Resumo:

The great demand for Federal Institutions of High Education (IFES) design, triggered by the favourable political moment, boosts the public works market and brings with it the stigma of seeking the lowest cost and meet the federal Law 8.666/93 (Bids). In this context, this research makes an analysis of compliance with Fire Safety’s normative requirements in IFES’s architectural designs, taking this point as an evaluation of quality of designs. For the study, were used, IFES’s designs, specifically from UFERSA – Universidade Federal Rural do Semiárido and UFRN – Universidade Federal do Rio Grande do Norte, selected by the relationship use x public served and yet, in the replication of these buildings’ construction. The research was developed through the identification of the Fire Safety applicable legislation to the designs in question, with the determination of the demanded conditions that are architect’s autonomy or that affect the architectural design. Tabulated the requirements, through data collection and measures gathered in the blueprints, was made a comparison and verification of the compliance with these. The results of this evaluation reveal that the minimum requirements was not fulfilled and that IFES’s architectural designs, taken as object in this study, certainly will suffer restrictions in their regularization process with the Fire Department. It is concluded that is necessary an improvement in the IFES’s designs to meet the minimum fire safety regulations and improvement in quality. Moreover, the results direct to the understanding that level of knowledge about Fire Safety received in undergraduate by architects is insufficient for appropriate elaboration of architectural designs in this area.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.