57 resultados para desenho de próteses

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to analyze and evaluate the Urban furniture designed to public areas according to the Revitalization planning for Rio Grande do Norte coastland, defining visual relations among urban elements in the landscape of revitalized public urban areas with cultural, paisagistic and touristic values and the design process used for developing urban furniture to those areas, observing the incoming consequences use to that process in a specific urban context which alters use, functions, cultural images as well as social values attributed to each particular place. Environmental perceptions, legibility of local cultural references and their representation through the design of urban elements, act in a positive or negative manner over the inhabitants cognition process of some particular revitalized area, determining new use and attributions to those areas. Designs for coastal urban interventions try excessively to standardize technical media, construction materials and planning configurations, creating artificial sceneries that segregates users, imposing new structures and usage, generating, consequently, the so called non-places and burlesque regionalism. The research is divided into 4 chapters: 1) Theoretical support (Industrial design; Urban furniture; Public urban spaces; Urban image and environmental perception; Urban occupation and interventions in coastland areas); 2) Methodological procedures and data collection; 3) Analysis of Rio Grande do Norte coastal areas and their urban interventions; 4) Final considerations and Industrial Design contributions to the subject

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At present, the material of choice for performing aesthetic dental prosthetic work is in the ceramic. Among them, the ceramic base of stabilized zirconia with 3% yttria (3Y - TZP) stand out for having excellent physical and mechanical properties. During the machining of blocks of zirconia in the laboratory to prepare the various types of prostheses, much of the material is given off in the form of powder, which is subsequently discarded. The waste of this material results in financial loss, reflecting higher final cost treatment for patients, as well as damage to the environment, thanks to the processes involved in the manufacture and disposal of the ceramic. This research, pioneered the recycling of zirconium oxide powder obtained during milling of dental crowns and bridges, we highlight the social and environmental aspects and aims to establish a protocol for the reuse of waste (powder of zirconia Zirkonzahn® system) discarded to obtain a new block of compacted zirconia to maintain the same mechanical and microstructural properties of commercial high-cost imported material. To compare with the commercial material, samples were uniaxially (20 MPa) and isostatically (100 MPa), and its mechanical and microstructural characterization was performed through tests of density, porosity, dilatometry, X-ray diffraction (XRD), hardness, fracture toughness, resistance to fracture electron microscopy (SEM) and analysis of grain size. The results observed in the samples were isostatically pressed similiares those obtained with samples from the commercial material demonstrating the viability of the process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To think about a school that is for everyone has been a challenge for many people connected to education worldwide demanding from researchers of each level of knowledge an association to such effort. The study presented on this paper unites itself to the voices, movements and researches of these scholars, seeking to contribute on building possibilities on which mathematics can be thought and worked on schools in order for every student to learn, whether they have some sort of deficiency, disorders, syndromes or not. This essay has the goal to investigate the possibilities of inclusive pedagogical practices mediated by math games with rules, developed and used throughout the Universal Design perspective; a qualitative research took place with a collaborative methodology that involved managers, teachers and students from a public school situated on the city of Natal/Brazil. On the investigation math games with rules were developed and made according to the Universal Design concept, starting from initial studies which articulated theoretical groundings to the reality of school and the teacher s conceptions. After that, classes using these tools were planned collectively which oriented inclusive pedagogical practices of classes from the 1st to the 4th year of elementary school. Throughout the process many instruments such as: tape recording, video footages, notes from the researcher; the teachers and the students were used for constant work evaluation and also to record the research data. In the end, the data indicated effective contributions of the mediated pedagogical practices by games with rules under the perspective of Universal Design for Inclusive Mathematics Education

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the historical-cultural perspective, the drawing is processed by means of a shared and complex way, under diverse relations with the other and with the immersed signs of the culture. That is, something constituted by the social interactions and that can modify the structure of the psychological functions, therefore as socialized sign, propitiates the incorporation of the functions socially. In this way, the figuration carrier sensitive and established meanings historically disclosing the shared experiences and the ways of the subject to think and perceive the world. Such reflections gave shape to the main problem of this research: how to think over about the drawing at the school to incide in the reconstruction of the childs imaginative language? Under such perspective, this work deals with the interactions in the production process of the drawing of the children in a context of teach-Iearning of the elementary school having as goal to analyze the interactions established in the cIassroom in the process of production of the drawings; to propose situations of learnings that favor the advance graphical expression of the students; and to identify in the interactive games some relations between body expression and drawing. For its accomplishment, it was opted for the construction process based in the collaborative investigation by the fact to propitiate negotiations, sharing and confrontation of ideas, becoming possible a joint construction of the knowledge. For this research, the researcher and the collaborating teacher, as well as the involved children, become themselves into co-authors of the context studied. As locus of the research, it was chosen a first cycle class, with 30 students, from Municipal School Profª. Emília Ramos (Natal/RN - Brazil), whose election took in account the fact of this school to constitute in a promotional space of reflections and professional development of teachers in service and, at the same time, for presentinglimitations theoretic- methodological in the field of teaching for Arts. In the process of the research, it was perceived that the children with the support of the verbal language formulates meanings on the seen and imagined object, printing lines and forms that if overlap to the physiological aspects of the visual perception. That is, the drawing discloses a reality appraised, enriched for the picked up vision of the image, but the meanings established for the author, or observer who becomes it perceivable and identified. In the systemizing situations, it was observed that the teaching-Iearning process of the drawing, implies a co-construction between teachers and learners. And, moreover, the necessity to interlace emotion and cognition by means of plastic-corporal interactions that foment drawing experiences, whose process concurs for the imagenative reconstruct of the apprentices

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the development of Bobbin Lace and Design workshops, in the neighborhood of Vila de Ponta Negra (in Natal - RN, Brazil), which proposed contents and practices for its learning and teaching that would compose a possible model for a hybrid Workshop of Bobbin Lace and Lace Design. This research was based on Ergonomic Work Analysis, a methodology used by Ergonomics to analyze work in a wide approach, considering cognitive, social, organizational, as well as other aspects which are relevant to the study of the working situation, in terms of learning/teaching, as addressed on this paper. Some steps of the above mentioned methodology were followed in order to understand the activity of Bobbin Lace craftswomen, by means of bibliographical research centered on this activity. The instruments used for collecting data comprise of conversational actions, analysis of collective work, and spontaneous as well as provoked verbalizations. The adaptations performed in the process of learning/teaching Bobbin Lace for the achievement of Bobbin Lace and Design workshops became instrumental for the continuity of that tradition, attracting new apprentices to this art/craft causing to revitalize a network of handicraft economical activities linked to the Bobbin Lace production, such as the making of cushion, bobbins and trestles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bobbin lace, a secular art in the process of extinction in the Village Ponta Negra in Natal, Brazil, was one of the main means of income generation for some families in town, but over time, there was growing disaffection of the younger generation to learn and practice this art, due to the high demand of time for production and insufficient and not guaranteed financial return . This project aims to promote the recovery of control over the product in the production of bobbin lace in the village of Ponta Negra, by design and implementation of a workshop for the transfer of drawing techniques in the Production Center of Craft in Village of Ponta Negra. This design was based on the methodology of Ergonomic Work Analysis and in the concepts of anthropotechnology and technology social. The ergonomic analysis, by advocating and enforcing the social and technical building, was essential for the modeling of this workshop, as allowed the construction of a social participative device , with the participation of the community groups and the external group of researchers, in a process of social construction technique. As a result, it was observed that the transfer of technical design of bobbin lace molds came to complement the learning of art office, providing solutions to promote the sustainable development of the group of tenants, in an attempt to reduce the risk of extinction eminent, and also contributed to reactivate a network of economic activities interconnected to the craft, such as the production of cushions, lace and easels

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manufacturing of above and below-knee prosthesis starts by taking surfac measurements of the patient s residual limb. This demands the making of a cartridg with appropriate fitting and customized to the profile of each patient. The traditiona process in public hospitals in Brazil begins with the completion of a record file (according to law nº388, of July 28, 1999 by the ministry of the health) for obtaining o the prosthesis, where it is identified the amputation level, equipment type, fitting type material, measures etc. Nowadays, that work is covered by the Brazilian Nationa Health Service (SUS) and is accomplished in a manual way being used commo measuring tapes characterizing a quite rudimentary, handmade work and without an accuracy.In this dissertation it is presented the development of a computer integrate tool that it include CAD theory, for visualization of both above and below-knee prosthesis in 3D (i.e. OrtoCAD), as well as, the design and the construction a low cos electro-mechanic 3D scanner (EMS). This apparatus is capable to automatically obtain geometric information of the stump or of the healthy leg while ensuring smalle uncertainty degree for all measurements. The methodology is based on reverse engineering concepts so that the EMS output is fed into the above mentioned academi CAD software in charge of the 3D computer graphics reconstruction of the residualimb s negative plaster cast or even the healthy leg s mirror image. The obtained results demonstrate that the proposed model is valid, because it allows the structura analysis to be performed based on the requested loads, boundary conditions, material chosen and wall thickness. Furthermore it allows the manufacturing of a prosthesis cartridge meeting high accuracy engineering patterns with consequent improvement in the quality of the overall production process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work consists of the conception, developing and implementation of a Computational Routine CAE which has algorithms suitable for the tension and deformation analysis. The system was integrated to an academic software named as OrtoCAD. The expansion algorithms for the interface CAE genereated by this work were developed in FORTRAN with the objective of increase the applications of two former works of PPGEM-UFRN: project and fabrication of a Electromechanincal reader and Software OrtoCAD. The software OrtoCAD is an interface that, orinally, includes the visualization of prothetic cartridges from the data obtained from a electromechanical reader (LEM). The LEM is basically a tridimensional scanner based on reverse engineering. First, the geometry of a residual limb (i.e., the remaining part of an amputee leg wherein the prothesis is fixed) is obtained from the data generated by LEM by the use of Reverse Engineering concepts. The proposed core FEA uses the Shell's Theory where a 2D surface is generated from a 3D piece form OrtoCAD. The shell's analysis program uses the well-known Finite Elements Method to describe the geometry and the behavior of the material. The program is based square-based Lagragean elements of nine nodes and displacement field of higher order to a better description of the tension field in the thickness. As a result, the new FEA routine provide excellent advantages by providing new features to OrtoCAD: independency of high cost commercial softwares; new routines were added to the OrtoCAD library for more realistic problems by using criteria of fault engineering of composites materials; enhanced the performance of the FEA analysis by using a specific grid element for a higher number of nodes; and finally, it has the advantage of open-source project and offering customized intrinsic versatility and wide possibilities of editing and/or optimization that may be necessary in the future