6 resultados para Needle bearings

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is a descriptive-exploratory research, with a quantitative approach, aiming to characterize typical occupational accident suffered by the professionals from nursery group, in the Intensive Care Units and Emergency in a hospital in Natal-RN, trying to identify the factors that contribute to those accidents; to identify some information taken by those professionals related to the accident risks; to know the procedures taken after each accident. This sample is composed by 176 professionals that are 44 nurses and 132 nursing technicians/auxiliaries, collected from March to April 2010. The results related to the personal characterization of the nursery group showed that 31 (18.61%) are between the 36-40 years of age; 148 (84.09%) females and 96 (55.68%) had finished High School. Related to the professional characterization, 53 (30.11%) are nurses, and 123 (69.88%) nursing technicians and auxiliaries; 44 (25.00%) are working as nurses, and 132 (75.00%) as nursing technicians and auxiliaries; 45 (25.56%) are working in the nursery area between 15 to 20 years and 11 months; 53 (30.11%) are in this institution between 10 to 14 years and 11 months; 79 (44.88%) work in the ICU; 55 (31.25%) are working in this area from 1 to 4 years and 11 months; 110 (62.50%) like to work in this area; 161 (91.47%) work 30 to 40 hours per week; 90 (51,13%) have another employment. Related to knowledge about typical occupational accident, 167 (94.88%) said they know about it; 96 (54.54%) know the accident rules; 103 (58.52%) think it is important to talk about this subject in the nursery courses; 92 (52.27%) said this subject is important to be discussed in the work and 372 (87.73%) think education is necessary to reduce accident. Related to the data about accidents, 104 (59.09%) have suffered typical occupational accident, among them 69 (39.20%) have suffered it once; 47 (36.19%) did not register any accident; 60 (57.69%) were caring some patient during the accident; 47 (45.19%) of them occurred in the ICU; 50 (48.07%) professionals were working during the night period; 69 (66.34%) have suffered perforation; 86 (82.69%) had upper limbs affected; 64 (61.53%) were affected by needle; about the reason of the accident, 89 (60.54%) said it occurred due to carelessness. Related to the accident evolution, 88 (85.57%) did not need to remain off work after accident; 13 (81.25%) remained off work during 15 days; 87 (83.65%) had no sequelae and for 101 (97.11%) it was not necessary rehabilitation. We conclude that typical occupational accident can occur with young workers who admit a knowledge about the subject, however they do almost nothing to prevent it. We believe this research has contributed to the characterization of this kind of accident suffered by the nursery group of a public hospital in Natal, and it can stimulate the creation and reformulation of personal protection against typical occupational accident suffered by nursery professionals

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breast cancer, despite being one of the leading causes of death among women worldwide is a disease that can be cured if diagnosed early. One of the main techniques used in the detection of breast cancer is the Fine Needle Aspirate FNA (aspiration puncture by thin needle) which, depending on the clinical case, requires the analysis of several medical specialists for the diagnosis development. However, such diagnosis and second opinions have been hampered by geographical dispersion of physicians and/or the difficulty in reconciling time to undertake work together. Within this reality, this PhD thesis uses computational intelligence in medical decision-making support for remote diagnosis. For that purpose, it presents a fuzzy method to assist the diagnosis of breast cancer, able to process and sort data extracted from breast tissue obtained by FNA. This method is integrated into a virtual environment for collaborative remote diagnosis, whose model was developed providing for the incorporation of prerequisite Modules for Pre Diagnosis to support medical decision. On the fuzzy Method Development, the process of knowledge acquisition was carried out by extraction and analysis of numerical data in gold standard data base and by interviews and discussions with medical experts. The method has been tested and validated with real cases and, according to the sensitivity and specificity achieved (correct diagnosis of tumors, malignant and benign respectively), the results obtained were satisfactory, considering the opinions of doctors and the quality standards for diagnosis of breast cancer and comparing them with other studies involving breast cancer diagnosis by FNA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical Motors transform electrical energy into mechanic energy in a relatively easy way. In some specific applications, there is a need for electrical motors to function with noncontaminated fluids, in high speed systems, under inhospitable conditions, or yet, in local of difficult access and considerable depth. In these cases, the motors with mechanical bearings are not adequate as their wear give rise to maintenance. A possible solution for these problems stems from two different alternatives: motors with magnetic bearings, that increase the length of the machine (not convenient), and the bearingless motors that aggregate compactness. Induction motors have been used more and more in research, as they confer more robustness to bearingless motors compared to other types of machines building with others motors. The research that has already been carried out with bearingless induction motors utilized prototypes that had their structures of stator/rotor modified, that differ most of the times from the conventional induction motors. The goal of this work is to study the viability of the use of conventional induction Motors for the beringless motors applications, pointing out the types of Motors of this category that can be more useful. The study uses the Finite Elements Method (FEM). As a means of validation, a conventional induction motor with squirrel-cage rotor was successfully used for the beringless motor application of the divided winding type, confirming the proposed thesis. The controlling system was implemented in a Digital Signal Processor (DSP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Present work proposed to map and features the wear mechanisms of structural polymers of engineering derived of the sliding contact with a metallic cylindrical spindle submitted to eccentricity due to fluctuations in it is mass and geometric centers. For this it was projected and makes an experimental apparatus from balancing machine where the cylindrical counterbody was supported in two bearings and the polymeric coupon was situated in a holder with freedom of displacement along counterbody. Thus, the experimental tests were standardized using two position of the two bearings (Fixed or Free) and seven different positions along the counterbody, that permit print different conditions to the stiffness from system. Others parameters as applied normal load, sliding velocity and distance were fixed. In this investigation it was used as coupon two structural polymers of wide quotidian use, PTFE (polytetrafluroethylene) and PEEK (poly-ether-ether-ketone) and the AISI 4140 alloy steel as counterbody. Polymeric materials were characterized by thermal analysis (thermogravimetric, differential scanning calorimetry and dynamic-mechanical), hardness and rays-X diffractometry. While the metallic material was submitted at hardness, mechanical resistance tests and metallographic analysis. During the tribological tests were recorded the heating response with thermometers, yonder overall velocity vibration (VGV) and the acceleration using accelerometers. After tests the wear surface of the coupons were analyzed using a Scanning Electronic Microscopy (SEM) to morphological analysis and spectroscopy EDS to microanalysis. Moreover the roughness of the counterbody was characterized before and after the tribological tests. It was observed that the tribological response of the polymers were different in function of their distinct molecular structure. It were identified the predominant wear mechanisms in each polymer. The VGV of the PTFE was smaller than PEEK, in the condition of minimum stiffness, in function of the higher loss coefficient of that polymer. Wear rate of the PTFE was more of a magnitude order higher than PEEK. With the results was possible developed a correlation between the wear rate and parameter (E/ρ)1/2 (Young modulus, E, density, ρ), proportional at longitudinal elastic wave velocity in the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of salting and drying in the sun is used to preserve meat since the beginning of civilization. There is evidence that this preservation technique has arisen in Egypt, between 4,000 and 5,000 years ago. In our country, according to literature, was the first industrial product that gave the appearance of beef jerky, beef being produced, where about 70% to 75% of the muscle is composed of water, where it will be around 45% as a final product, according to the law in his article RIISPOA No. 432 provides that the jerky should contain no more than this amount of moisture in the muscular portion, or more than 15% of total ash with tolerance of up to 5% variation . Besides this parameter, proteins, lipids, ash, and minerals were analyzed in samples before and after the manufacturing process to know the content of these nutrients. Since these are considered important in product quality, thus the concentration in these samples, respectively, in the flesh Front (CD and CHD) before and after the manufacturing process for humidity were respectively 75.28% and 47.38% , the protein was 14.17 and 22.20 g / 100 g sample, 6.360 and 4.251 of lipids g/100g of the sample, and the ashes 0.974 9.144 g/100g sample, minerals like calcium and 4.074 30 , 06 ppm, sódio0, 055 and 5.401 g / L, sodium chloride, 0.139 and 13.74 g / L, potassium 237.5 and 166.8 ppm, 1.721 and 3.295 ppm iron, 0.143 and 0.135 ppm phosphorus, zinc and 4.690 6.905 ppm; magnésio14, 63 e13, 75 ppm manganese .017 e0, 007ppm, copper 0.057 and 0.039 ppm in the case of needle-type meat (CPA and CHPA), 68.04% and 44.17%, protein 13 , 72, and 24.42 g/100g of sample, 1.137 in the ash and 12.68 g / 100g of sample, and the minerals calcium 17.11 and 12.89 ppm; sódio0, 123 and 4.871 g / L, sodium chloride 0.312 and 12.39 g / L, potassium 305.3 and 182.1 ppm; ferro1, 817 and 1.513 ppm, 0.273 and 0.139 ppm phosphorus, zinc 6.305 and 4.783 ppm, 27.95 and 15.85 ppm magnesium, manganese and 0.025 0.011 ppm, 0.057 and 0.143 ppm copper and chromium 0.014 and 0.068 ppm