14 resultados para Wind speed extrapolation

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work analyses a study on natural ventilation and its relation to the urban legislation versus the building types in an urban fraction of coastal area of Praia do Meio in the city of Natal/RN, approaching the type or types of land use most appropriate to this limited urban fraction. The objective of this study is to analyse the effects of the present legislation as well as the types of buildings in this area on the natural ventilation. This urban fraction was selected because it is one of the sites from where the wind flows into the city of Natal. This research is based on the hypothesis stating that the reduction on the porosity of the urban soil (decrease in the set back/boundary clearance), and an increase in the form (height of the buildings) rise the level of the ventilation gradient, consequently causing a reduction on the wind speed at the lowest part of the buildings. Three-dimensional computational models were used to produce the modes of occupation allowed in the urban fraction within the area under study. A Computational Fluid Dynamics (CFD) software was also used to analyse the modes of land occupation. Following simulation, a statistical assessment was carried out for validation of the hypothesis. It was concluded that the reduction in the soil porosity as a consequence of the rates that defined the minimum boundary clearance between the building and the boundary of the plot (and consequently the set back), as well as the increase in the building form (height of the buildings) caused a reduction in the wind speed, thus creating heat islands

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work studies the natural ventilation and its relationship with the urban standards, which establishes the form of occupation and use of the land in our cities. The method simulates the application of the urban standards of the City Master Plan over the last three years. The simulation takes place in the District of Petrópolis, in the city of Natal , Brazil and analyses the effects of the standards of natural ventilation. The formulated hypothesis states that the reductions in the urban spaces between buildings rises up the vertical profile of ventilation, reducing, therefore, the velocity of the wind at the lower levels of the buildings. To develop the study, occupation models were built, using computerized, three-dimensional models. These occupation models were analyzed using the CFD (Computational Fluid Dynamics) code. The conclusion is that the more we reduce the urban space between buildings, the more we reduce the wind speed in constructed areas, increasing, therefore, the possibility to generate heat islands

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Caatinga is the predominant vegetation type in semi-arid region of Brazil, where many inhabitants depend on hunting and gathering for survival, obtaining resources for: food and feed, folk medicine, timber production, etc. It‟s the dry ecosystem with highest population density in the world. The early stages of development are the most critical during the life cycle of a flowering plant and they‟re primordial to its establishment in environments exposed to water stress. Information about adjustments to the growth of the species, correlated with their studies of distribution in Seridó oriental potiguar, are an important ecological and economic standpoint, because they provide subsidies for the development of cultivation techniques, to programs of sustainable use and recovery of degraded areas. This thesis aimed to study the initial growth and foliar morphology in plants like Enterolobium contortisiliquum (Vell.) Morong. (tamboril) and Erythrina velutina Mart. ex Benth (mulungu), species of occurrence in the Caatinga, under water stress. After sowing and emergency, the seedlings were exposed to three water regimes: 450 (control), 225 (moderate stress) and 112.5 (severe stress) mm of water slide for 40 days. Seeding occurred in bags of 5 kg and after the establishment of seedlings thinning was carried out leaving a plantlet per bag. At the beginning the waterings occurred daily with distilled water, passing to be on alternate days after thinning. Twenty and forty days after the thinning seedlings collections were held to be done analysis of growth and biomass partition. When compared to the control group, the treatments with water stress showed reduction in the growth of the aerial part, growth of the greater root, number of leaves and leaflets, dry leaf area and total phytomass in both species, but in general, this effect was most marked for E. velutina. Regarding the partition of biomass, there were few changes throughout the experiment. Morphological changes in the leaves as a function of stress were not significant, however, there was a trend, in both species, to produce narrower leaves, that facilitate heat loss to the environment. It has not been possible to establish a positive relationship between inhibition of growth and distribution of species, whereas E. velutina is a species of most common occurrence in Seridó oriental potiguar. In this way, other aspects should be taken into account when studying the adaptation of species the dry environments, such as salinity, presence of heavy metals, wind speed, etc

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to use a computational model that considers the statistical characteristics of the wind and the reliability characteristics of a wind turbine, such as failure rates and repair, representing the wind farm by a Markov process to determine the estimated annual energy generated, and compare it with a real case. This model can also be used in reliability studies, and provides some performance indicators that will help in analyzing the feasibility of setting up a wind farm, once the power curve is known and the availability of wind speed measurements. To validate this model, simulations were done using the database of the wind farm of Macau PETROBRAS. The results were very close to the real, thereby confirming that the model successfully reproduced the behavior of all components involved. Finally, a comparison was made of the results presented by this model, with the result of estimated annual energy considering the modeling of the distribution wind by a statistical distribution of Weibull

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work purposes the application of a methodology to optimize the implantation cost of an wind-solar hybrid system for oil pumping. The developed model is estimated the implantation cost of system through Multiple Linear Regression technique, on the basis of the previous knowledge of variables: necessary capacity of storage, total daily energy demand, wind power, module power and module number. These variables are gotten by means of sizing. The considered model not only can be applied to the oil pumping, but also for any other purposes of electric energy generation for conversion of solar, wind or solar-wind energy, that demand short powers. Parametric statistical T-student tests had been used to detect the significant difference in the average of total cost to being considered the diameter of the wind, F by Snedecor in the variance analysis to test if the coefficients of the considered model are significantly different of zero and test not-parametric statistical by Friedman, toverify if there is difference in the system cost, by being considered the photovoltaic module powers. In decision of hypothesis tests was considered a 5%-significant level. The configurations module powers showed significant differences in total cost of investment by considering an electrical motor of 3 HP. The configurations module powers showed significant differences in total cost of investment by considering an electrical motor of 5 HP only to wind speed of 4m/s and 6 m/s in wind of 3 m, 4m and 5 m of diameter. There was not significant difference in costs to diameters of winds of 3 m and 4m. The mathematical model and the computational program may be used to others applications which require electrical between 2.250 W and 3.750 W. A computational program was developed to assist the study of several configurations that optimizes the implantation cost of an wind-solar system through considered mathematical model

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We built an experimental house on an UFRN´s land using blocks made by a composite consisting of cement, plaster, EPS, crushed rubber and sand. Several blocks were made from various compositions and we made preliminary tests of mechanical and thermal resistance, choosing the most appropriate proportion. PET bottles were used inside the block to provide thermal resistance. In this work, a second function was given to the bottles: to serve as a docking between the blocks, because the ends of the cylinders came out of each block on top as well as at the bottom, with the bottom cut, allowing to fit of the extremities of the upper cylinder of a block in the lower holes of the other one, which were formed by the cutting already mentioned. Minimum compression tests were performed according to ABNT standards for walls closing blocks (fence). With that house built, we did studies of thermal performance in order to ascertain conditions of comfort, checking external and internal temperatures in the walls and in the ambient, among other variables, such as wind speed and relative humidity. The resulting blocks provided adequate thermal insulation to the environment, where the walls presented differences up to 11.7 ºC between the outer and inner faces, getting the maximum temperature inside the house around 31 °C, within the so-called thermal comfort zone for warm climates. At the end of the experiments it was evident the effectiveness of that construction in order to provide thermal comfort in the internal environment of the house, as well as we could confirm the viability of building houses from recyclable materials, reducing the constructive costs, becoming a suitable alternative for low- incoming families. Moreover, besides the low cost, the proposal represents an alternative use of various recyclable materials, therefore considered an ecological solution

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We developed an assay methodology that considered the temperature variation and the scanning electron microscopy as a method to quantify and characterize respectively the consumption evolution in three 46 LA machines, with internal combustion and two-stroke engines, 7.64 cm3 cylinder capacity, 23.0 millimeters diameter and 18.4 millimeters course, RPM service from 2.000 to 16.000 rpm, 1.2 HP power, and 272 grams weight. The investigated engines components were: (1) head of the engine (Al-Si alloy), (2) piston (Al-Si alloy) and (3) piston pin (AISI 52100 steel). The assays were carried out on a desktop; engines 1 and 2 were assayed with no load, whereas in two assays of engine 3 we added a fan with wind speed that varied from 8.10 m/s to 11.92 m/s, in order to identify and compare the engine dynamic behavior as related to the engines assayed with no load. The temperatures of the engine s surface and surroundings were measured by two type K thermopairs connected to the assay device and registered in a microcomputer with data recording and parameters control and monitoring software, throughout the assays. The consumed surface of the components was analyzed by scanning electron microscopy (SEM) and microanalysis-EDS. The study was complemented with shape deformation and mass measurement assays. The temperature variation was associated with the oxides morphology and the consumption mechanisms were discussed based on the relation between the thermal mechanical effects and the responses of the materials characterization

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work study of solar distillation feasibility in effluent of petroleum industry: produced water, making possible your reuse for irrigation of oleaginous cultures or fodder crops or in steam generation, as well the transport phenomena involved. The methodology for development of this project was to characterize the effluent to be treated and to accomplish physical and chemical analysis in the distilled, to build distillation equipment, concomitant operation of both equipments and implementation of data processing and economical evaluation. The methodology used for all parameters is outlined in APHA (1998) and sampling of the type compound. The feeding of distillation equipment was performed with treated effluent from UTPF of Guamaré. The temperature was monitored throughout the distillers and during the time of operation. The distillers feed occur, as a rule, for sifon. The distillers were operated by a period of 17 months between July 2007 and February 2009, in which 40 experiments were performed. The radiation and temperature datas were acquired in the INPE s site and the temperature inside of the distillers was registered by DATALOGGER Novus. The rates of condensation (mL / min) were determined by measuring of the flow in a graduate test tube of 10 mL and a chronometer. We used two simple solar effect distillers of passive type with different angles in coverage: 20 ° and 45 °. The results obtained in this study and the relevant discussions are divided into six topics: sample characterization and quality of distilled; construction of distillers; operation (data, temperature profile), climatic aspects, treatment of data and economical analysis. Results obtained can be inferred that: the energy loss by the adoption of vessel glass was not significant, however, complicates the logistics of maintenance the equipment on a large scale. In the other hand, the surface of the tub with a glass shield on the equipment deterioration, both devices showed similar performance, so there is not justified for use of equipment 450. With regard to the climatological study it was verified that the Natal city presents monthly medium radiation varying in a range between 350 and 600 W/m2, and medium of wind speed of 5 m / s. The medium humidity is around 70% and rainfall is very small. The regime of the system is transient and although it has been treated as a stationary system shows that the model accurately represents the distillers system's 20 degrees. The quality of the distilled with regard to the parameters evaluated in this study is consistent with the Class 3 waters of CONAMA (Resolution 357). Therefore we can conclude that solar distillation has viability for treat oilfield produced water when considered the technical and environmental aspects, although it is not economically viable

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bats correspond to 20% of the extant mammal species and, with a few exceptions, use echolocation, a spacial orientation system based on emission and analysis of echoes from sound waves, generally ultrasounds. Echolocation was discovered in the 1940 s and since the 1970 s ultrasound detectors have been commercially available, allowing the investigation of several aspects of the natural history and ecology of bats. Passive acoustic monitoring has been frequently used in habitat use studies, predominantly in North America and Europe, by comparing the number of bat passes between different habitat types. This dissertation presents the first evaluation of the spacial and seasonal variation patterns in the activity of insectivorous bats in the Brazilian biome Pampa, in the state of Rio Grande do Sul. Since bat activity can vary according to habitat type, time of year and climatic conditions, the following hypotheses were tested: 1. bat activity varies between different types of habitat; 2. bat activity varies seasonally; 3. bat activity is influenced by temperature, humidity and wind speed. The acoustic samples were taken along fixed transects of 1500 meters, which were monitored monthly from April 2009 to March 2010. Five habitat types were sampled: eucalypts, stream, riparian forest, wetland and grassland. In each sample, the number of bat passes was obtained by using an ultrasound detector Pettersson D230. A total of 1183 bat passes were registered. Greater bat activity levels was observed along large eucalypts (1.93 bat passes/3min) and along a stream (1.61 bat passes/3 min). A riparian forest (0.94 bat passes/3 min) and a wetland area (0.61 bat passes/3 min) exhibited statistically equal levels of activity. Bat passes were fewer in grassland areas (0,16 bat passes/3 min). Bat activity was not correlated with abiotic factors. However, bat activity was significantly low in the colder season, winter, and was similar in autumn, spring and summer. The observed preference for vegetation borders and water courses agrees with reports from other countries and is attributed predominantly to the high prey abundance in these types of environments. Additionally, low activity in the winter is probably a response to the reduced availability of insects, and to lower temperatures. Our results indicate which areas of arboreal vegetation and water courses should be priorities for the conservation of bats and that alterations of these habitat types might negatively influence bat activity in the region

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study presents the Environmental Sensibility Mapping to oil spillings on the Potengi estuary - RN and neighboring coastline through remote sensing data, collecting, treatment and integration of the geomorphologic, oceanographic (temperature, salinity, density, direction and intensity), meteorological (wind speed and direction) and high resolution seismic (bathymetry and sonography) data. The Potengi river estuary is located on the eastern coastline of the Rio Grande do Norte State, being inserted in the geological context for the coastal Pernambuco-Paraíba basin and spreading over 18 km; it shelters the Natal harbor zone and an oil terminal, centralizing, therefore, important oil transport operations that can cause accidental spillings. Under the oceanographic point of view, the Potengi estuary is characterized by the absence of any expressive thermic stratification, being classified as partially mixed, B type according to Pritchard (1955), and 2 type in conformity to the stratification-circulation diagram by Hansen & Rattray (1966). Two main wind systems are responsable for the formation of wave sets that occur in the area. The dynamic tide presents, in the Natal Harbor, mean amplitude in spring and quadrature tides, with around 2.8 and 2m, respectively. The mechanism of saline tide mixing was defined through the salinity which is the main parameter for the identification of this mechanism. Important variations of the salinity mean values (36.32 psu), temperature (28.11ºC) and density (22.96 kg/m3) in the estuarine waters presented features belonging to low latitude regions. The water temperature follows the air temperature variations, in the region, with expressive daily amplitudes. In this study, the identification of the estuarine bed morphology through bathymetric and sonographic analysis, had the purpose to evaluate the influence of the superficial and bottom currents for the bottom shaping. In this way, the use of the side scan sonar showed, to be very useful in the identification of the bottom morphology and its relationship with the predominant action of the tidal currents in the Potengi estuary. Besides, it showed how the sonograms can be a support to the comparison of the several patterns derived from the local hydrodynamic variations. The holocene sediments, which fill the estuarine channel, are predominantly sandy, varying from selected, sometimes silty. The sedimentation is controlled by the environmental hydrodynamic conditions, being recognized two important textural facies: Muddy Facies and Sandy Facies. The distribution of these textural facies apparently oscillates owing to the tidal cycle and flow intensity. Each one of the above mentioned data was integrated in a Geographic Information System (GIS), from which was produced the Environmental Sensibility Map to oil spillings with Coastal Sensibility Index (CSI) to the Potengi estuary. The integrated analysis of these data is essential to oil spilling contingency plans, in order to reduce the spilling environmental consequences and to make efficient the endeavours of contention and cleaning up/removal on the Natal Harbor. This study has the aim to collaborate for the increase of informations about the estuarine environment and contribute to a better management of the question: environment/polluting loads

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study analyzed measurements of the aeolian transport using vertical sand traps across the field dunes of Jenipabu, in the municipality of Extremoz, Rio Grande do Norte state to the North of Natal city. These measurements were used as parameters for the sand aeolian transport in the region. Before the field trips a map of landscape units was made. Three visits to the field were done in September 2011 (field a - the 13th, field b - the 21st, field c - the 29th), period of the year with the highest wind speed, and another in December 8th, 2011 (field d ) when the wind speed starts to decrease. The sand traps used were of the type "I" with collecting opening of 25 cm from the surface level, and type "S" with collecting opening of 25 cm located 25 cm from the surface level in six collecting points in two of the visits (fields a and d ), and sand traps of the type "T" with the collecting opening of 50 cm from the surface level in the other field trips (fields "b" and "c"). A set of records was also collected by using a portable meteorological station complemented with information such as frequency and intensity of winds, precipitation and relative air humidity in the region, from the Estação Meteorológica de Natal , located 12 km from the study area. The sediments collected were treated and the data obtained permitted calculating the ratio of sediment transport. In September, the sedimentation ratio varied from 0.01 to 11.39 kg.m-1.h-1 and in December this ratio varied from 0.33 to 1.30 kg.m-1.h-1 in the type T collectors. In type I collectors they ranged from 0.01 to 11.39 kg.m-1.h-1, while the same parameters varied from 0.01 to 0.73 kg.m-1.h-1 in type S collector. Based on the statistical analysis done, we concluded that the sediment transport increased proportionally to the wind speed 25 cm from the surface. However, this is not true above 25 cm from the surface. The transport of sediments is more intense near the surface where sedimentation ratios greater than 10 kg.m-1.h-1 were found, whilst a maximum value of 3 kg.m-1.h-1 was observed 25 cm below the surface. The volume of sediments collected increases with the increasing wind speed at the surface level, whereas this relationship is opposed far away from that surface