7 resultados para Performance-based regulation (PBR)

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The issue of creating productions of hybrid matrices has demanded, for more than three decades, the attention of several theater theorists (COHEN: 1995; LEHMANN: 2007). The study of philosophers (DELEUZE & GUATTARI: 1995) has contributed for new concepts of the scene. These artistic practices, depending on the context, have been generating, more and more, new ways of staging. I will discuss the contamination caused by Antonin Artaud in contemporary theater, and the theater s infection by the performance, based on the thought of Barbara Browning (1995), from its capacity to penetrate and invade territories, and installs a new system. I affirm that the Totem Group (Recife PE) was contaminated by the performance and analyze two performative plays of the group, their points of convergence and separation. The first one is Ita, the search for the origin, the animal devir; the second is Caosmopolita, the body as a reflex of urbanity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The issue of creating productions of hybrid matrices has demanded, for more than three decades, the attention of several theater theorists (COHEN: 1995; LEHMANN: 2007). The study of philosophers (DELEUZE & GUATTARI: 1995) has contributed for new concepts of the scene. These artistic practices, depending on the context, have been generating, more and more, new ways of staging. I will discuss the contamination caused by Antonin Artaud in contemporary theater, and the theater s infection by the performance, based on the thought of Barbara Browning (1995), from its capacity to penetrate and invade territories, and installs a new system. I affirm that the Totem Group (Recife PE) was contaminated by the performance and analyze two performative plays of the group, their points of convergence and separation. The first one is Ita, the search for the origin, the animal devir; the second is Caosmopolita, the body as a reflex of urbanity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes the design, the performance evaluation and a methodology for tuning the initial MFs parameters of output of a function based Takagi-Sugeno-Kang Fuzzy-PI controller to neutralize the pH in a stirred-tank reactor. The controller is designed to perform pH neutralization of industrial plants, mainly in units found in oil refineries where it is strongly required to mitigate uncertainties and nonlinearities. In addition, it adjusts the changes in pH regulating process, avoiding or reducing the need for retuning to maintain the desired performance. Based on the Hammerstein model, the system emulates a real plant that fits the changes in pH neutralization process of avoiding or reducing the need to retune. The controller performance is evaluated by overshoots, stabilization times, indices Integral of the Absolute Error (IAE) and Integral of the Absolute Value of the Error-weighted Time (ITAE), and using a metric developed by that takes into account both the error information and the control signal. The Fuzzy-PI controller is compared with PI and gain schedule PI controllers previously used in the testing plant, whose results can be found in the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation aims at characterizing the practices as well as the effects of a teacher s feedback in oral conversation interaction with students in an English Language classroom at a Primary School, 6th Grade in Açu/RN, Brazil. Therefore, this study is based on Vygotsky s (1975) and Bruner´s (1976) researches, which state that the learning process is constructed through interaction between a more experienced individual (teacher, parents and friends) and a learner who plays an active role, a re-constructor of knowledge. It is also based on Ur´s (2006) and Brookhart s (2008) studies (among other authors in Applied Linguistic) who defend that the feedback process needs to be evaluative and formative since it sets interfaces with both students autonomy and learning improvement. Our study is based on qualitative, quantitative and interpretive researches, whose natural environment (the classroom) is a direct source of data generated in this research through field observations/note-taking as well as through the transcriptions of five English classes audio taped. This study shows the following results: the teacher still seems to accept the patterns of interaction in the classroom that correspond to the IRE process (Initiation, Response, Evaluation) in behaviorist patterns: (1) he speaks and determines the turns of speech; (2) the teacher asks more questions and directs the activities most of the time; (3) the teacher´s feedback presents the following types: questioning, modeling, repeated response, praise, depreciation, positive/negative and sarcasm feedback, whose functions are to assess students' performance based on the rightness and wrongness of their responses. Thus, this implies to state that the feedback does not seem to help students improvement in terms of acquiring knowledge because of its normative effects/roles. Therefore, it is the teacher´s role to give evaluative and formative feedback to a student so that he/she should advance in the learning of the language and in the construction of knowledge

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thermodynamic performance of a refrigeration system can be improved by reducing the compression work by a particular technique for a specific heat removal rate. This study examines the effect of small concentrations of Al2O3 (50 nm) nanoparticles dispersion in the mineral oil based lubricant on the: viscosity, thermal conductivity, and lubrication characteristics as well as the overall performance (based on the Second Law of Thermodynamics) of the refrigerating system using R134a or R600a as refrigerants. The study looked at the influences of variables: i) refrigerant charge (100, 110, 120 and 130 g), ii) rotational speed of the condenser blower (800 and 1100 RPM) and iii) nanoparticle concentration (0.1 and 0.5 g/l) on the system performance based on the Taguchi method in a matrix of L8 trials with the criterion "small irreversibility is better”. They were carried pulldown and cycling tests according to NBR 12866 and NBR 12869, respectively, to evaluate the operational parameters: on-time ratio, cycles per hour, suction and discharge pressures, oil sump temperature, evaporation and condensation temperatures, energy consumption at the set-point, total energy consumption and compressor power. In order to evaluate the nanolubricant characteristics, accelerated tests were performed in a HFRR bench. In each 60 minutes test with nanolubricants at a certain concentration (0, 0.1 and 0.5 g/l), with three replications, the sphere (diameter 6.00 ± 0.05 mm, Ra 0.05 ± 0.005 um, AISI 52100 steel, E = 210 GPa, HRC 62 ± 4) sliding on a flat plate (cast iron FC200, Ra <0.5 ± 0.005 um) in a reciprocating motion with amplitude of 1 mm, frequency 20 Hz and a normal load of 1,96 N. The friction coefficient signals were recorded by sensors coupled to the HFRR system. There was a trend commented bit in the literature: a nanolubricant viscosity reduction at the low nanoparticles concentrations. It was found the dominant trend in the literature: increased thermal conductivity with increasing nanoparticles mass fraction in the base fluid. Another fact observed is the significant thermal conductivity growth of nanolubricant with increasing temperature. The condenser fan rotational speed is the most influential parameter (46.192%) in the refrigerator performance, followed by R600a charge (38.606%). The Al2O3 nanoparticles concentration in the lubricant plays a minor influence on system performance, with 12.44%. The results of power consumption indicates that the nanoparticles addition in the lubricant (0.1 g/L), together with R600a, the refrigerator consumption is reduced of 22% with respect to R134a and POE lubricant. Only the Al2O3 nanoparticles addition in the lubricant results in a consumption reduction of about 5%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thermodynamic performance of a refrigeration system can be improved by reducing the compression work by a particular technique for a specific heat removal rate. This study examines the effect of small concentrations of Al2O3 (50 nm) nanoparticles dispersion in the mineral oil based lubricant on the: viscosity, thermal conductivity, and lubrication characteristics as well as the overall performance (based on the Second Law of Thermodynamics) of the refrigerating system using R134a or R600a as refrigerants. The study looked at the influences of variables: i) refrigerant charge (100, 110, 120 and 130 g), ii) rotational speed of the condenser blower (800 and 1100 RPM) and iii) nanoparticle concentration (0.1 and 0.5 g/l) on the system performance based on the Taguchi method in a matrix of L8 trials with the criterion "small irreversibility is better”. They were carried pulldown and cycling tests according to NBR 12866 and NBR 12869, respectively, to evaluate the operational parameters: on-time ratio, cycles per hour, suction and discharge pressures, oil sump temperature, evaporation and condensation temperatures, energy consumption at the set-point, total energy consumption and compressor power. In order to evaluate the nanolubricant characteristics, accelerated tests were performed in a HFRR bench. In each 60 minutes test with nanolubricants at a certain concentration (0, 0.1 and 0.5 g/l), with three replications, the sphere (diameter 6.00 ± 0.05 mm, Ra 0.05 ± 0.005 um, AISI 52100 steel, E = 210 GPa, HRC 62 ± 4) sliding on a flat plate (cast iron FC200, Ra <0.5 ± 0.005 um) in a reciprocating motion with amplitude of 1 mm, frequency 20 Hz and a normal load of 1,96 N. The friction coefficient signals were recorded by sensors coupled to the HFRR system. There was a trend commented bit in the literature: a nanolubricant viscosity reduction at the low nanoparticles concentrations. It was found the dominant trend in the literature: increased thermal conductivity with increasing nanoparticles mass fraction in the base fluid. Another fact observed is the significant thermal conductivity growth of nanolubricant with increasing temperature. The condenser fan rotational speed is the most influential parameter (46.192%) in the refrigerator performance, followed by R600a charge (38.606%). The Al2O3 nanoparticles concentration in the lubricant plays a minor influence on system performance, with 12.44%. The results of power consumption indicates that the nanoparticles addition in the lubricant (0.1 g/L), together with R600a, the refrigerator consumption is reduced of 22% with respect to R134a and POE lubricant. Only the Al2O3 nanoparticles addition in the lubricant results in a consumption reduction of about 5%.