11 resultados para athletic performance, hot climate, plethysmography, hydrotherapy, recovery.
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Space Science was built using a composite made of plaster, EPS, shredded tires, cement and water. Studies were conducted to thermal and mechanical resistance. Inside the mold EPS plates were placed in order to obtain a higher thermal resistance on the wall constructed, as well as to give it an end environmentally friendly in view of both the tire and the EPS occupy a large space in landfills and year need to be degraded when released into the environment. Compression tests were performed according to ABNT blocks to seal, measurements of the temperature variation in the external and internal walls using a laser thermometer and check the temperature of the indoor environment using a thermocouple attached to a digital thermometer. The experiments demonstrated the heat provided by the composite values from the temperature difference between the internal and external surfaces on the walls, reaching levels of 12.4 ° C and room temperature in the interior space of the Science of 33.3 ° C, remaining within the zone thermal comfort for hot climate countries. It was also demonstrated the proper mechanical strength of such a composite for sealing walls. The proposed use of the composite can contribute to reducing the extreme housing shortage in our country, producing popular homes at low cost and with little time to work
Resumo:
The kinanthropometric characteristics are used by the sports science as selection criteria and detection of talents. Hence, this study aimed at comparing the anthropometrical profile, the body composition, the somatotype and the vertical jumps of the beach volleyball players. This study consists of 79 male beach volleyball players, being forty nine (n=49) Brazilian participants of the National Circuit and thirty (n=30) of 15 countries participating in the XV Pan American Games. In order to analyze the vertical jumps of the Brazilian the participants were allocated into two groups (G1 and G2) in agreement with the national ranking of their teams. The vertical jump protocol developed by Smith and collaborators was used to evaluate the vertical jumps of spike and block. The Heath-Carter anthropometrical technique (1990) was used for calculating the somatotype. The Student s t test with the Bonferroni adjustment was used to calculate the differences among the investigated variables. The multiple regression analysis was used to identify the contributions of the anthropometrical variables in the performance of the vertical jumps and the multivariance analysis was used to calculate the differences among the components of the somatotype. The Brazilian athletes of G1 were better than G2 in the spike jump (p <0.01), block jump (p <0.01) and in the block difference (p <0.01). The prediction model of the spike jump of G2 included the body mass and standing spike reach (adjusted R2 = 0.77), the body mass and the standing block reach were also included in the model of the block jump (adjusted R2 = 0.73). The regression model of G1 was not statistically significant. As for the somatotype, statistically significant differences were found between the Brazilians and the Pan Americans (Wilks' lambda = 0.498; p <0.05). The Brazilian somatotype was classified as balanced mesomorph (2.7-4.3-3.0) and the Pan American somatotype as endomorphic mesomorph (3.5-4.6-2.4). As to the specific position of the block game (2.8-4.3-2.9) and the defense game (2.6-4.4-3.0), the Brazilian somatotype was classified as balanced mesomorph and the Pan American somatotype, the block (3.7-4.4-2.4) and the defense (3.4-4.9-2.3), was classified as endomorphic mesomorph. In conclusion, the vertical jump height (spike and block) influences the male Brazilian beach volleyball players performance. The physical type of the Brazilian blockers and defenders was similar with relationship to the somatotype. The Brazilian and Pan American beach volleyball players differ in terms of kinanthropometric characteristics. This work had a multidisciplinary feature with the participation of several departments and laboratories, like the Physiotherapy Department, the Nutrition Department, the Physical Education Laboratory, thus corroborating the multidisciplinary research feature
Resumo:
Objective: The aim of the study was to investigate physical characteristics and to examine association between somatotype and performance in collegiate runners of 100 m and 400 m. Methods: The sample, male runners (n=39) competing at the regional level in the state of Rio Grande do Norte, Brazil, had height, body mass, skinfolds, limb circumference and skeletal breadths measured. Then, the somatotype was calculated by Health-Carter method. Races (100 m and 400 m) were held to assess athletic performance. Descriptive statistics were calculated for the total sample, as well as for the 100 m and 400 m groups, and established four subgroups, named quartiles. For analysis between groups of runners (100 m x 400 m) was used Student's t test for independent samples. To examine the relationship between the race times and anthropometric variables, was used the Pearson correlation test. The somatotype dispersion distance and somatotype spatial distance were calculated among subgroups. One-way analysis of variance, the Wilcoxon test followed of Tukey post test, and correlation analysis were used with a significance level of p<0.05. Results: Somatotype with mesomorphy and ectomorphy dominance was exhibited by 100 m and 400 m athletes. Endomorphy was low in both groups, especially in 400m runners, who had more elongated body types than 100 m runners. When separately compared by athletic performance quartile, 100 m sprinters of better qualifications (G100-G1) had somatotype with dominant mesomorphy, whereas 400 m runners had somatotype with dominant ectomorphy. A significant correlation (r = -0.55, p=0.008) between calf circumference and 100 m race times was observed showing the importance of muscularity, whereas a significant correlation was found between height and 400 m race times (r = -0.53, p=0.02) showing the importance of linearity. Conclusion: Runners of 100 and 400 may show differences in physical characteristics, depending on the level of athletic performance. Anthropometric periodic evaluations may help in the training process of these athletes. However, more specific assessment parameters should be taken into account, because somatotype by itself has not power to predict whether an individual will succeed in racing speed
Resumo:
Waste stabilization ponds (WSP) have been widely used for sewage treatment in hot climate regions because they are economic and environmentally sustainable. In the present study a WSP complex comprising a primary facultative pond (PFP) followed by two maturation ponds (MP-1 and MP-2) was studied, in the city of Natal-RN. The main objective was to study the bio-degradability of organic matter through the determination of the kinetic constant k throughout the system. The work was carried out in two phases. In the first, the variability in BOD, COD and TOC concentrations and an analysis of the relations between these parameters, in the influent raw sewage, pond effluents and in specific areas inside the ponds was studied. In the second stage, the decay rate for organic matter (k) was determined throughout the system based on BOD tests on the influent sewage, pond effluents and water column samples taken from fixed locations within the ponds, using the mathematical methods of Least Squares and the Thomas equation. Subsequently k was estimated as a function of a hydrodynamic model determined from the dispersion number (d), using empirical methods and a Partial Hydrodynamic Evaluation (PHE), obtained from tracer studies in a section of the primary facultative pond corresponding to 10% of its total length. The concentrations of biodegradable organic matter, measured as BOD and COD, gradually reduced through the series of ponds, giving overall removal efficiencies of 71.95% for BOD and of 52.45% for COD. Determining the values for k, in the influent and effluent samples of the ponds using the mathematical method of Least Squares, gave the following values respectively: primary facultative pond (0,23 day-1 and 0,09 day-1), maturation 1 (0,04 day-1 and 0,03 day-1) and maturation 2 (0,03 day-1 and 0,08 day-1). When using the Thomas method, the values of k in the influents and effluents of the ponds were: primary facultative pond (0,17 day-1 and 0,07 day-1), maturation 1 (0,02 day-1 and 0,01 day-1) and maturation 2 (0,01 day-1 and 0,02 day-1). From the Partial Hydrodynamic Evaluation, in the first section of the facultative pond corresponding to 10% of its total length, it can be concluded from the dispersion number obtained of d = 0.04, that the hydraulic regime is one of dispersed flow with a kinetic constant value of 0.20 day-1
Resumo:
On the evening of April 1, 1981, the city of Santa Cruz was taken by a flood that destroyed the spillway weir Santa Cruz and much of the city, causing the population of the lower areas to abandon their homes. Residences and closest to the dam, the river and the creek Trairi Sin streets were totally affected, and many of the houses and public buildings completely destroyed. Located in the state of Rio Grande do Norte, the city of Santa Cruz is marked by a very hot climate and semi-arid. With an average normal rainfall of 498.7 mm per year, the city is affected by drought since the beginning of its foundation, around the year 1831. For its development had continued, it was necessary that the population actualize various environmental interventions Nature, especially as regards the storage and distribution of water. Considering the process of occupying the space in question, as well as the relationships that human groups have with the natural environment, we aim to analyze how human interventions affect the environment around them, modifying it to meet their needs and interests. Thus, we intend to understand how media coverage enabled the construction of a framework of tragedy. We intend to observe how the occupation of Santa Cruz led to the modification of their surroundings, trying to discuss the effects of human intervention on natural disasters. Among the research sources include newspapers A República, Diário de Natal, Tribuna do Norte, O Poti and Folha de São Paulo, as well as interviews with the then mayor of Santa Cruz, Hildebrando Teixeira de Souza, and with the couple José Henrique de Pontes and Severina Aguida de Pontes, whose house was hit by the flood. We will also take messages from the state government, the minutes of the city council of Santa Cruz and reports produced by DNOCS on the construction of the weir and its survey after the flood.
Resumo:
The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential
Resumo:
The goal of the research was to investigate the energy performance of residential vertical buildings envelope in the hot and humid climate of Natal, capital of Rio Grande do Norte, based in the Technical Regulation of Quality for Energy Efficiency Level in Residential Buildings (RTQ -R), launched in 2010. The study pretends to contribute to the development of design strategies appropriate to the specific local climate and the increasing of energy efficiency level of the envelope. The methodological procedures included the survey in 22 (twenty two) residential buildings, the formulation of representative prototypes based on typological and constructives characters researched and the classification of the level of energy efficiency in the envelopment of these prototypes, using as a tool the prescriptive method of the RTQ-R and the parametric analyzes from assigning different values of the following variables: shape of the pavement type; distribution of housing compartments; orientation of the building; area and shading of openings; thermal transmittance, and solar absorptance of opaque materials of the frontage in order to evaluate the influence of these on the envelopment performance. The main results accomplished with this work includes the qualification of vertical residential buildings in Natal/RN; the verification of the adequacy of these buildings to local climate based from the diagnosis of the thermal energy of the envelopment performance, the identification of variables with more significant influence on the prescriptive methodology of RTQ-R and design solutions more favorable to obtain higher levels energy efficiency by this method. Finally, it was verified, that some of these solutions proved contradictory in relation to the recommendations contained in the theoretical approaches regarding environmental comfort in hot and humid weather, which indicates the need for improvement of the prescriptive method RTQ-R and further research on efficient design solutions
Resumo:
Objectives: To evaluate how to develop dynamic hyperinflation (DH) during exercise, the influence of pursed-lip breathing in (PLB) on breathing pattern and operating volume in patients with asthma. Methods: We studied 12 asthmatic patients in three moments: (1) anthropometry and spirometry, (2) submaximal incremental cycle ergometer test in spontaneous breathing and (3), submaximal incremental test on a cycle ergometer with PLB using the Opto-electronic plethysmography. Results: Evaluating the end-expiratory lung volume (EEV) during submaximal incremental test in spontaneous breathing, patients were divided into euvolume and hyperinflated. The RFL has increased significantly, the variation of the EEV group euvolume (1.4L) and decreased in group hyperinflated (0.272L). In group volume observed a significant increase of 140% in Vt at baseline, before exercise, comparing the RFL and spontaneous breathing. Hyperinflated group was observed that the RFL induced significant increases of Vt at all times of the test incremental baseline, 50%, 100% load and 66% recovery, 250%, 61.5% and 66% respectively. Respiratory rate decreased significantly with PLB at all times of the submaximal incremental test in the group euvolume. The speed of shortening of inspiratory muscles (VtRcp/Ti) in the hyperinflated increased from 1.6 ± 0.8L/s vs. 2.55 ± 0.9L/s, whereas in the RFL euvolume group ranged from 0.72 ± 0.31L/s vs. 0.65 ± 0.2L/s. The velocity of shortening of the expiratory muscles (VtAb/Te) showed similarity in response to RFL. In group hyperinflated varied vs. 0.89 ± 0.47 vs. 0.80 ± 0.36 and ± 1.17 ± 1L vs. 0.78 ± 0.6 for group euvolume. Conclusion: Different behavior in relation to EEV in patients with moderate asthma were observed, the HD and decreased EEV in response to exercise. The breathing pattern was modulated by both RFL performance as at home, making it more efficient
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher