11 resultados para Orthodontics wire

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate factors associated to orthodontic treatment stability and patient satisfaction in the long-term. A total of 209 patients (88 class I and 121 class II) treated with straight wire fixed appliance were selected at least 5 years post treatment. Six hundred twenty seven dental casts were examined with the PAR Index at pretreatment (T1), end of treatment (T2), and at long-term follow up (T3, mean 8.5 years post treatment). At T3, a Dental Impact on Daily Living questionnaire was used to assess patient satisfaction with the dentition in the long-term. Friedman test and multiple regression analysis were used to evaluate changes among the time points and factors associated with stability and patient satisfaction. Predictive factors used to exam the occlusion were: PAR Index at T1 and T2, age at T1, the amount of time without retainer, length of Hawley retainer wear, length of follow-up, sex, extraction and third molar status. To assess patient satisfaction were considered: changes produced by the orthodontic treatment (PAR T2-T1), post treatment stability (PAR T3), age at the start of treatment (T1), length of treatment (T2-T1), gender, and extraction. Orthodontic treatment produced a significant improvement of 94.2% in the PAR Index (T2-T1), but this change was not associated with the level of satisfaction when the patient was questioned at T3. No significant change was observed between T2 and T3. However, when the sample was divided according to the level of finalization (PAR T2), it was observed that well-finished patients experienced some deterioration (P<.001), whereas the less well-finished ones showed some improvement (P<.05). Even with the deterioration, the well-finished patients still had a better PAR Index at T3 compared to the less well-finished ones (PAR T2- T3). Regression analysis showed that PAR Index at T1 and T2, age at T1, and length of retainer wear had a slight association with occlusal stability (R2 = 0.27). Patient satisfaction was significantly associated only with PAR Index at T3 (r2=0.125, P<.0001). We can conclude that, even thought orthodontic treatment is quite stable, not so well-finished treatments tend to show some improvement and well-finished ones deteriorate some in the long-term. Despite of that, well-finished patients still have better occlusal characteristics. Patient satisfaction is not related to the result of orthodontic treatment; nevertheless, there is a slight association with dentition in the long-term

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study aimed at the treatment of attapulgite for the development and characterization of composite recycled low density polyethylene - PEBD_rec embedded with natural attapulgite - ATP_NAT, sifted - ATP_PN and attapulgite treated with sulfuric acid - ATP_TR in different compositions (1, 3 and 5%) and compared with the PEBD_rec. The atapulgitas, natural, screened and treated, were characterized by X-ray diffraction (XRD), X-ray fluorescence (XRF), particle size analysis, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and determining the area specific surface (BET). The composites were characterized by thermogravimetry (TG), differential scanning calorimetry (DSC), Xray diffraction (XRD), torque rheometry, scanning electron microscopy (SEM) and traction. The composite PEBD_rec / ATP (natural, sieved and treated) were produced by mixing in the molten state in a single screw extruder matrix wire with subsequent reprocessing matrix tape. It was found that the screening of attapulgite not reduce the quantity of quartz and the acid treatment completely extracted dolomite aggregate impurities of the channels attapulgite, and increase their surface area. The addition of attapulgite in PEBD_rec acts as a catalyst, reducing the thermal stability of the polymer. The increased concentration of attapulgite, increases resistance and reduces the elongation at break and modulus of elasticity of the composite PEBD_rec / attapulgite

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this clinical study was to evaluate the effectiveness of the toothbrushing with and without fluoride and the daily fluoride rinse (NaF 0.05%) on produced white spot, in vivo. This was a clinical study, controlled, randomized and triple blind. Thirty patients were selected for orthodontics reasons from Orthodontics Specialization Course at the Brazilian Dental Association - Section of Rio Grande do Norte. In this study it was used 4 bicuspid upper and lower. They had orthodontic reason for extractions, in 35 days, at least. The sample had one hundred and twenty teeth that received orthodontic bands. The bands were fixed with polycarboxylate cement, and there was a space standardized between bands and one surface of teeth. The four bicuspid of each patients were randomized and nominated as A, B, C and D. These nominations determinated the sequence of the extractions and what was done in each tooth. All the patients had been submitted to the toothbrushing with or without fluoride for 35 days. After this period, the A tooth of each patient was extracted to serve as control. The others teeth (B, C and D) were extracted one by each week. The entire sample was analyzed through the clinical examination and by laser fluorescence (DIAGNOdent®) in three different times: before orthodontic bands, 28 days after fixed and then removed the bands and, the last one, 07 days after one of the three treatments (toothbrushing with or without fluoride, tooth paste with fluoride and mouth rinse with fluoride). At the beginning all groups (A, B, C and D) had the same conditions, no significant difference was found. The same situation was found in a clinical examination. The results of the DIAGNOdent® for the groups that used tooth paste without fluoride, with fluoride and mouth rinse with fluoride, after 28 days, there was no significant difference. Clinically, the white spot was formed in all teeth after 28 days. When it was compared the three treated groups, the group without fluoride in tooth paste had worst result than the others groups. But there was no significant association between the number of active and inactive white spots and the type of treatment that the teeth had received. The demineralization of the enamel surface, under the orthodontic bands, it happened in a few weeks. The exposition of the white spots in oral environmental resulted in an improvement, but it was not enough to return to the values from the base line, either for the toothbrushing and/or the use of fluorite mouth rinse. Mouth rinse and toothpaste with fluoride have showed to reduce the incidence of demineralization in the enamel, but none seems to be superior to another one in an in vivo study

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to characterize the thermal profile of wood fired oven used by the red ceramic industry in Parelhas, in the Seridó region/RN, aiming to propose structural interventions that can contribute to increasing productivity and product quality, optimize wood consumption and mitigate existing losses during the burning process. The study was conducted at Cerâmica Esperança in the city of Parelhas -RN, Brazil, during the period from August 2012 to September 2013. Four treatments were performed with three replicates, ie, with, a total of 12 experimental units (burnings). In the first stage 4 treatments were performed with three replicates, totaling 12 experimental units (firings). In the second stage 2 treatments were performed with three replications, totaling 6 experimental units (firings). The physical characteristics of the wood were analyzed using standard NBR 11941 and NBR 7190 for basic density and moisture, respectively. The clay was used as a reference parameter for distinguishing treatments. For both the analysis and characterization was carried out using techniques of fluorescence X (XRF) rays, X-ray diffraction (XRD) analysis, particle size analysis (FA). In the first and second stages were monitored: the time during the firing process, the amount of wood used at each firing, the number of parts enfornadas for subsequent determination of the percentages of losses, but also product quality. To characterize the thermal profile of the oven, we measured the temperature at 15 points scored in the surface charge put into the oven. Measurements were taken every 30 minutes from preheat until the end of burning, using a pyrometer laser sight sighting from preheating until the end of burning. In the second step 12 metal cylinders distributed on the oven walls, and the cylinder end walls 8 of the furnace 2 and rollers on each side walls are installed equidistant to 17 cm from the soil and the surface 30 of the wall are installed. The cylinders distributed on the front were placed 50 cm above the furnace, and the base of the oven 20 cm distant from the ground. 10 also thermocouples were installed, and five thermocouples distributed 1.77 cm above the combustion chambers, and one thermocouple on each side, and three thermocouples in front of the oven. We carried out the measurements of the temperatures every 1 hour during the burning two hours in cooling the cylinders with a pyrometer and thermocouples for dattaloger. These were fixed with depth of 30 cm from the wall. After statistical analysis it was found that: the thermal profile of the furnace surface and at different heights was heterogeneous; and the ranges of density and moisture content of wood are within recommended for use as an energy source standards. We conclude that even at low temperatures reached during firing there was a significant production of good quality products, this is due to high concentrations of iron oxide and potassium oxide found in clay, which lowers the melting point of the piece. The average burn time for each step varied 650-2100 minutes wood consumption was on average 20 m3, product quality was on average 16% of first quality, 70% second, third and 5% to 10% loss . The distance between the wire and the surface of the oven was a significant parameter for all treatments, but with different variations, meaning that the wire should not be so generic and unique form, used as a criterion for completion of the burn process. The central part of the furnace was the area that reached higher temperature, and in a unified manner, with the highest concentration of top quality products. The ideal temperature curve, which provided the highest quality of ceramic products was achieved in the central part of the furnace

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is analyzed through the concepts of tribology and mechanical contact and damage the suggestion of implementing a backup system for traction and passage of Pipeline Inspection Gauge (Pig) from the inside of pipelines. In order to verify the integrity of the pipelines, it is suggested the possibility of displacement of such equipment by pulling wires with steel wires. The physical and mechanical characteristics of this method were verified by accelerated tests in the laboratory in a tribological pair, wire versus a curve 90. It also considered the main mechanisms of wear of a sliding system with and without lubricant, in the absence and presence of contaminants. To try this, It was constructed a test bench able to reproduce a slip system, work on mode back-and-forth ("reciprocation"). It was used two kinds of wires, a galvanized steel and other stainless steel and the results achieved using the two kinds of steel cables were compared. For result comparative means, it was used steel cables with and without coating of Poly Vinyl Chloride (PVC). The wires and the curves of the products were characterized using metallographic analysis, microhardness Vickers tests, X-ray diffraction (XRD), X-Ray Refraction (XRF) and tensile tests. After the experiments were analyzed some parameters that have been measurable, it demonstrates to the impracticality of this proposed method, since the friction force and the concept of alternating request at the contact between the strands of wire and the inner curves that are part ducts caused severe wear. These types of wear are likely to cause possible failures in future products and cause fluid leaks

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To obtain a process stability and a quality weld bead it is necessary an adequate parameters set: base current and time, pulse current and pulse time, because these influence the mode of metal transfer and the weld quality in the MIG-P, sometimes requiring special sources with synergistic modes with external control for this stability. This work aims to analyze and compare the effects of pulse parameters and droplet size in arc stability in MIG-P, four packets of pulse parameters were analysed: Ip = 160 A, tp = 5.7 ms; Ip = 300 A and tp = 2 ms, Ip = 350 A, tp = 1.2 ms and Ip = 350 A, tp = 0.8 ms. Each was analyzed with three different drop diameters: drop with the same diameter of the wire electrode; droplet diameter larger drop smaller than the diameter of the wire electrode. For purposes of comparison the same was determined relation between the average current and welding speed was determined generating a constant (Im / Vs = K) for all parameters. Welding in flat plate by simple deposition for the MIG-P with a distance beak contact number (DBCP) constant was perfomed subsequently making up welding in flat plate by simple deposition with an inclination of 10 degrees to vary the DBCP, where by assessment on how the MIG-P behaved in such a situation was possible, in addition to evaluating the MIG-P with adaptive control, in order to maintain a constant arc stability. Also high speed recording synchronized with acquiring current x voltage (oscillogram) was executed for better interpretation of the transfer mechanism and better evaluation in regard to the study of the stability of the process. It is concluded that parameters 3 and 4 exhibited greater versatility; diameters drop equal to or slightly less than the diameter of the wire exhibited better stability due to their higher frequency of detachment, and the detachment of the drop base does not harm the maintenance the height of the arc

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments were performed to study the effect of surface properties of a vertical channel heated by a source of thermal radiation to induce air flow through convection. Two channels (solar chimney prototype) were built with glass plates, forming a structure of truncated pyramidal geometry. We considered two surface finishes: transparent and opaque. Each stack was mounted on a base of thermal energy absorber with a central opening for passage of air, and subjected to heating by a radiant source comprises a bank of incandescent bulbs and were performed field tests. Thermocouples were fixed on the bases and on the walls of chimneys and then connected to a data acquisition system in computer. The air flow within the chimney, the speed and temperature were measured using a hot wire anemometer. Five experiments were performed for each stack in which convective flows were recorded with values ranging from 17 m³ / h and 22 m³ / h and air flow velocities ranging from 0.38 m / s and 0.56 m / s for the laboratory tests and air velocities between 0.6 m/s and 1.1m/s and convective airflows between 650 m³/h and 1150 m³/h for the field tests. The test data were compared to those obtained by semi-empirical equations, which are valid for air flow induced into channels and simulated data from 1st Thermodynamics equation. It was found that the chimney with transparent walls induced more intense convective flows than the chimney with matte finish. Based on the results obtained can be proposed for the implementation of prototype to exhaust fumes, mists, gases, vapors, mists and dusts in industrial environments, to help promote ventilation and air renewal in built environments and for drying materials, fruits and seeds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This piece of work has investigated the alternative conceptions shown by students of secondary school, concerned to the concepts of warmth and temperature, aiming the elaboration and application of a learning strategy as of the diagnose risen from the conceptions present in students. The learning strategy was built up by a sequence of activities that involve History of Science and experiments, put in a course that had as a base the proposal of the Group of Redevelopment of Physics Teaching (GREF). We have used as the conductor wire of our research the development of thermo dynamics since the development of the first thermo machines, passing by the Industrial Revolution and the evolution of concepts of warmth and temperature. The learning strategy was applied to a group of second grade of secondary school in a public school in Mossoró (RN). By doing these activities we tried to become the concepts, which are part of thermo dynamics, more meaningful to the students. We have estimated that the application of the strategy has represented some profits to the students of the group, concerning to learning of laws and concepts of thermo dynamics (specifically the concepts of warmth and temperature), as well as what it is referred to the overcoming of its initial conceptions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of fixed orthodontics appliances interfere on sanitation, allowing periodontal diseases to appear, despite the fact patients keep on visiting the dentist every month. This research aims to determine a protocol for the mechanical control of the dental biofilm performed by the professional. A protocol that was able to maintain the periodontal health of the patients under orthodontic treatment with fixed appliances, and in order to do so, it used a non-controlled, randomized and blind clinical essay. The sample involved 40 adolescents who were under the installation of fixed orthodontics appliances and it was divided in three groups, as follows: monthly controlled group (group 1) composed of 11 patients, the quarterly controlled group (group 2) with 16 patients and the semestrial controlled group (group 3) with 13 patients. For data collection, an interview and clinical exams with probing depth measurement, quantity of keratinized mucosa, Gingival Index and the Plaque Index were used. On the initial exam all patients received brushing guidelines as well as the professional control of dental biofilm, with periodontal scaler, Robinson s brush and prophylactic paste. However, Group 1 returned every month for control procedures; Group 2 every three months and Group 3 after six months. The intervention had a six-month duration (for all the three groups), when all the exams were repeated by another examiner who did not know which group each patient was inserted in. Finally, the research concluded that despite the fact there is no statistically significant difference among the three groups, clinically the patients from the monthly group presented a better response to professional control, with less accumulation of dental biofilm and less rate of gingival inflammation. Thus, the mechanical control of the dental biofilm performed by the professional could not avoid gingival increase, characterized by the raise of probing depth measurement, neither the quantity of keratinized mucosa