farms are crucial for them to be a protective space in relation to the semiarid climate? In order to answer the question, this research aim to identify which particularities of the Seridó’s farmhouses that contribute to adaptability in these buildings to semiarid climate, as protection environments; and contribute to the stock valuation of the architectural heritage concerned. Therefore, procedures were adopted divided into two stages. Were first identified the recurring characteristics in the studied buildings, through typological study performed from existing inventories (DINIZ, 2008; FEIJÓ, 2002; IPHAN, 2012). To define the type it worked up with the concept that merges Durand’s analytical typology that identifies the similarities and differences to classify buildings, having the character of historical survey and architectural documentation, with the definition proposed by Argan (1963) that the type is not defined a priory, but the deduction from a number of illustrative cases which have formal and functional similarity with each other. Then worked up in a sample of five different types with each other, defined by the possibility of access to the interior of the houses, proximity to other copies, good state of conservation and preservation. The contemplated farms were: Pitombeiras, Agenus e Garrotes in Acari’s town, and the municipality of Caicó, Palma and Penedo. The second stage consists of the architectural survey, photographic record, digital three-dimensional modeling (aiming to expand the existing documentation and registration) and thermal monitoring over approximately a representative day in five farmhouses, relating the thermal performance of the houses with their individual characteristics. The selected variables for analysis monitoring are based on the thermal comfort adaptive model (SPAGNOLO and DE DEAR, 2003 apud NEGREIROS, 2010). The characteristics of the houses were analyzed as meeting the passive thermal conditioning strategies recommended by NBR 15220 (ABNT, 2005), for the bioclimatic zone 7 where the municipalities of Caicó and Acari are located. The house’s analysis of the operating temperatures revealed that 90% of the times of day the environments are within the comfort range. The farmhouses, which had a higher degree of compliance with recommended bioclimatic strategies, had the best thermal performance. In environments (usually the kitchen and rooms with low ceiling heights, exposed to west radiation) which still had discomfort hours, the thermal comfort can be reached with air movement approximately 1,0 m/s.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The farm’s rural dwellings of creation from the Seridó Potiguar microregion, built in the nineteenth century, became a reference by its vernacular character, i.e. these buildings, besides having recognized relevance to the identity of the region, they are adapted to the conditions of the place in many aspects (economic, cultural, construction, physical, et.) and consist in protective spaces in relation to hostile characteristics of Seridó’s climate. Considering the above premise, the following question arises: What characteristics of the nineteenth century Seridó Potiguar’s cattle farms are crucial for them to be a protective space in relation to the semiarid climate? In order to answer the question, this research aim to identify which particularities of the Seridó’s farmhouses that contribute to adaptability in these buildings to semiarid climate, as protection environments; and contribute to the stock valuation of the architectural heritage concerned. Therefore, procedures were adopted divided into two stages. Were first identified the recurring characteristics in the studied buildings, through typological study performed from existing inventories (DINIZ, 2008; FEIJÓ, 2002; IPHAN, 2012). To define the type it worked up with the concept that merges Durand’s analytical typology that identifies the similarities and differences to classify buildings, having the character of historical survey and architectural documentation, with the definition proposed by Argan (1963) that the type is not defined a priory, but the deduction from a number of illustrative cases which have formal and functional similarity with each other. Then worked up in a sample of five different types with each other, defined by the possibility of access to the interior of the houses, proximity to other copies, good state of conservation and preservation. The contemplated farms were: Pitombeiras, Agenus e Garrotes in Acari’s town, and the municipality of Caicó, Palma and Penedo. The second stage consists of the architectural survey, photographic record, digital three-dimensional modeling (aiming to expand the existing documentation and registration) and thermal monitoring over approximately a representative day in five farmhouses, relating the thermal performance of the houses with their individual characteristics. The selected variables for analysis monitoring are based on the thermal comfort adaptive model (SPAGNOLO and DE DEAR, 2003 apud NEGREIROS, 2010). The characteristics of the houses were analyzed as meeting the passive thermal conditioning strategies recommended by NBR 15220 (ABNT, 2005), for the bioclimatic zone 7 where the municipalities of Caicó and Acari are located. The house’s analysis of the operating temperatures revealed that 90% of the times of day the environments are within the comfort range. The farmhouses, which had a higher degree of compliance with recommended bioclimatic strategies, had the best thermal performance. In environments (usually the kitchen and rooms with low ceiling heights, exposed to west radiation) which still had discomfort hours, the thermal comfort can be reached with air movement approximately 1,0 m/s.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems