3 resultados para heart ventricle isometric contraction

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fluctuacion force has been increasingly used in studies with elderly as a good predictor of performance and functionality of the motor. However, most analyzes the fluctuation of force in one session. Thus, identifying the minimum amount of sessions needed for familiarization with the fluctuation strength in isometric exercise become relevant. Furthermore, to investigate the effects of applying transcranial direct current stimulation (tDCS) associated with regular exercise on rates fluctuation task force is extremely important. In the first experiment, volunteers were subjected to a protocol marked by a familiarization session to establish the parameters of VCM and eight sessions with intensity of 30% MVC in office. It was observed that two familiarization sessions are required so there is a fluctuation stabilizing force. In experiment II, subjects performed an isometric contraction before and after applying tDCS (cathode, anode and sham) applied to M1. ETCC anodic effectively contributed to reducing the fluctuation of force during isometric exercise in the elderly, while the cathodic caused the increased levels of strength fluctuation. It was concluded that there is a need to implement a familiarization protocol with at least two sessions to avoid possible misunderstandings of measurements in tests of fluctuacion force. Besides that tDCS interfered with the behavior of the oscillations of force, with cathodic promoting increased fluctuation strength and anodic contributed to greater stability, demonstrating the potential of this technique neuromodulation associated with exercise as rehabilitation tools

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To examine the acute effects caused by three techniques for stretching the hamstrings muscle on the active concentric peak torque (PT), passive PT and electromyographic activity (EMG). METHODS: Sixty volunteers (mean ± SD age, 22.6 ± 3 years), height 1.64 ± 0.07m and body weight of 58 ± 8.6kg, were randomly allocated into 4 groups of 15 subjects: Control Group (CG) - 5 minutes at rest, Static Stretching Group (SG) - 2 x 30s; Hold-Relax Group (HRG) - 3 x 6s of isometric contraction of hamstrings interspersed by 10s of hamstrings stretching and agonist Hold-Relax Group (AHRG) - 3 x 6s of isometric contraction of the quadriceps interspersed by 10s of hamstrings stretching. Evaluation has been conducted preand post-intervention, which verified the active concentric PT, passive PT EMG activity of IT. The statistical inference was performed by testing intra and inter, significance level at 5%. RESULTS: After intervention, there was a reduction in passive PT on CG, accompanied by a reduction of EMG activity, and an increase in passive PT on SG and AHRG. There was no change in the active concentric PT, or change in EMG activity. CG showed an increase in angle of the PT active, while the other groups showed no change. CONCLUSION: The results suggest that the shortterm stretching: 1) causes acute increase in passive torque, since the muscle does not perform sub-maximal contraction, 2) does not change in electromyographic activity and active torque, ind ependent of the technique

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim : To evaluate and to standardize surface electromyography (sEMG) normalization procedures for respiratory muscles by comparing muscle activation during Maximal Voluntary Isometric Contraction (MVIC) and Maximal Respiratory Pressures (MIP, MEP and sniff test). Methods: Healthy subjects were evalua ted regarding demographics, spirometry and sEMG during the five maneuvers: sniff test, MIP , MEP and Maximal Voluntary Isometric C ontraction (MVIC) of RA, SCM and SC A . For electrode placement, skin was prepared with abrasion, followed by shaving in the foll owing regions for acquisition of el ectromyographic signals: (1) SC M: lower third of the distance between the mastoid process and t he sternoclavicular joint; (2) SC A : 5 cm to the right from the sternoclavicular joint and at this point, up to 2 cm; and (3 ) RA: the level of umbilicus, 4 cm to the right. In electromyographic variables analysis , the data normality was assessed by Shapiro - Wilk test. Comparisons among studied maneuvers were performed by Friedman Test and Dunn’s post - hoc for multiple comparisons a mong inspiratory maneuvers, and Mann Whitney test for expiratory maneuvers. Subgroups differences between genders were performed by Student's t test or Mann - Whitney test according to data normality. Results: 35 subjects participated in the study, b ut 5 we re excluded (BMI> 25 kg/ m²). Sample consisted of 30 subjects (1 5 women), mean age 27.3±7.43 years, BMI 22.2 ± 1.69 kg/m² and spirometric indices within normal limits. Specific MVIC for SCM, SCA and RA showed the highest RMS. When we grouped sample into gender we found no difference among RMS values for the studied SCM maneuvers, while for SCA, MVIC SCM / SCA was the one with the highest RMS and for RA, MVIC RA in men. Once considering women, MVIC SCM/SCA showed the highest RMS for SCM, SCA and MVIC RA showed t he highest value for RA. Conclusion: MVIC for SCM, SCA and RA muscles showed the highest RMS values. When comparing RMS between the studied groups, there was no significant difference between men and women.