2 resultados para Nodal solution
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed
Resumo:
The adhesion molecules E-cadherin and β-catenin have been studied as possible markers to distinguish carcinomas with and without metastatic potential. The objective of this research was to study the imunohistochemistry expression of the E-cadherin and β-catenin in oral squamous cell carcinoma (OSCC), aiming to contribute for the better understanding of the biological behavior of this lesion. The sample consisted of 30 cases of OSCC, being 15 of tongue and 15 of lower lip. The profile and intensity of labeling and semi quantitative analysis of the percentage of immunopositive tumoral cells in membrane for E-cadherin and β-catenin had been related with the anatomical localization of the lesion, the presence or not of nodal metastasis and the histological grade of malignancy in the invasive front area of the tumor. It was registered the presence or not of cytoplasmic and nuclear labeling of the β-catenin. The results had been submitted to the statistical analysis, being used the Mann-Whitney Test, the Fisher Test and the Spearman Correlation Coefficient (α=0, 05). The results showed that the expression in membrane for E-cadherin and β-catenin was, predominantly, the heterogeneous profile in the lower lip and tongue carcinomas, as well as in the cases with and without nodal metastasis. It was not observed significant statistical difference between expression profile and amount of immunopositive cells for E-cadherin, β-catenin and the anatomical localization of the lesion and for the presence or not of nodal metastasis. However, there was significant difference of the reduced expression of these proteins with the high score of malignancy. It was verified that the expression of the β-catenin in cytoplasm was present in 22 (73.33%) of the 30 analyzed cases, and 6 cases (20%) showed nuclear expression. The statistical analysis detected significant association between the expression of the β-catenin in the cytoplasm with the histological grade of malignancy, being this molecule more frequently present in the cytoplasm in the cases of high score of malignancy. It was concluded that the reduced immunoexpression of these proteins in membrane can be related with the lowest cellular differentiation, as well as with the pattern of invasion in nests and isolated cells, demonstrated in the cases of OSCC with high histological grade of malignancy