3 resultados para Sewage purification nutrient removal

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we carried out the study of Eriochrome black T removal using expanded perlite modified orthophenanthroline by adsorption technique. The study of the adsorption process was performed by investigating the effect of the initial dye concentration, contact time and pH range of the solution (acidic and alkaline) in the adsorption process, for a so-called synthetic effluent (aqueous solution of black eriochrome T) and a real effluent (generated from the test for determining the water hardness, by complexation titration). The materials were characterized by Thermogravimetry / Differential Thermal Analysis (TG / DTA), absorption spectroscopy in the infrared (IR), X-ray Diffraction (XRD) and scanning electron microscopy (SEM). By analysis of XRD observed thinking on orthophenanthroline the modified expanded perlite. And by IR analysis showed an increase in intensity and a detailed enlargement of the absorption band related to the axial deformation of the OH bond of silanol groups of perlite (Si-OH). In the equilibration time of the study, in the evaluated time range (5-230 min) was not possible to observe the existence of a balance of time, probably attributed to the type of interaction between the Eriochrome black-T and the expanded perlite modified orthophenanthroline, being an interaction of surface origin. In the study effect of the initial concentration of the adsorbate in the case 2,0x10-4 mol / L natural pH (pH 5) gave the highest removal percentage value of eriochrome T black color with 63.74 % removal in 20 minutes of contact. In evaluating the effect of varying the pH of Eriochrome black T solution in the adsorption process, it was found that the more acidic the environment, the greater the percentage stain removal, being a result of acid-base interaction between the adsorbate and the adsorbent. In T Eriochrome black removal study in real effluent we used the optimized conditions by studying with synthetic sewage. The dye removal at pH 10, natural pH of the effluent was no significant reaching the maximum amount of color removal percentage of 8.12%, obtained already at pH 3 with maximum color removal 100.00% of color, once more proving that eriochrome black T and effectively interact better with the adsorbent at acid pH values (pH 5 or 3), and most efficiently at pH 3. thus one can mention that the perlite expanded (an amorphous aluminosilicate naturally acid) modified with orthophenanthroline (one Bronsted base) consists of a master and effective removal of coloring material in the acid-type aqueous solution, the conditions expressed in this study, can be applied as an adsorbent of this dye also mums real effluent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.