5 resultados para implant-supported prosthesis

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.