33 resultados para Tanque séptico

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document aims to improve the quality of the production test in vertical tanks with free water drain pipes, through a device to control the draining system. This proposal consists of an interface detector close to the tank bottle and a control valve on the pipe-drain; they are attached to a remote supervisor system, which will be minimizing the human influence in the conclusion of the test result. And for more consciousness the work shows the importance of the wells production test in the attendance and diagnosis of the productive process, informing the large number of tests executed and problems of the procedure adopted in the field today. There are many possible sources of uncertainty in this kind of test as shown in the experiments realized in the field; the object prototype of this dissertation will be made in the field, based upon the definition of parameters and characteristics of the devices proposal. For a better definition of the draining process the action results of the assessment test are shown, especially changed some for the understand ing of the real process. It shows the proposal details and the configuration that will be used in the tank of Monte Alegre s field Production Station, explaining the interface detector kind and the control system. It is the base to a pilot project now in development, named as the new project classified in the status of the new technology and production improvement of PETROBRAS in Rio Grande do Norte and Ceará. This dissertation concludes that the automation of the conventional test with the draining system will bring benefits both economically as metrologically, because it reduces the uncertainty of the test procedures with free water draining, and also decreases the number of tests with problems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fucans is a name used for sulfated polysaccharides, which is most characteristic structure of the presence of sulfated L-fucose, are found in brown seaweed (Phaeophyceae) and echinoderms (sea urchins and sea cucumbers). These polysaccharides have been reported to possess anticoagulant, antitumor, anti-viral, anti-proliferative and anti-inflammatory activities. Therefore, in the present study was evaluate the effect of the fucan from the brown seaweed Spatoglossum schroederii in models of peritonitis and non-septic shock induced by zymosan, as well as in a murine model of colitis induces by DSS. So, the mice treatment by intravenous route with the fucan was able to reduce the exudate formation and the cell migration in the model of acute peritonitis induced by zymosan during the kinetic of 6, 24 and 48 hours. Similarly, in the model of non-septic shock induced by zymosan the fucan demonstrated a protector effect to inhibited the cellular migration to the peritoneo, to decrease the levels of IL-6 in the serum and in the peritoneal exudate, to attenuate the lose of weight in the mice; beside to reduce the serum levels of hepatic transaminases and as well as the liver injury. In the model of murine colitis, the treatment with the fucan reduced the lose of weight of the animals, decreased the levels of IL-17 and IFN- produced in the gut and decrease the intestinal lesion induced by DSS. In conclusion, the fucan used in this study presented a significant protector effect in the murine models of inflammation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the quality of raw milk from eight dairy farms in Rio Grande do Norte stored in a cooling tank , in order to evaluate methods for determining somatic cell counts (SCC). The Somaticell® kit and a portable Direct Cell Counter (DCC) were compared with each other and with the MilkoScanTM FT+ (FOSS Denmark), which uses Fourier Transform Infrared (FTIR) spectroscopy). Direct cell counter data were processed for somatic cell scores (log-transformed somatic cell count) and analyzed with the SAS®, statistical package , Statistical Analysis System, (SAS, INSTITUTE, 1998). Comparison of means and correlation of somatic cell scores were conducted using Pearson s correlation coefficient and the Tukey Test at 1 %. No significant difference was observed for comparison of means. The correlation between somatic cell scores was significant, that is, 0.907 and 0.876 between the MilkoScanTM FT+ and the Somaticell® kit and Direct Cell Count (DCC) respectively, and 0.943 between the Somaticell® kit and Direct Cell Count (DCC). The methods can be recommended for monitoring the quality of raw milk kept in a cooling tank in the production unit

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tratar-se-á de um estudo metodológico, com abordagem quantitativa; baseado no referencial metodológico da técnica Delphi, com objetivo de construir e validar um protocolo clínico para assistência do enfermeiro ao paciente séptico na Unidade de Terapia Intensiva. A proposta metodológica seguiu duas etapas: elaboração do instrumento por meio da revisão integrativa da literatura e validação de conteúdo do protocolo. O estudo foi aprovado pelo Comitê de Ética em Pesquisa, mediante o Parecer CAAE 41873314.5.0000.5537. O universo amostral foi composto por profissionais enfermeiros, considerados peritos, doutores ou mestres na área da saúde, com experiência em alta complexidade e/ ou estudos de validação de instrumento/protocolo, selecionados por meio da Plataforma Lattes. Referente à primeira etapa elaborou-se um instrumento composto pela caracterização profissional dos peritos; e baseado em evidência científica e nas diretrizes do Surviving Sepsis Campaign, contemplando três tópicos assistenciais ao paciente com sepse, a saber: Triagem para Sepse- Reconhecimento das Manifestações Clínicas; Pacote de Ressuscitação Inicial (Controle das Primeiras 6 Horas); Tratamento de Suporte. A segunda etapa caracterizou-se na validação de conteúdo do instrumento para elaboração final do protocolo, utilizando à técnica Delphi, em duas fases. No que concernem as variáveis referentes ao estudo, na 1ª fase de Delphi, 34 peritos avaliaram o instrumento composto por 18 itens, no período de maio a julho de 2015, e os dados foram analisados pela estatística descritiva (frequência, média, mediana e desvio padrão) e pelo Índice de Validade de Conteúdo (IVC), demonstrando um IVC extremamente satisfatório para 15 itens, com total de 0,79, obtendo assim, a reformulação e refinamento do conteúdo do instrumento. Na segunda fase de Delphi, entre julho e agosto de 2015, participaram 26 peritos, e utilizou-se o percentual de concordância acima de 75% para as variáveis consideradas pertinentes ao protocolo de cuidados ao paciente séptico em UTI, obtendo nesta fase, o percentual de concordância de 95%. O protocolo foi concluído com 15 itens, sendo respaldado e modificado, baseado em evidência científica, nas diretrizes internacionais e nas sugestões dos peritos. A utilização do protocolo proposto poderá contribuir para a prática clínica do enfermeiro ao paciente séptico na Unidade de Terapia Intensiva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tratar-se-á de um estudo metodológico, com abordagem quantitativa; baseado no referencial metodológico da técnica Delphi, com objetivo de construir e validar um protocolo clínico para assistência do enfermeiro ao paciente séptico na Unidade de Terapia Intensiva. A proposta metodológica seguiu duas etapas: elaboração do instrumento por meio da revisão integrativa da literatura e validação de conteúdo do protocolo. O estudo foi aprovado pelo Comitê de Ética em Pesquisa, mediante o Parecer CAAE 41873314.5.0000.5537. O universo amostral foi composto por profissionais enfermeiros, considerados peritos, doutores ou mestres na área da saúde, com experiência em alta complexidade e/ ou estudos de validação de instrumento/protocolo, selecionados por meio da Plataforma Lattes. Referente à primeira etapa elaborou-se um instrumento composto pela caracterização profissional dos peritos; e baseado em evidência científica e nas diretrizes do Surviving Sepsis Campaign, contemplando três tópicos assistenciais ao paciente com sepse, a saber: Triagem para Sepse- Reconhecimento das Manifestações Clínicas; Pacote de Ressuscitação Inicial (Controle das Primeiras 6 Horas); Tratamento de Suporte. A segunda etapa caracterizou-se na validação de conteúdo do instrumento para elaboração final do protocolo, utilizando à técnica Delphi, em duas fases. No que concernem as variáveis referentes ao estudo, na 1ª fase de Delphi, 34 peritos avaliaram o instrumento composto por 18 itens, no período de maio a julho de 2015, e os dados foram analisados pela estatística descritiva (frequência, média, mediana e desvio padrão) e pelo Índice de Validade de Conteúdo (IVC), demonstrando um IVC extremamente satisfatório para 15 itens, com total de 0,79, obtendo assim, a reformulação e refinamento do conteúdo do instrumento. Na segunda fase de Delphi, entre julho e agosto de 2015, participaram 26 peritos, e utilizou-se o percentual de concordância acima de 75% para as variáveis consideradas pertinentes ao protocolo de cuidados ao paciente séptico em UTI, obtendo nesta fase, o percentual de concordância de 95%. O protocolo foi concluído com 15 itens, sendo respaldado e modificado, baseado em evidência científica, nas diretrizes internacionais e nas sugestões dos peritos. A utilização do protocolo proposto poderá contribuir para a prática clínica do enfermeiro ao paciente séptico na Unidade de Terapia Intensiva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document aims to improve the quality of the production test in vertical tanks with free water drain pipes, through a device to control the draining system. This proposal consists of an interface detector close to the tank bottle and a control valve on the pipe-drain; they are attached to a remote supervisor system, which will be minimizing the human influence in the conclusion of the test result. And for more consciousness the work shows the importance of the wells production test in the attendance and diagnosis of the productive process, informing the large number of tests executed and problems of the procedure adopted in the field today. There are many possible sources of uncertainty in this kind of test as shown in the experiments realized in the field; the object prototype of this dissertation will be made in the field, based upon the definition of parameters and characteristics of the devices proposal. For a better definition of the draining process the action results of the assessment test are shown, especially changed some for the understand ing of the real process. It shows the proposal details and the configuration that will be used in the tank of Monte Alegre s field Production Station, explaining the interface detector kind and the control system. It is the base to a pilot project now in development, named as the new project classified in the status of the new technology and production improvement of PETROBRAS in Rio Grande do Norte and Ceará. This dissertation concludes that the automation of the conventional test with the draining system will bring benefits both economically as metrologically, because it reduces the uncertainty of the test procedures with free water draining, and also decreases the number of tests with problems

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the sediment preference of L. vannamei shrimp. It was observed shrimp visit frequency, swimming and burying behaviour at different sediment compositions for 24h. Juvenile (0.93 ± 0.29g) and sub-adult shrimps (10.0 ± 1.18g) were obtained from the aquaculture station at Universidade Federal Rural do Semi-Árido UFERSA, and held in a plastic tank (water volume 500 L) supplied with aerated water and kept at constant temperature, pH, and salinity. Shrimp was fed by commercial shrimp dry food. The experimental substrates were composed by A: medium sand + thick sand + very thick sand + gravel; B: very fine sand + fine sand; and C: silt + clay. Thus, six different substrate combinations were tested: A, B, C, A+B, A+C, B+C. To test preference, it was used a cylindrical tank (40 l) divided into six differently substrate compartments. A single shrimp was introduced each tank and the frequency at which this shrimp visited each compartment was recorded over a 24h study period. It was tested 54 shrimp (18 sub-adult males, 18 subadult females and 18 juveniles). For each trial, sediment and water were changed to avoid pheromones and residues influence. Shrimp were weighted and sub-adults were divided by sex: males present petasma and females present thelycum. Data were collected on the experimental day at 19:30; 20:30; 00:30; 1:30; 05:30; 06:30; 13:30 and 14:30 h. At each time point, shrimp were observed for 20-min periods, in which we noted down which compartment the shrimp was occupying at 2-min intervals. Thus, for each period we had eleven observations (88 observations per day). For observations at night, it was used dim red light that did not affect shrimp behaviour. At each 20-min period, it was observed visit frequency in each substrate, if shrimp was burred or not or if it was swimming. There was not significant difference between light and dark burry activity for females. Swimming activity was significantly higher at night, mainly at 00:30 and 01:30 h. All L. vannamei shrimp showed preference for sediment B. This animal presents cyclic activity, spends the day light period buried and swims at night

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents a proposal to detect interface in atmospheric oil tanks by installing a differential pressure level transmitter to infer the oil-water interface. The main goal of this project is to maximize the quantity of free water that is delivered to the drainage line by controlling the interface. A Fuzzy Controller has been implemented by using the interface transmitter as the Process Variable. Two ladder routine was generated to perform the control. One routine was developed to calculate the error and error variation. The other was generate to develop the fuzzy controller itself. By using rules, the fuzzy controller uses these variables to set the output. The output is the position variation of the drainage valve. Although the ladder routine was implemented into an Allen Bradley PLC, Control Logix family it can be implemented into any brand of PLCs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento das grandes cidades tem gerado um dos maiores desafios ambientais enfrentados na atualidade, que é a gestão eficaz de resíduos sólidos. A grande variedade e quantidade dos resíduos produzidos diariamente, tem tornado a destinação ecologicamente correta e sustentável destes materiais cada vez mais difícil. Dentre os vários resíduos produzidos diariamente destacam-se os lodos oriundos de estações de tratamento de esgotos, denominados de lodos de esgoto, cuja destinação final segura tem sido discutida mundialmente em diversos estudos, tendo em vista que a tendência de geração deste tipo de resíduo tende a crescer com o aumento do saneamento das cidades. Uma forma amplamente difundida nos países desenvolvidos para destinação dos lodos de esgoto é a incineração destes materiais para posterior envio das cinzas geradas neste processo a aterros sanitários. Porém, tem-se estudado formas alternativas de disposição, destacando-se a utilização destas cinzas como adição mineral em concretos e argamassas de cimento Portland. Sabe-se que o desempenho de resíduos de incineração como adição mineral em matrizes cimentícias, depende em grande parte da capacidade de atuação destes materiais como elementos pozolânicos ou como fileres, podendo estas características serem influenciadas pela temperatura de queima ao qual estes resíduos foram submetidos. Neste sentido, verificou-se com esta pesquisa a influência da temperatura empregada na queima dos lodos sépticos no índice de atividade pozolânica (IAP) das cinzas geradas como resíduo deste processo, aqui denominadas de cinzas de lodo séptico (CLS), sendo em seguida, avaliadas as implicações técnicas e microestruturais da utilização deste resíduo em teores de 10%, 20% e 30% como adição mineral em concretos de cimento Portland. Os resultados obtidos demonstraram não haver alterações significativas no IAP das CLS em decorrência da temperatura utilizada durante o processo de queima dos lodos de esgoto. Além disso, verificou-se que embora a utilização das CLS tenham provocado diminuição da trabalhabilidade dos concretos para todos os teores de incorporação, estas melhoraram a resistência mecânica à compressão, o índice de vazios, a absorção de água e o comportamento microestrutural dos concretos contendo 10% e 20% de resíduo

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new multi-model technique of dentification in ANFIS for nonlinear systems. In this technique, the structure used is of the fuzzy Takagi-Sugeno of which the consequences are local linear models that represent the system of different points of operation and the precursors are membership functions whose adjustments are realized by the learning phase of the neuro-fuzzy ANFIS technique. The models that represent the system at different points of the operation can be found with linearization techniques like, for example, the Least Squares method that is robust against sounds and of simple application. The fuzzy system is responsible for informing the proportion of each model that should be utilized, using the membership functions. The membership functions can be adjusted by ANFIS with the use of neural network algorithms, like the back propagation error type, in such a way that the models found for each area are correctly interpolated and define an action of each model for possible entries into the system. In multi-models, the definition of action of models is known as metrics and, since this paper is based on ANFIS, it shall be denominated in ANFIS metrics. This way, ANFIS metrics is utilized to interpolate various models, composing a system to be identified. Differing from the traditional ANFIS, the created technique necessarily represents the system in various well defined regions by unaltered models whose pondered activation as per the membership functions. The selection of regions for the application of the Least Squares method is realized manually from the graphic analysis of the system behavior or from the physical characteristics of the plant. This selection serves as a base to initiate the linear model defining technique and generating the initial configuration of the membership functions. The experiments are conducted in a teaching tank, with multiple sections, designed and created to show the characteristics of the technique. The results from this tank illustrate the performance reached by the technique in task of identifying, utilizing configurations of ANFIS, comparing the developed technique with various models of simple metrics and comparing with the NNARX technique, also adapted to identification