3 resultados para computer application

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Millon describes the normal personality by means of adaptation styles that are effective in normal environments and personality disorders such as unadapted operating styles. To operacionalize his theoretical model, Millon has built several instruments, including the Millon Clinical Multiaxial Inventory III (MCMI-III), wich consists of a self report inventory composed by 175 true or false response items, containing four verification scales, and others scales wich evaluates 14 personality patterns and 10 clinical syndromes. The Substance Dependence scale (T) is placed along with Clinical Syndromes scales. This research is justified by the lack of a Brazilian instrument to assess personality psychopathological aspects, and aims to translate and semantically adapt the MCMI-III to the Brazilian context, checking validity elements of the Substance Dependence scale, and developing a computer application for assisting the evaluation of assessment results. To this intent, 2.588 individuals data was collected, male and female, aged between 18 and 85 years, characterized as belonging to a clinical or non-clinical group, who took part in the survey via the internet or in person. Respondents completed the MCMI-III, a socio-demographic questionnaire and a subgroup also answered to the Goldberg General Health Questionnaire (GHQ). Besides descriptive statistics, we performed the analysis using the Student t test, principal components analysis and internal consistency. Despite difficulties related to translating very specific English terms, the assessment by judges, experts on Millon´s theory, and the back translation, attested the adequacy of the Brazilian version. Factorial analysis indicated the grouping of translated T scale items into three factors (social activities prejudice, lack of impulse control, and oppositional behavior), by presenting a single item on a fourth factor (apparently related to seeking pleasurable stimuli). The Cronbach alpha for this set of items was 0,82, indicating an acceptable scale reliability. The data analysis resulted in distinction of scores between clinical and non-clinical groups and between men and women; the relationship between high scores on the scale T and the other scales; scores of drug users according to the declared used substance; and the relationship between high scores on T and the verification of disorder or risk on GHQ mental health factor, indicating the instrument´s adequate sensistivity in identifying psychopathologies and the relationship between the different disorders or psychopathological personality patterns. Although further studies are necessary to develop the scores transformation factors, the computerized correction tool was adequate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity