15 resultados para Prótese Total

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The maintenance of masticatory function is especially important for patients who wear complete dentures due to the limitations of this type of prosthesis. Thus, the bilateral balanced occlusion (BBO) is used to achieve, besides other advantages, greater masticatory efficiency. However, analyzing critically the literature, it is observed that there is not enough scientific evidence that support the BBO as the most appropriate occlusal concept in complete dentures. This way, the purpose of the present study was to verify if complete dentures wearers with BBO present better masticatory efficiency and capacity than those with canine guidance (CG). A double-blind controlled crossover clinical trial was conducted. The sample was made of 24 completely edentulous patients. The subjects wore sets of complete dentures with both occlusal concepts for equal periods of 3 months. Objective data were collected through the masticatory efficiency test, performed by the colorimetric method, in which capsules of a synthetic material enclosing fuchsine- containing granules were used. Subjective data were recorded by patient´s ratings of their chewing function, which is the masticatory ability. No significant statistical difference was found for masticatory efficiency (p=0,0952) and masticatory ability (x2=0,5711/ p=0,4498) between the two occlusal concepts studied, as well as there was no correlation between these two variables (p=0,2985). Based on these results, it seems reasonable to use CG for the setup of complete dentures, since it is an easier and quicker technical procedure, until that future researches can come to complement this question

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The rehabilitation of edentulous patients is one of the main challenges of Dentistry. Objective: To assess the satisfaction and the impact of oral health on quality of life of patients rehabilitated with conventional complete dentures in both arcades. Method: A clinical trial with 25 patients rehabilitated with CCD was conducted. The impact of oral health in individuals quality of life was evaluated through the Brazilian version of the OHIP-Edent and the patient satisfaction was evaluated using a specific questionnaire. The instruments were applied before and 3 months after rehabilitation. Results: There was a statistically significant improvement (p <0.001) on the impact of the quality of life of the denture users after the new rehabilitation. The analysis of 4 OHIP domains also showed statistically significant improvement (p <0.001). The final overall satisfaction with the dentures was statistically superior to initial satisfaction (p <0.001). The analysis of the specific aspects of satisfaction with CCD after 3 months of rehabilitation also showed significant results in the improvement of every aspect. Conclusion: Patients disappointed with their dentures, have their quality of life improved after the new rehabilitation, reducing the negative impact of the prostheses on oral health, and improving their satisfaction with the rehabilitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents a simple, fast and low cost technique for fabrication new conventional dentures from the duplication of old prosthesis in use by the patient. Colorless acrylic resin was poured into the moulds obtained by duplication of prosthesis. With the replicas obtained a functional impressions using polyether should be performed and they are stabilized with occlusal registration in acrylic resin. The molds need to be castings and mounted on an semi-adjustable articulator. The artificial teeth are positioned with the assistance of a guide made condensation silicone to reproduce the positioning of the teeth of the old prosthesis and fixed with wax 7. After approval of the teeth on the trial in wax, without adjustment of the planes, the prosthesis may be processed in the laboratory. After occlusal adjustment in the articulator the same can be installed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Buscar na literatura evidências científicas que suportem os benefícios da individualização da curva de compensação em prótese total, pela técnica do desgaste de Paterson, em relação à curva de compensação não individualizada. Metodologia: Realizou-se, em Dezembro de 2009, uma revisão sistemática da literatura nas bases de dados MEDLINE, LILACS e BBO com os termos “prótese total” e “oclusão”. Para abranger uma maior quantidade de dados, realizou-se uma busca manual através das referências dos artigos inicialmente selecionados. Resultados: Obteve-se 1273 referências na base dados MEDLINE, 64 na LILACS e 103 na BBO, num total de 1440 referências. Dessas, apenas 24 tratavam do assunto “curva de compensação”, as quais somaram-se mais 13 artigos selecionados manualmente. Conclusão: A partir dos resultados obtidos, conclui-se que não existem dados suficientes que comprovem clinicamente os benefícios da individualização da curva de compensação em relação às próteses totais com curva de compensação não individualizada. Ensaios clínicos controlados e randomizados são necessários para que se possa determinar qual o procedimento mais adequado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Buscar na literatura evidências científicas que suportem os benefícios da individualização da curva de compensação em prótese total, pela técnica do desgaste de Paterson, em relação à curva de compensação não individualizada. Metodologia: Realizou-se, em Dezembro de 2009, uma revisão sistemática da literatura nas bases de dados MEDLINE, LILACS e BBO com os termos “prótese total” e “oclusão”. Para abranger uma maior quantidade de dados, realizou-se uma busca manual através das referências dos artigos inicialmente selecionados. Resultados: Obteve-se 1273 referências na base dados MEDLINE, 64 na LILACS e 103 na BBO, num total de 1440 referências. Dessas, apenas 24 tratavam do assunto “curva de compensação”, as quais somaram-se mais 13 artigos selecionados manualmente. Conclusão: A partir dos resultados obtidos, conclui-se que não existem dados suficientes que comprovem clinicamente os benefícios da individualização da curva de compensação em relação às próteses totais com curva de compensação não individualizada. Ensaios clínicos controlados e randomizados são necessários para que se possa determinar qual o procedimento mais adequado.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo objetivou analisar as características epidemiológicas das condições de saúde bucal de 98 idosos de uma Instituição de Longa Permanência para Idosos (ILPI) e de 125 participantes de Grupos de Convivência, de bairros periféricos, socialmente semelhantes, de Fortaleza, Ceará, Brasil, para orientação do tratamento odontológico. Investigou-se a autopercepção em saúde bucal desses idosos a fim de realizar uma avaliação comparativa entre eles e com os levantamentos epidemiológicos de base nacional (SB Brasil) e de base estadual (SB Ceará). Devido a alguns idosos da ILPI recusarem o tratamento dentário e a identificação do elevado percentual de demenciados, optou-se por realizar uma avaliação cognitiva, o Mini Exame do Estado Mental (MEEM) visando identificar os aptos à reabilitação oral. Métodos: abordagem epidemiológica do tipo transversal, sendo a coleta de dados realizada por cinco examinadores, utilizando os critérios recomendados pela OMS (1997). Resultados: O CPO-D médio encontrado na ILPI, foi de 29,88, com predomínio do componente perdido (93,27%) enquanto o CPO-D médio dos não institucionalizados fixou-se em 30,17, com predomínio do componente perdido (63,70%). Também se avaliou o uso e a necessidade de prótese dentária: dos residentes na ILPI, 10,20% usavam prótese superior e 3,06%, inferior; 94,90% necessitavam de prótese superior e 97,96% de inferior; sendo a prótese total foi o tipo mais prevalente, 88,78% para ambos os arcos. O percentual do uso de prótese dos não institucionalizados foi 71,20% no arco superior, sendo 66,40% prótese total; já para o arco inferior, 32,80%, das quais 31,20% era prótese total. No presente estudo, tanto para uso quanto para necessidade, considerando ambos os arcos, a diferença entre os idosos institucionalizados e não institucionalizados foi estatisticamente significativa pelo teste Qui - quadrado (p<0,001). Como resultado do MEEM, observou-se deterioração cognitiva (escore ≤ 12) em 37,25% dos entrevistados, bem como um declínio cognitivo com o avanço da idade. Conclusões: Os resultados apontam que há um maior percentual de uso de prótese total no arco superior e maior frequência quanto à ausência de próteses de qualquer tipo no arco inferior. Evidenciou-se que os idosos pesquisados foram submetidos a tratamento mutilador e, como consequência necessitam de reabilitação oral, o que pressupõe a necessidade de políticas públicas para que isso ocorra efetivamente. Os participantes deste estudo caracterizam-se por uma autopercepção positiva da sua saúde bucal, a despeito das condições clínicas insatisfatórias e de precária saúde bucal, com acentuada prevalência de cárie dentária e edentulismo. O MEEM revelou deficiência cognitiva na maioria dos idosos, confirmando que a sua aplicação, previamente à reabilitação oral pode evitar desperdícios financeiros.Tais achados refletem a necessidade de implantação de políticas reabilitadoras em saúde bucal voltadas para o idoso; baseadas na perspectiva da integralidade como princípio doutrinário do Sistema Único de Saúde, o que redundaria numa melhor qualidade de vida, tanto pela melhor mastigação, digestão e nutrição, pelo maior aproveitamento dos alimentos, quanto pelo favorecimento à comunicação, pela dicção e fala, contribuindo para a socialização e consequente elevação da autoestima dessa clientela.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Visto que indicadores de prognóstico são uma ferramenta importante para a seleção de pacientes a serem tratados com prótese total, este estudo investigou a influência da forma e da resiliência do rebordo alveolar mandibular sobre a retenção e estabilidade de próteses totais convencionais. Noventa e três pacientes desdentados portadores de próteses totais superior e inferior compuseram a amostra. Os dados foram coletados quanto a forma e resiliência do rebordo mandibular. As próteses foram avaliadas para a retenção e estabilidade utilizando-se uma ferramenta objetiva e reproduzível. As associações entre as características clínicas do rebordo alveolar mandibular e retenção e estabilidade das próteses foram analisados por meio dos testes qui-quadrado e exato de Fisher (α = 0.05). Observou-se associação significativa entre a forma do rebordo e a estabilidade da prótese (p <0,05), enquanto que a resiliência foi associada significativamente com a retenção (p <0,001). Baseando-se nos resultados, a resiliência e forma do rebordo mandibular influenciaram, respectivamente, a retenção e estabilidade de próteses totais convencionais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.