3 resultados para Public building

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years, as part of the expansion process of its activities, the Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte – IFRN (Federal Institute for Education, Science and Technology of the State of Rio Grande do Norte – IFRN) detected the need to hire more employees for the institution. This expansion process, a policy of the Federal Government, together with the increase of human resources, required the construction of an adequate facility in the municipality of São Gonçalo do Amarante-RN, for training and qualification and as a means of better enabling its personnel. Along with this policy, the Federal Government is also deeply concerned that its buildings be environmentally friendly. This study deals with this subject matter, as it develops an architectural design of a public building with an emphasis upon the reduction of energy consumption, through the study of energy performance factors such as defined by Carneiro (1988) and adapted by the author of the present study. It is known that residential, commercial and public buildings represent about 45 % of energy consumption in Brazil. That is why it is necessary to consider the reduction of such consumption in buildings, as well as the role that professionals, especially architects, play in this issue. The most effective participation in this regard in the field of architecture occurs in the design phase. However, the architectural solution proposed here goes beyond the energy performance factors, since it also involves other aspects, such as the definition of the concept, the parti and the spatial solution itself. In this sense, the architectural project of the Centro de Treinamento dos Servidores do IFRN - CTSIFRN (Training Center for IFRN Personnel – CTSFIRN) is particularly fitting as a subject for research at the Professional Master Program at PPGAU/UFRN, which is devoted to research on architecture, design and the environment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN