6 resultados para Ozônio Troposférico
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
This dissertation aims the development of an experimental device to determine quantitatively the content of benzene, toluene and xylenes (BTX) in the atmosphere. BTX are extremely volatile solvents, and therefore play an important role in atmospheric chemistry, being precursors in the tropospheric ozone formation. In this work a BTX new standard gas was produced in nitrogen for stagnant systems. The aim of this dissertation is to develop a new method, simple and cheaper, to quantify and monitor BTX in air using solid phase microextraction/ gas chromatography/mass spectrometry (SPME/CG/MS). The features of the calibration method proposed are presented in this dissertation. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fiber exposed for 10 min standard gas mixtures. It is observed that the main parameters that affect the extraction process are sampling time and concentration. The results of the BTX multicomponent system studied have shown a linear and a nonlinear range. In the non-linear range, it is remarkable the effect of competition by selective adsorption with the following affinity order p-xylene > toluene > benzene. This behavior represents a limitation of the method, however being in accordance with the literature. Furthermore, this behavior does not prevent the application of the technique out of the non-linear region to quantify the BTX contents in the atmosphere.
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
The increase in ultraviolet radiation (UV) at surface, the high incidence of non-melanoma skin cancer (NMSC) in coast of Northeast of Brazil (NEB) and reduction of total ozone were the motivation for the present study. The overall objective was to identify and understand the variability of UV or Index Ultraviolet Radiation (UV Index) in the capitals of the east coast of the NEB and adjust stochastic models to time series of UV index aiming make predictions (interpolations) and forecasts / projections (extrapolations) followed by trend analysis. The methodology consisted of applying multivariate analysis (principal component analysis and cluster analysis), Predictive Mean Matching method for filling gaps in the data, autoregressive distributed lag (ADL) and Mann-Kendal. The modeling via the ADL consisted of parameter estimation, diagnostics, residuals analysis and evaluation of the quality of the predictions and forecasts via mean squared error and Pearson correlation coefficient. The research results indicated that the annual variability of UV in the capital of Rio Grande do Norte (Natal) has a feature in the months of September and October that consisting of a stabilization / reduction of UV index because of the greater annual concentration total ozone. The increased amount of aerosol during this period contributes in lesser intensity for this event. The increased amount of aerosol during this period contributes in lesser intensity for this event. The application of cluster analysis on the east coast of the NEB showed that this event also occurs in the capitals of Paraiba (João Pessoa) and Pernambuco (Recife). Extreme events of UV in NEB were analyzed from the city of Natal and were associated with absence of cloud cover and levels below the annual average of total ozone and did not occurring in the entire region because of the uneven spatial distribution of these variables. The ADL (4, 1) model, adjusted with data of the UV index and total ozone to period 2001-2012 made a the projection / extrapolation for the next 30 years (2013-2043) indicating in end of that period an increase to the UV index of one unit (approximately), case total ozone maintain the downward trend observed in study period
Resumo:
From what was stated in the Montreal Protocol, the researchers and refrigeration industry seek substitutes for synthetic refrigerants -chlorofluorocarbons (CFCs) and HCFCs (HCFC) - that contribute to the depletion of the ozone layer. The phase-out of these substances was started using as one of the replacement alternatives the synthetic fluids based on hydro fluorocarbons (HFCs) that have zero potential depletion of the ozone layer. However, contribute to the process of global warming. HFC refrigerants are greenhouse gases and are part of the group of gases whose emissions must be reduced as the Kyoto Protocol says. The hydrocarbons (HC's), for not contribute to the depletion of the ozone layer, because they have very low global warming potential, and are found abundantly in nature, has been presented as an alternative, and therefore, are being used in new home refrigeration equipment in several countries. In Brazil, due to incipient production of domestic refrigerators using HC's, the transition refrigerants remain on the scene for some years. This dissertation deals with an experimental evaluation of the conduct of a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, temperature and pressure sensors at strategic points in the refrigeration cycle, connected to an acquisition system of computerized data, to enable the mapping and thermodynamics analysis of the device operating with R-134a or with a mixture of HC's or with R-600a. The refrigerator-test operating with the natural fluids (mixture of HC's or R-600a) had a coefficient of performance (COP) lower than the R-134a
Resumo:
Many pollutants dumped in waterways, such as dyes and pesticides, have become so ubiquitous that they represent a serious threat to human health. The electrochemical oxidation is presented as an alternative clean, efficient and economic degradation of wastewater containing organic compounds and a number of advantages of this technique is to just not make use of chemical reagents, since only electrical energy is consumed during the removal of pollutants organic. However, despite being a promising alternative, still needs some tweaking in order to obtain better efficiency in the elimination of persistent pollutants. Thus, this study sought a relationship between a recently discovered phenomenon that reflects the participation of dissolved oxygen in solution in the electrochemical oxidation process, as an anomaly, present a kinetic model that shows instantaneous current efficiency (ICE) above 100% limited by theory, manifested for some experiments with phenolic compounds with H2SO4 or HClO4 as supporting electrolyte with electrodes under anodic oxidation on boron doped diamond (BDD). Therefore it was necessary to reproduce the data ICE exposes the fault model, and thus the 2-naphthol was used as phenolic compound to be oxidised at concentrations of 9, 12 and 15 mmol L-1, and H2SO4 and HClO4 to 1 mol L-1 as a supporting electrolyte under a current density of 30 mA cm-2 in an electrochemical reactor for continuous flow disk configuration, and equipped with anodes DDB at room temperature (25 oC). Experiments were performed using N2 like as purge gas for eliminate oxygen dissolved in solution so that its influence in the system was studied. After exposure of the anomaly of the ICE model and investigation of its relationship with dissolved O2, the data could be treated, making it possible for confirmation. But not only that, the data obtained from eletranálise and spectroscopic analysis suggest the involvement of other strongly oxidizing species (O3 (ozone) and O radicals and O2 -), since the dissolved O2 can be consumed during the formation of new strong oxidizing species, not considered until now, something that needs to be investigated by more accurate methods that we may know a little more of this system. Currently the performance of the electrocatalytic process is established by a complex interaction between different parameters that can be optimized, so it is necessary to the implementation of theoretical models, which are the conceptual lens with which researchers see
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air