5 resultados para Plattsburg, Battle of, Plattsburgh, N.Y., 1814.
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The biodistribution of sodium pertechnetate, the most used radiopharmaceutical in nuclear medicine, has not been studied in details after bariatric surgery. The objective was to investigate the effect of Roux-en-Y gastric bypass (RYGB) on biodistribution of sodium pertechnetate (Na99mTc-) in organs and tissues of rats. Methods: Twelve rats were randomly divided into two groups of 6 animals each. The RYGB group rats were submitted to the Roux-en-Y gastric bypass and the control group rats were not operated. After 15 days, all rats were injected with 0.1mL of Na99mTc- via orbital plexus with average radioactivity of 0.66 MBq. After 30 minutes, liver, stomach, thyroid, heart, lung, kidney and femur samples were harvested, weighed and percentage of radioactivity per gram (%ATI/g) of each organ was determined by gama counter Wizard Perkin-Elmer. We applied the Student t test for statistical analysis, considering p<0.05 as significant. Results: Significant reduction in mean %ATI/g was observed in the liver, stomach and femur in the RYGB group animals, compared with the control group rats (p<0.05). In other organs no significant difference in %ATI/g was observed between the two groups. Conclusion: This work contributes to the knowledge that the bariatric surgery RYGB modifies the pattern of biodistribution of Na99mTc
Resumo:
The biodistribution of sodium pertechnetate, the most used radiopharmaceutical in nuclear medicine, has not been studied in details after bariatric surgery. The objective was to investigate the effect of Roux-en-Y gastric bypass (RYGB) on biodistribution of sodium pertechnetate (Na99mTc-) in organs and tissues of rats. Methods: Twelve rats were randomly divided into two groups of 6 animals each. The RYGB group rats were submitted to the Roux-en-Y gastric bypass and the control group rats were not operated. After 15 days, all rats were injected with 0.1mL of Na99mTc- via orbital plexus with average radioactivity of 0.66 MBq. After 30 minutes, liver, stomach, thyroid, heart, lung, kidney and femur samples were harvested, weighed and percentage of radioactivity per gram (%ATI/g) of each organ was determined by gama counter Wizard Perkin-Elmer. We applied the Student t test for statistical analysis, considering p<0.05 as significant. Results: Significant reduction in mean %ATI/g was observed in the liver, stomach and femur in the RYGB group animals, compared with the control group rats (p<0.05). In other organs no significant difference in %ATI/g was observed between the two groups. Conclusion: This work contributes to the knowledge that the bariatric surgery RYGB modifies the pattern of biodistribution of Na99mTc
Resumo:
The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic
Resumo:
ln this work, planar quasi- Y agi antennas are investigated based on the concept of the classic Y agi_Uda antennas. These antennas represent improvements on the topologies of the antennas existing printed because they present characteristics of broad bandwidth, excellent radiation diagrams and simple construction. New configurations are adapted for the driver of the antennas, introducing patches elements into the driver. These new configurations are named Patches Elements Anteonas (PEA). This adaptation is obtained from simulations that are executed usiog the software C8T Microwave 8tudio 5. After doing the optimizations, procedures for construction and measurement ofthe prototypes are executed in order to improve the performance of the antennas in such way that they could be used in wireless communication applications, such as Bluetooth, WLAN' s and Wi-Fi. Next, the quasi- Y agi antennas are studied in order to implement them in arrangements. The arrangements construction is based 00 the best driver configuration of the antenna developed in this work. First, a linear arrangement composed by two elements of quasi¬Yagi antennas is constructed in such way that the radiation characteristics and the mutual coupling effects could be analyzed. After that, a 90° angle arrangement composed by two elements is studied to observe the effect of circular polarization. Experiments are executed in order to evaluate the arrangements performance. The experimental results show that the analysis made in this work is efficient and accurate. The numerical values obtained for the analyzed parameters of each structure developed are compared with the experimental values. 80, it is possible to observe a good concordance between them. Finally, some future works proposals are presented
Resumo:
This work presents the design and construction of an X-Y table of two degrees of freedom, as well as the development of a fuzzy system for its position and trajectory control. The table is composed of two bases that move perpendicularly to each other in the horizontal plane, and are driven by two DC motors. Base position is detected by position sensors attached to the motor axes. A data acquisition board performs the interface between a laptop and the plant. The fuzzy system algorithm was implemented in LabVIEW® programming environment that processes the sensors signals and determines the control variables values that drive the motors. Experimental results using position reference signals (step type signal) and straight and circular paths reference signals are presented to demonstrate the dynamic behavior of fuzzy system