4 resultados para central venous catheterization

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a study descriptive cross-sectional and quantitative approaches, which aimed to analyze the association between hospital infection rate for insertion, maintenance of central venous catheter and the breakdown of protocols (rules and routines) by health professionals assisting patients in the ICU of a university hospital in Natal / RN. The process of data collection was through observation with structured form, refers to medical records and structured questionnaires with health professionals. The results were organized, tabulated, categorized and analyzed using SPSS 14.0. The characterization of the subjects was performed using descriptive and inferential statistics, taking into account the nature of the variables, with analysis of variance (ANOVA) and Spearman correlation test, it was a discussion of the information obtained, considering the mean, standard deviation, coefficient of variance and standard error. The variables that showed a higher level of correlation were treated with the application of significance tests. As the results, 71% of participants were female and 29% male, age ranged from 18 to 85 years (52.6 ± 22.5). The insertion, there was a variation from 0 to 5 errors (1.2 ± 1.4), during maintenance, the average was 2.3 ± 0.9 errors, ranging from 0 to 4. During the insertion and maintenance of CVC, patients who had been an infection ranging from 2 to 9 mistakes (4.2 ± 1.7), since those who did not show the variation goes from 0 to 5 errors (2, 8 ± 1.5). The correlation coefficient between the risk of infection throughout the process and the risk of infection at the insertion showed strong and significant (r = 0.845 p = 0.000) and in relation to risk of infection in maintenance was moderate and significant (r = 0.551 p = 0.001). The mistakes made by professionals in the procedures for insertion and maintenance of the catheter, associated with other conditions, shown as a risk factor for the of IH

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent decades, the search for quality care has been widely discussed by the institutions and health professionals. In this context, it is the nurse coordinator of the process of providing nursing staff, reflecting the commitment to quality of care. In this process, it is the appearance of Infections Related to health care and its potential association with the workload in nursing as a valuable indicator of quality of care. Thus, this research contributes to studies to characterize the demand of nursing work to promote a safe healthcare practice. This study aimed to identify the association of nursing workload with the number of cases of Ventilator-Associated Pneumonia, urinary tract infection and central venous catheter infection in the intensive care unit. This is a quantitative research approach, descriptive, cross-sectional and prospective, held at Unimed Hospital in Natal-RN. The study population consisted of all patients treated in the Intensive Care Unit, Hospital for a period of 90 consecutive days in 2011. The convenience sample was compostapelos patients admitted to the ICU during the period of data collection, a total sample of 286 patients. To perform the data analysis software were used: Statistica 6.0, SPPS (Statistical Package for Social Sciences) version 17.0 (2004) and Excel 2007. In the descriptive analysis, we used Measures of Central Tendency and Measures of Dispersion or Variability and the use of nonparametric tests. Of the 286 patients, 88 were from the ICU and 198 ICU II II. Males predominated in the ICU I (51.1%) and female ICU II (57.6%) patients in the ICU I were aged 61-80 years (39.8%) followed by greater than 80 years (39.8%). In the ICU II, most of the patients were aged 61-80 years (38.9%) and then from 41 to 60 years (24.2%). In relation to the class of TISS inlet predominant class II in the two ICUs (59.1%), followed by Class III also in the two units (34.6%). Most patients (70.6%) out of the ICUs belonging to class II TISS. In the ICU I, the average number of forms of the TISS 28 was 6, has in ICU II this value drops to 3.2 forms. The overall mean was 19.9 TISS points in ICU patients I and ICU II.the 17 points in the average hours required to provide adequate nursing care to patients in the ICU I found that is 10 , 7 hours, and the ICU II 9.2 hours. It was found that the time provided by the nursing staff were higher in ICU II, with an average of 19 hours available for nurses in this sector. In the ICU I, which showed higher need of available hours, it was found that the mean value of 12.7 available hours. It was found that only 2.4% of patients had these units Ventilator-Associated Pneumonia, 1.0% were infected central venous catheter and 1.4% of patients had urinary tract infection. Infection associated with health care occurs, on average, on the tenth day of hospitalization. In the ICU II, this average value extends to the twelfth day with an excess of 2.7 hours of nursing care while in ICU I value decays to the ninth day of hospitalization with a deficiency of 12-hour assistance. It is concluded that patients generally showed a need for classification of semi-intensive care and has been assisted in their need to load. As for his association with the Related Infections Health will assist this analysis could not be performed due to the small number of notifications in this period. It is suggested further study how other factors related to infections me a longer period of analysis

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trasnversal study, with the objective of evaluating the accuracy of clinical indicators of nursing diagnosis excessive fluid volume in patients undergoing hemodialysis. The study occurred in two stages, the first consisted of the evaluation of the diagnostic indicators in study; and the second, the diagnostic inference conducted by nurse diagnosticians. The first stage occurred from december 2012 to april 2013, in a University Hospital and a Hemodialysis Clinic in Northeastern of Brazil, with a sample of 100 chronic renal failure patients on hemodialysis. The data were selected through an interview form and a physical examination, organized into spreadsheets and analyzed as to the presence or absence of the indicators of diagnosis excessive fluid volume. In the second step, the spreadsheets were sent to three nurses diagnosticians, who judged the presence or absence of diagnosis in the clientele searched. This step was conducted from july to september 2013. For analysis of the data, we used descriptive and inferential statistics. In the descriptive analysis, we used measures of central tendency and dispersion. In inferential analysis, we used the tests Chi- square, Fisher and prevalence ratios. The accuracy of the clinical indicators pertaining to the diagnosis were measured as to the specificity, sensitivity, predictive values, likelihood ratios and Diagnostic Odds Ratio. Also developed a logistic regression. The results were organized in tables and discussed with literature. This study was approved by the Ethics Committee in Research of the Federal University of Rio Grande do Norte, with Presentation Certificate for Ethics Appreciation nº 08696212.7.0000.5537. The results revealed that the diagnosis studied was present in 82% of patients. The characteristics with prevalence above 50 % that stood out were: azotemia, decreased hematocrit, electrolyte imbalance, intake exceeds output, anxiety, edema, decreased hemoglobin, oliguria and blood pressure changes. Eight defining characteristics were presented statistically significant association with the nursing diagnosis investigated: pulmonary congestion, intake exceeds output, electrolytes imbalance, jugular vein distension, edema, weight gain over short period of time, agitation and adventitious breath sounds. Among these, the 10 characteristics which showed higher prevalence ratios were: edema and weight gain over short period of time. The features with the highest sensitivity were edema, electrolytes imbalance and intake exceeds output and the standing out with greater specificity were: anasarca, weight gain over short period of time, change in respiratory pattern, adventitious breath sounds, pulmonary congestion, agitation and jugular vein distension. The indicators jugular vein distension, electrolytes imbalance, intake exceeds output, increased central venous pressure and edema, together, were identified in the logistic regression model as the most significant predictors. It is concluded that the identification of accurate clinical indicators allow a good prediction of the nursing diagnosis of excessive fluid volume in patients undergoing hemodialysis in order to assist the nurse in the inference process, which will contribute to the success of patient care. In addition, nurses will consider for diagnostic inference not only his clinical experience, but also scientific evidence of the occurrence of excessive fluid volume, contributing to the control of volemia in these patients

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To dev elop and evaluate the use of a body adjustable device for training of peripheral venous catheterization for healthcare undergraduate students . METHODS: This study involved two phases: I) development of the innovative simulator and II) a controlled trial co mparing the performance of the body adjustable device in relation to the commercial simulator for the training of venipuncture skills. A total of 79 first - year medical students participated in the intervention phase, which consisted of pretest assessment, lecture on peripheral venous access, randomization into two groups according to the simulator used for training (Commercial Simulator and Experimental Simulator), real venipuncture procedure, post - test assessment and evaluation of satisfaction. RESULTS: Gr oups were homogeneous in age, sex, pre - test and post - test scores, attitudinal assessment and performance in performing the real venipuncture. Students from the Experimental Simulator group performed better on the filling of simulated records. At the end of the study, cognitive gain significantly increased in both groups. The degree of realism perceived by students was equivalent for two groups. A total of 85.7% of students rated the Experimental Simulator as good or excellent. CONCLUSIONS: Experimental simu lator proved to be a low cost alternative for the training of venipuncture skills in upper limb. The cognitive procedural and attitudinal performances of students who used the experimental simulator were similar to those observed in the group trained with commercial simulator.