2 resultados para Passive protection

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.