5 resultados para cold-water corals

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A significant fraction of the hydrocarbon reserves in the world is formed by heavy oils. From the thermal methods used to recovery these resources, Steamflooding has been one of the main economically viable alternatives. In Brazil, this technology is widely used by Petrobras in Northeast fields. Latent heat carried by steam heats the oil in the reservoir, reducing its viscosity and facilitating the production. In the last years, an alternative more and more used by the oil industry to increase the efficiency of this mechanism has been the addition of solvents. When co-injected with steam, the vaporized solvent condenses in the cooler regions of the reservoir and mixes with the oil, creating a low viscosity zone between the steam and the heavy oil. The mobility of the displaced fluid is then improved, resulting in an increase of oil recovery. To better understand this improved oil recovery method and investigate its applicability in reservoirs with properties similar to those found in Potiguar Basin, a numerical study was done to analyze the influence of some operational parameters (steam injection rate, injected solvent volume and solvent type) on oil recovery. Simulations were performed in STARS ("Steam, Thermal, and Advanced Processes Reservoir Simulator"), a CMG ("Computer Modelling Group") program, version 2009.10. It was found that solvents addition to the injected steam not only anticipated the heated oil bank arrival to the producer well, but also increased the oil recovery. Lower cold water equivalent volumes were required to achieve the same oil recoveries from the models that injected only steam. Furthermore, much of the injected solvent was produced with the oil from the reservoir

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of the maps obtained from remote sensing orbital images submitted to digital processing became fundamental to optimize conservation and monitoring actions of the coral reefs. However, the accuracy reached in the mapping of submerged areas is limited by variation of the water column that degrades the signal received by the orbital sensor and introduces errors in the final result of the classification. The limited capacity of the traditional methods based on conventional statistical techniques to solve the problems related to the inter-classes took the search of alternative strategies in the area of the Computational Intelligence. In this work an ensemble classifiers was built based on the combination of Support Vector Machines and Minimum Distance Classifier with the objective of classifying remotely sensed images of coral reefs ecosystem. The system is composed by three stages, through which the progressive refinement of the classification process happens. The patterns that received an ambiguous classification in a certain stage of the process were revalued in the subsequent stage. The prediction non ambiguous for all the data happened through the reduction or elimination of the false positive. The images were classified into five bottom-types: deep water; under-water corals; inter-tidal corals; algal and sandy bottom. The highest overall accuracy (89%) was obtained from SVM with polynomial kernel. The accuracy of the classified image was compared through the use of error matrix to the results obtained by the application of other classification methods based on a single classifier (neural network and the k-means algorithm). In the final, the comparison of results achieved demonstrated the potential of the ensemble classifiers as a tool of classification of images from submerged areas subject to the noise caused by atmospheric effects and the water column

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This dissertation presents a methodology to the optimization of a predial system of cold water distribution. It s about a study of a case applied to the Tropical Buzios Residential Condominium, located in the Búzio s Beach, Nísia Floresta city, the east coast of the Rio Grande do Norte state, twenty kilometers far from Natal. The design of cold water distribution networks according to Norm NBR 5626 of the ABNT - Brazilian Association of Techniques Norms, does not guarantee that the joined solution is the optimal solution of less cost. It s necessary the use of an optimization methodology, that supplies us, between all the possible solutions, the minimum cost solution. In the optimization process of the predial system of water distribution of the Tropical Búzios Condominium, is used Method Granados, that is an iterative algorithm of optimization, based on the Dynamic Programming, that supplies the minimum cost s network, in function of the piezometric quota of the reservoir. For the application of this Method in ramifies networks, is used a program of computer in C language. This process is divided in two stages: attainment of the previous solution and reduction of the piezometric quota of headboard. In the attainment of the previous solution, the minors possible diameters are used that guarantee the limit of maximum speed and the requirements of minimum pressures. The piezometric quota of headboard is raised to guarantee these requirements. In the second stage of the Granados Method, an iterative process is used and it objective is to reduce the quota of headboard gradually, considering the substitution of stretches of the network pipes for the subsequent diameters, considering a minimum addition of the network cost. The diameter change is made in the optimal stretch that presents the lesser Exchange Gradient. The process is locked up when the headboard quota of desired is reached. The optimized network s material costs are calculated, and is made the analysis of the same ones, through the comparison with the conventional network s costs

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Building installations of cold water are key parts in any model of housing, are homes or condos. However, these systems are subject to failure, which can range from a leak in a device until faults in the structure of water reservoirs and distribution system. These faults are responsible for great economic and environmental costs. In order to reduce these losses, this work proposes the development of a system able to detect the presence and identify some types of water leaks that may occur. For implementation and testing, consumption model was used in a simulator capable of reproducing a similar behavior to a real model and its consequent failures. The detection of leaks is done based on an expert like model having two detection modules, one active and one passive, which use an array of sensors and actuators (valves) to do the sensing. For testing and implementation has been developed a software capable of coupling the system simulator and detector. From the results it can be seen that the system proposed in this work, as well as functioning satisfactorily, can be easily implemented in microcontrollers or embedded systems due to its simplicity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A significant fraction of the hydrocarbon reserves in the world is formed by heavy oils. From the thermal methods used to recovery these resources, Steamflooding has been one of the main economically viable alternatives. In Brazil, this technology is widely used by Petrobras in Northeast fields. Latent heat carried by steam heats the oil in the reservoir, reducing its viscosity and facilitating the production. In the last years, an alternative more and more used by the oil industry to increase the efficiency of this mechanism has been the addition of solvents. When co-injected with steam, the vaporized solvent condenses in the cooler regions of the reservoir and mixes with the oil, creating a low viscosity zone between the steam and the heavy oil. The mobility of the displaced fluid is then improved, resulting in an increase of oil recovery. To better understand this improved oil recovery method and investigate its applicability in reservoirs with properties similar to those found in Potiguar Basin, a numerical study was done to analyze the influence of some operational parameters (steam injection rate, injected solvent volume and solvent type) on oil recovery. Simulations were performed in STARS ("Steam, Thermal, and Advanced Processes Reservoir Simulator"), a CMG ("Computer Modelling Group") program, version 2009.10. It was found that solvents addition to the injected steam not only anticipated the heated oil bank arrival to the producer well, but also increased the oil recovery. Lower cold water equivalent volumes were required to achieve the same oil recoveries from the models that injected only steam. Furthermore, much of the injected solvent was produced with the oil from the reservoir