5 resultados para TRANSIENTS

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Agência Nacional de Energia Elétrica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The occurrence of transients in electrocardiogram (ECG) signals indicates an electrical phenomenon outside the heart. Thus, the identification of transients has been the most-used methodology in medical analysis since the invention of the electrocardiograph (device responsible for benchmarking of electrocardiogram signals). There are few papers related to this subject, which compels the creation of an architecture to do the pre-processing of this signal in order to identify transients. This paper proposes a method based on the signal energy of the Hilbert transform of electrocardiogram, being an alternative to methods based on morphology of the signal. This information will determine the creation of frames of the MP-HA protocol responsible for transmitting the ECG signals through an IEEE 802.3 network to a computing device. That, in turn, may perform a process to automatically sort the signal, or to present it to a doctor so that he can do the sorting manually

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The continuous gas lift method is the main artificial lifting method used in the oil industry for submarine wells, due to its robustness and the large range of flow rate that the well might operate. Nowadays, there is a huge amount of wells producing under this mechanism. This method of elevation has a slow dynamics due to the transients and a correlation between the injected gas rate and the of produced oil rate. Electronics controllers have been used to adjust many parameters of the oil wells and also to improve the efficiency of the gas lift injection system. This paper presents a intelligent control system applied to continuous gas injection in wells, based in production s rules, that has the target of keeping the wells producing during the maximum period of time, in its best operational condition, and doing automatically all necessary adjustments when occurs some disturbance in the system. The author also describes the application of the intelligent control system as a tool to control the flow pressure in the botton of the well (Pwf). In this case, the control system actuates in the surface control valve

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four areas are known as of frequent usage by Guiana dolphins (Sotalia guianensis) in the south coast of Rio Grande do Norte state, northeast Brazil: Tabatinga, Pipa, Lagoa de Guaraíras and Baia Formosa. This extension of 40 km of shoreline is under increasing anthropogenic impacts due to continuous development of the coastal areas and vessel traffic. The objective of this study was to investigate aspects of population biology and habitat use of the population of Sotalia guianensis in the south coast of Rio Grande do Norte. It was applied the photo-identification technique and posterior methods of capture-recapture for population estimation (POPAN extension in MARK). The distribution, movement and site fidelity of the dolphins were analyzed trough the geographic information system (GIS) and group characteristics and behavior trough non-parametric statistics. Field work was conducted on board a 10m motor vessel from March 2008 to March 2009. Photo-identification effort was 329h with 113h of direct observation of the dolphins. The population estimatives for each area: Tabatinga: 75 (63-92); Pipa 105 (88-129); Lagoa de Guaraíras: 27 (18-54) e Baia Formosa: 112 (89-129) individuals. Total population estimative was: 223 (192 a 297). High site fidelity was detected for only part of the population (<15%) as low site fidelity and transients individuals were also detected (>20%). It was observed frequent movements between Tabatinga, Lagoa de Guaraíras and Pipa, but not Baía Formosa. This suggests a division in two communities along this shore extension: one in Pipa and other in Baía Formosa. Group size was small, most groups with up to 10 dolphins. The areas were use intensively, only in Lagoa de Guaraíras dolphins were not seen in all field trips. Lagoa de Guaraíras is an area used by small groups exclusively for foraging. In Tabatinga and Pipa dolphins concentrated close to the shore, in the inner sector of the area and the main activity is also foraging. Significant larger groups were seen in socializing behavior but there was no difference in group size between the inner and external sectors of the area. The presence of calves and juveniles were significant greater in the inner areas of Tabatinga and Pipa, confirming the hypothesis that these beaches are also used for parental care. In Baia Formosa dolphins concentrated in the outer sector and foraging was also predominant. Significant larger groups were seen in the outer sector, mainly engaged in mixed behaviors of travel/foraging, possibly in some kind of group foraging. Calves and juveniles were significant more present in the outer sector where group size was also larger. In general there was no difference in area usage and period of the day. Sotalia guianensis has characteristics that make the species vulnerable to human activities such as small population concentrated in patches of suitable habitats restrict to coastal areas. We hope that this study bring new information for the species and help for the adequate management of the area in order to assure the presence of the dolphins as well as its behavior pattern and gene flow betweencommunities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A typical electrical power system is characterized by centr alization of power gene- ration. However, with the restructuring of the electric sys tem, this topology is changing with the insertion of generators in parallel with the distri bution system (distributed gene- ration) that provides several benefits to be located near to e nergy consumers. Therefore, the integration of distributed generators, especially fro m renewable sources in the Brazi- lian system has been common every year. However, this new sys tem topology may result in new challenges in the field of the power system control, ope ration, and protection. One of the main problems related to the distributed generati on is the islanding formation, witch can result in safety risk to the people and to the power g rid. Among the several islanding protection techniques, passive techniques have low implementation cost and simplicity, requiring only voltage and current measuremen ts to detect system problems. This paper proposes a protection system based on the wavelet transform with overcur- rent and under/overvoltage functions as well as infomation of fault-induced transients in order to provide a fast detection and identification of fault s in the system. The propo- sed protection scheme was evaluated through simulation and experimental studies, with performance similar to the overcurrent and under/overvolt age conventional methods, but with the additional detection of the exact moment of the fault.