4 resultados para Windows Mobile 5.0

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthetic guanylhydrazones WE010 (3,5-di-tert-butil-4-hidroxibenzaldehyde-guanylhydrazone), WE014 (4-bifenilcarboxialdehydeguanylhydrazone) and WE017 (3,4-diclorobenzaldehydeguanylhydrazone) showed high cytotoxic activity in terms of percentage inhibition of cancer cells growth. However, further progress in the development of these drug candidates requires precise and convenient methods for their qualitative and quantitative analyses. The aim of this study was to develop and validate High Performance Liquid Chromatography with diode-array detection (HPLC-DAD) and Ultra Fast Liquid Chromatography with diode-array detection (UFLC-DAD) methods suitable for as simultaneous as isolated determination of studied guanylhydrazones, based on the optimization of chromatographic parameters and obtaining reduced detection times. The chromatographic analyses of analytes by HPLC were performed on C18 ACE analytical column (150 mm x 4.6 mm), with a particle size of 5.0 μm. Among all the conditions assayed, the best results of separation were obtained with a mixture of methanol:water (60:40, v/v) as the mobile phase at a flow rate 1.5mL/min and pH of 3.5 adjusted at acetic acid. The UFLC method was developed by experimetal desing techniques in order to find optimal chromatographic analytical conditions, which were achieved on XR-ODS analytical column (50 mm x 3.0 mm), with a particle size of 2,2 μm, maintained at 25 ºC. The mobile phase was consisted of methanol:water (65:35, v/v) with 0.1% triethylamine (TEA) and pH of 3.5 adjusted at acetic acid, at a flow rate 0.5 mL/min. The procedure were validated following evaluating parameters such as specificity, linearity, limits of detection (LD) and quantification (LQ), precision, accuracy and robustness, giving results within the acceptable range. Although the UFLC method shows better sensitivity (lower values of LD and LQ), robustness (lower rates of relative standard deviation) and minimize spending time and solvent, both developed methods were adequately applied to the analysis of guanylhydrazones molecules, may be used in routine of quality control laboratories. Keywords: guanylhydrazones, HPLC/DAD, UFLC/DAD, validation of analitical method

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To characterize patients according to gender, age category, internment time, diagnostical hypothesis and location of the pressure ulcer; to identify the susceptibility conditions, intrinsical and extrinsical factors present on ICU patients and to verify on the existence of association between the susceptibility conditions and the intrinsecal and extrinsecal factors on the occurrence of PU. Methods: It is a descriptive study, of longitudinal design of the panel type, with quantitative approach, performed on two ICU s of a private hospital located in Natal/RN, with 40 patients interned at these units. The data collection was performed on all three shifts through a structured observation and physical exam of the patients' skin form seeking to identify the presence of PU. Results: The greatest occurence of PU was on individuals of the male gender (70%) when compared to the female gender (30%), that difference being statistically significant (p=0,0267), with the male gender presenting 4,3 times greater chance of developing PU than the female; the predominant age category was from 60 years of age on (85%), 60,0% presented 1 to 2 PU s after 7 (seven) days of permanence in the ICU s, the predominant diagnostical hypothesis on the patients with PU were the respiratory diseases (42,3%) and the most frequent locations of PU were the sacral region (40,0%) and heels (36,0%). 25 PU s of stage I were diagnosed on 50,0% of the followed patients, with general incidence of 50,0% on both ICUs. from the 88 variables researched, 75 were identified on the patients from the study, being the predominant conditions (anemia, hypotension, leukocytosis, other diseases hypertension blood pressure, cardiac insuffience, pneumonia - and ansiolythic), the intrinsecal factors (diminished muscular strenght and/or mass, discrete edema, totally compromised mobile coordination and total inability for movement on the bed) and the extrinsecal factors (inadequate mattress type, permanence on a single position for >2 hours, shearing/friction force, bed clothes with folds that leave marks on the body, pressure force) predominated on patients with PU. The male gender variables (p=0,0267,OR=4,3), sedation (p=0,0006,OR=4,1), psychomotive agitation (p=0,0375,OR=5,8) and leukocytosis (p=0,0285,OR=5,0) presented a significant statistical diference when analyzed independently. We verified an association of 17,3%, statistically significant (p=0,0384), between the susceptibility conditions (anemia, leukocytosis and hypotension), the intrinsecal factors (age equal or above 60 years, diminished/absent pain sensibility and smooth, fine or delicate skin) and the extrinsecal factors (inadequate mattress, pressure forces, shearing/friction force, permanence on a single position for more than 2 hours, elevation between 30 to 45 degrees and inadequate bed clothes' conditions), with a chance ratio of 4,6 times the risk of occurrence of PU on the patients that presented the referred association. Conclusion: The incidence of PU detected on the ICU-interned patients was high and we made evident the existence of association between the susceptibility conditions, the intrinsecal and extrinsecal factors on the occurrence of PU s on the ICUinterned patients, and thus we accept the alternative hypothesis proposed on the study

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to investigate the factors that inhibit the use of Environmental Techniques in the Gas Station of the city of Natal/RN. For this, a survey with the aid of a questionnaire was used like research instrument. It s used a sample for convenience, not probabilistic. For collection of the data, it was used directly application of the questionnaire to the Managers or Assistant managers of the gas station, in accordance with its availability or presence. The data was collected in all the regions of Natal (North, South, East and West). The population in accordance with the data of the ANP of September 2005 is of 111 ranks and the collected sample was of 86. To carry through the analysis of the data of this research had been used softwares Excel and Statistic version 5.0, for Windows. The analysis of data is divided in two parts; descriptive analysis and analysis of groupings (clusters). The results showed that bigger part of the interviewed ones has between 30 and 39 years of age; they have second grade completed; they had declared to have little between and reasonable knowledge how much to the use of Clean Technology (CT) in gas station; and a small part of the interviewed ones had informed to have much knowledge how much the resolutions of the CONAMA established for the Gas Station. Of the searched ranks, the majority is national(76.7%); the most accurate practice environmental used in the gas station are: it collects selective of oil used or contaminated and ecological tanks - coated with strengthened fibre glass; great part of the interviewed ones (33.8%) informed that never the TL makes planning of referring future action; about of the half of the interviewed ones (84.9%) they had more declared that its employees have of none to a reasonable level of training for deal with problems that compromise the environment; the majority of the ranks (72.1%) functions has for more then six years. It is observed that almost all the interviewed ones (96.5%) evaluate as being important or very important the implantation of CT in Gas Station and the great majority (82.1%) evaluates the difficulty in if implanting these technologies in Gas Station as being easy or very easy. In the analysis of cluster, it was verified existence of two groupings (as much in the variable of the barriers and benefits), being that inside of each clusters exists homogeneity and between clusters exists heterogeneity. In reality, everything is important or very important in the opinion of the interviewed ones. There only exists a small significant difference that separates them in clusters

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Obesity impairment to the pulmonary function related to the magnitude of adiposity and is associated with excessive daytime sleepiness (EDS) and snoring, among others symptoms of respiratory disorders related to sleep. It is possible that obese individuals with excessive daytime sleepiness may make changes in lung function on spirometry monitored during the day as a consequence of fragmented sleep or episodes of nocturnal hypoventilation that cause respiratory and changes that can persist throughout the day. The combination of these findings alone sleepiness observed by subjective scales with pulmonary function in obese patients is unknown. Objective: To assess the influence of EDS and snoring on pulmonary function in morbidly obese and distinguish between different anthropometric markers, the snoring and sleepiness which the best predictors of spirometric function and respiratory muscle strength and endurance of these patients. Methods: We evaluated 40 morbidly obese markers on the anthropometric, spirometric respiratory variables, maximal inspiratory and expiratory pressures (MIP and MEP) and maximal voluntary ventilation (MVV) and the measured excessive daytime sleepiness (the Epworth sleepiness scale) and snoring (snoring scale of Stanford). The data were treated when the differences between the groups of obese patients with and without sleepiness, whereas the anthropometric variables, respiratory and snoring. Pearson's correlation was performed, and multiple regression analysis assessed the predictors of pulmonary function. For this we used the software SPSS 15.0 for windows and p <0.05. Results: 39 obese patients were included (28 women), age 36.92+11.97y, body mass index (BMI) 49.3+5.1kg/m², waist-hip ratio (WHR) 0.96+0.07 and neck circumference (NC) 44.1+4.2 cm. Spirometric values and respiratory pressures were up 80% of predicted values, except for endurance (MVV <80%). Obese with EDS have lower tidal volume. Positive correlation was observed between BMI and EDS, EDS and NC and between snoring and BMI, and negative correlation between EDS and tidal volume (TV), and between snoring and snoring FVC and FEV1. In linear regression the best predictor of pulmonary function was snoring, followed by NC. NC has more obese with higher strength (MEP, p = 0.031) and endurance (MVV p = 0.018) respiratory muscle. Conclusion: Obese with EDS tend to have lower TV. In addition, snoring and NC can better predict pulmonary function in obese when compared with other anthropometric markers or EDS. Obese patients with higher NC tend to have greater capacity for overall strength of respiratory muscles, but may have low muscle endurance