41 resultados para Temperatura do ar interior

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this work was the development and improvement of the mathematical models based on mass and heat balances, representing the drying transient process fruit pulp in spouted bed dryer with intermittent feeding. Mass and energy balance for drying, represented by a system of differential equations, were developed in Fortran language and adapted to the condition of intermittent feeding and mass accumulation. Were used the DASSL routine (Differential Algebraic System Solver) for solving the differential equation system and used a heuristic optimization algorithm in parameter estimation, the Particle Swarm algorithm. From the experimental data food drying, the differential models were used to determine the quantity of water and the drying air temperature at the exit of a spouted bed and accumulated mass of powder in the dryer. The models were validated using the experimental data of drying whose operating conditions, air temperature, flow rate and time intermittency, varied within the limits studied. In reviewing the results predicted, it was found that these models represent the experimental data of the kinetics of production and accumulation of powder and humidity and air temperature at the outlet of the dryer

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The State of Paraíba is one of the most dynamic states of Brazil, strategically located in the northeast, is notable for the excellent potential for integration of different transportation modes forming the states of Rio Grande do Norte, Pernambuco and Alagoas. The dynamic that occurs with port activity causes changes in the space where it is installed. And the elements of this space are always more than suffering direct or indirect influences as the flow in the port is expanded. Therefore, this region became subject to the accidental spillage of oil, because it presents a heavy traffic of ships of various sizes that can run aground or collide with oil causing accidental events. The study of geomorphological and sedimentological compositions of seafloor becomes important as more is known about the relationships between these parameters and associated fauna, and can identify their preferred habitats. The database background, acoustically collected along the proposed study area, is a wealth of information, which were duly examined, cataloged and made available. Such information can serve as an important tool, providing a geomorphological survey of the sedimentary area studied, and come to subsidize, in a flexible, future decision making. With the study area Port of Cabedelo, Paraíba - Brazil, this research aimed to evaluate the influence of the tidal surface and background in modeling the seabed, including the acquisition of information about the location of submerged rocky bodies and the depth of these bodies may turn out to be natural traps for the trapping of oil in case of leaks, and obtain the relationship between types of bed and the hydrodynamic conditions present in the region. In this context, for this study were collected bathymetric data (depth) and physical oceanographic (height of water column, water temperature, intensity and direction of currents, waves and turbidity), meteorological (rainfall, air temperature, humidity, winds and barometric pressure) of the access channel to the Port of Cabedelo / PB and its basin evolution (where the cruise ships dock), and includes tools of remote sensing (Landsat 7 ETM +, 2001), so that images and the results are integrated into Geographic Information Systems and used in the elaboration of measures aimed at environmental protection areas under the influence of this scale facilities, serving as a grant to prepare a contingency plan in case of oil spills in the region. The main findings highlight the techniques of using hydroacoustic data acquisition together bathymetric surveys of high and low frequency. From there, five were prepared in bathymetric pattern of Directorate of Hydrography and Navigation - DHN, with the depth in meters, on a scale of 1:2500 (Channel and Basin Evolution of Access to Port of Cabedelo), where there is a large extent possible beachrocks that hinder the movement of vessels in the port area, which can cause collisions, running aground and leaking oil. From the scatter diagram of the vectors of currents, it can be seen as the tidal stream and undergoes a channeling effect caused by the bidirectional effect of the tide (ebb and flood) in the basin of the Port of Cabedelo evolution in NW-direction SE and the highest speed of the currents occurs at low tide. The characterization weather for the period from 28/02 to 04/07/2010 values was within the expected average for the region of study. The multidisciplinary integration of products (digital maps and remote sensing images), proved to be efficient for the characterization of underwater geomorphological study area, reaching the aim to discriminate and enhance submerged structures, previously not visible in the images

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Brazilian Northeast is the most vulnerable region to climatic variability risks. For the Brazilian semi-arid is expected a reduction in the overall rates of precipitation and an increase in the number of dry days. These changes predicted by the IPCC (2007) will intensify the rainfall and droughts period that could promote the dominance of cyanobacteria, thus affecting the water quality of reservoirs, that are most used for water supply, in the semi-arid. The aim of this study was to evaluate the effects of increasing temperature combined with nutrient enrichment on the functional structure of the phytoplankton community of a mesotrophic reservoir in the semi-arid, in the worst case scenario of climate change predicted by the IPCC (2007). Two experiments were performed, one in a rainy season and another in the dry season. In the water sampled, nutrients (nitrate and orthophosphate) were added in different concentrations. The microcosms were submitted to two different temperatures, five-year average of air temperature in the reservoir (control) and 4°C above the control temperature (warming). The results of this study showed that warming and nutrient enrichment benefited mainly the functional groups of cyanobacteria. During the rainy season it was verified the increasing biomass of small functional groups of unicellular and opportunists algae such as F (colonial green algae with mucilage) and X1 (nanoplanktonic algae of eutrophic lake systems). It was also observed an increasing in total biomass, in the richness and diversity of the community. In the dry season experiment there was a greater contribution in the relative biomass of filamentous algae, with a replacement of the group S1 (non-filamentous cyanobacteria with heterocytes) for H1 (filamentous cyanobacteria with heterocytes) in nutrient- enriched treatments. Moreover, there was also loss in total biomass, species richness and diversity of the community. The effects of temperature and nutrients manipulation on phytoplankton community of reservoir Ministro João Alves provoked changes in species richness, the diversity of the community and its functional composition, being the dry period which showed the highest susceptibility to the increase in the contribution of potentially toxic cyanobacteria with heterocytes

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Space Science was built using a composite made of plaster, EPS, shredded tires, cement and water. Studies were conducted to thermal and mechanical resistance. Inside the mold EPS plates were placed in order to obtain a higher thermal resistance on the wall constructed, as well as to give it an end environmentally friendly in view of both the tire and the EPS occupy a large space in landfills and year need to be degraded when released into the environment. Compression tests were performed according to ABNT blocks to seal, measurements of the temperature variation in the external and internal walls using a laser thermometer and check the temperature of the indoor environment using a thermocouple attached to a digital thermometer. The experiments demonstrated the heat provided by the composite values from the temperature difference between the internal and external surfaces on the walls, reaching levels of 12.4 ° C and room temperature in the interior space of the Science of 33.3 ° C, remaining within the zone thermal comfort for hot climate countries. It was also demonstrated the proper mechanical strength of such a composite for sealing walls. The proposed use of the composite can contribute to reducing the extreme housing shortage in our country, producing popular homes at low cost and with little time to work

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work deals with the kinetics assay of Cajá (Spondias mombin L.) bagasse drying by an experimental design using a tray dryer. In order to add-value to this product a kinetic study has been carried out. A central composite experimental design has been carried out to evaluate the influence of the operational variables: input air temperature (55; 65 e 75ºC); the drying air velocity (3.2; 4.6 e 6.0 m/s) and the fixed bed thickness (0.8; 1.2 e 1.6 cm) and as response variable the the moisture content (dry basis). The results showed that the diffusional Fick model fitted quite well the experimental data. The best condition found has been input air temperature of 75ºC, drying air velocity of 6.0 m/s as well as fixed bed thickness of 0.8 cm. The experimental design assay showed that the main effects as well as the second ones were significant at 95% confindance level. The best operational condition according to statistical planning was 75 oC input air temperature, 6.0 m.s-1 drying air velocity and 0.8 cm fixed bed thickness. In this case, the equilibrium moisture content (1.3% dry basis) occured at 220 minutes

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The rotary dryer is one of the most used equipments in processing industries. Its automatic control mode of operation is important specially to keep the moisture content of the final product in the desired value. The classical control strategies, like PID (proportional integral derivative) control, are largely used in the industrial sector because of its robustness and because they are easy to be implemented. In this work, a data acquisition system was implemented for monitoring the most relevant process variables, like: both inlet and outlet drying air temperature, dryer rotation, outlet air speed and humidity, and mass of the final product. Openloop tests were realized to identify a mathematical model able to represent the drying process for the rotary system. From this model, a PID controller was tuned using a direct synthesis method, assuming a first order trajectory. The PID controller was implemented in the system in order to control the inlet drying air temperature. By the end, closedloop tests (operating in automatic mode) were realized to observe the controller performance, and, after setting the best tune, experiments were realized using passion fruit seeds as raw material. The experiments realized in closedloop showed a satisfactory performance by the implemented control strategy for the drying air temperature of the rotary system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this research, the drying process of acerola waste was investigated by using a spouted bed drier. The process was conducted using high density polyethylene inert particles with the objective of producing an ascorbic acid-rich final product. The fruit waste was ground and used to prepare different water-maltodextrin suspensions. Initially, fluidynamical experiments were conducted in order to evaluate the feeding effect on the spouted bed drier fluidynamics behavior. The experimental planning 23 + 3 was used to investigate the effect of the following variables: solids concentration, drying air temperature, intermittence time, production efficiency, solids retention and product losses by elutriation of fine particles on drier walls. The effect of selected independent variables on the drier stability was also evaluated based on a parameter defined as the ratio between the feed suspension volume and the total inert particles volume. Finally, the powder quality was verified in experiments with fixed feed flow and varying air drying temperature, drying air velocity and intermittence time. It was observed that the suspension interferes in the spouted bed drier fluidynamics behavior, and higher air flow is necessary to stabilize the drier. The suspension also promotes the expansion of the spouted bed diameter, decreases the solid circulation and favors the air distribution at the flush area. All variables interfere in the spouted bed performance, and the solids concentration has a major effect on the material retention and losses. The intermittence time also has great effect on the stability and material retention. When it comes to production efficiency, the main effect observed was the drying air temperature. First order models were well adjusted to retention and losses data. The acerola powder presented ascorbic acid levels around 600 to 700 mg/100g. Similar moisture and ascorbic acid levels were obtained for powders obtained by spouted bed and spray drier. However, the powder production efficiency of the spray drier was lower when compared to spouted bed drier. When it comes to energetic analysis, the spray drier process was superior. The results obtained for spouted bed drier are promising and highly dependent on the operational parameters chosen, but in general, it is inferred that this drying process is adequate for paste and suspension drying

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work studies two methods for drying sunflower grains grown in the western region of Rio Grande do Norte, in the premises of the Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte - IFRN - Campus Apodi. This initiative was made because of the harvested grain during the harvest, being stored in sheds without any control of temperature, humidity etc. Therewith, many physical, chemical and physiological characteristics are compromised and grains lose much quality for oil production as their germination power. Taking into account that most of the stored grain is used for replanting, the studied methods include drying of grains in a thin layer using an oven with air circulation (fixed bed) and drying in a spouted bed. It was studied the drying of grains in natura, i.e., newly harvested. The fixed bed drying was carried out at temperatures of 40, 50, 60 and 70°C. Experiments in spouted bed were performed based on an experimental design, 2² + 3, with three replications at the central point, where the independent variables were grains load (1500, 2000 and 2500 g) and the temperature of the inlet air (70, 80, and 90 °C), obtaining the drying and desorption equilibrium isotherms. Previously, the characteristic curves of the bed were obtained. Both in the fixed bed as in the spouted bed, drying and desorption curves were obtained by weighing the grains throughout the experiments and measurements of water activity, respectively. The grains drying in the spouted bed showed good results with significant reduction of processing time. The models of FICK and PAGE were fitted to the experimental data, models which will represent the drying of grains both in the fixed bed as in the spouted bed. The desorption curves showed no influence of the processing temperature in the hygroscopic characteristics of the grains. The models of GAB, OSWIN and LUIKOV could well represent the desorption isotherms

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Green bean is considered as one of most traditional Brazilian Northeast dishes. Green beans drying preliminary experiments show that combine processes, fixed-bed/spouted bed, resulted in dehydrated beans with uniform humidity and the recovery of the beans properties after their rehydration. From this assays was defined an initial humidity suited for the spouted bed process. A fixed-bed pre-drying process until a level of 40% humidity gave the best results. The spouted bed characteristic hydrodynamic curves were presented for different beans loads, where changes in the respective beans physical properties were evidenced during the fluidynamic assay, due simultaneous drying process. One 22 factorial experimental design was carried out with three repetition in the central point, considering as entry variables: drying air velocity and temperature. The response variables were the beans brakeage, water fraction evaporated during 20 and 50 minutes of drying and the humidity ratio. They are presented still the modeling of the drying of the green beans in fine layer in the drier of tray and the modeling of the shrinking of the beans of the drying processes fixed-bed and spouted bed