17 resultados para NI-CU ALLOYS

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Nb-Cu pseudoalloys present themselves as potential substitutes for the alloys from a well known system and already commercially applied, as the W-Cu alloys, used in applications such as heat sinks, electrical contacts and coils for the generation of high magnetic fields. Because it is an immiscible system, where there is mutual insolubility and low wettability of the liquid Cu on the Nb surface, the processing route used in this work was the Powder Metallurgy. Two Nb alloys were used, with additions of 10% and 20% in weight of Cu, and times of 20, 30 and 40 hours for the high energy milling of the starting powders. The milling evolution of the powders is presented through the characterization techniques, such as the LASER diffraction for particle size, XRD, SEM, EDS, DSC, dilatometry, TEM and chemical analysis. After the milling, portions of the loads were submitted to the annealing heat treatment. The process used for the samples consolidation was the hot pressing, which has been applied both on some milled powders samples, as on the annealed powders. Subsequent heat treatments were performed in the samples at temperatures of 1000ºC (solid phase) and 1100ºC (in the Cu liquid phase). All sets of consolidated samples, and also the two sets of the heat treated, were analyzed by XRD, SEM, EDS, density and Vickers microhardness. Moreover, other Nb powder samples with 10% and 20% in weight of Cu obtained by simple mechanical mixing, were consolidated, thermally treated and characterized with the same techniques applied to the others, and the results were compared among themselves. Despite the difficulty of consolidation and densification of the two pseudoalloys of the Nb-Cu system of this study, on the route that passes through the HEM, samples were obtained with densities around 90% of the theoretical density. And, on the processing route of which were only mixed, the values reached up to 97%. Therefore, in this work are also emphasized the processes that made possible these results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Brazil is the third largest producer of cashew nuts in the world. Despite the social and economic importance of the cashew nut, its production is still carried out artisanally. One of the main problems encountered in the cashew production chain are the conditions under which the roasting of the nut occurs to obtain the kernel from the shell. In the present study was conducted a biomonitoring of the genotoxic and cytotoxicity effects associated with the elements from the cashew nut roasting in João Câmara - RN, semi-arid region of Brazil. To assess the genotoxic was used the bioassay of micronucleus (MN) in Tradescantia pallida. In addition, it was performed a comparative between the Tradescantia pallida and KU-20 and other biomarkers of DNA damage, such as the nucleoplasmic bridges (NBP) and nuclear fragments (NF) were quantified. The levels of particulate matter (PM1.0, PM2.5, PM10) and black carbon (BC) were also measured and the inorganic chemical composition of the PM2.5 collected was determined using X-ray fluorescence spectrometry analysis and the assessment of the cytotoxicity by MTT assay and exclusion method by trypan blue. . For this purpose, were chosen: the Amarelão community where the roasting occurs and the Santa Luzia farm an area without influence of this process. The mean value of PM2.5 (Jan 2124.2 μg/m3; May 1022.2 μg/m3; Sep 1291.9 μg/m3) and BC (Jan 363.6 μg/m3; May 70.0 μg/m3; Sep 69.4 μg/m3) as well as the concentration of the elements Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br and Pb obtained at Amarelão was significantly higher than at Santa Luzia farm. The genotoxicity tests with T. pallida indicated a significant increase in the number of MN, NBP and NF and it was found a negative correlation between the frequency of these biomarkers and the rainfall. The concentrations of 200 μg/mL and 400 μg/mL of PM2.5 were cytotoxic to MRC-5 cells. All together, the results indicated genotoxicity and citotoxicity for the community of Amarelão, and the high rates of PM2.5 considered a potential contributor to this effect, mainly by the high presence of transition metals, especially Fe, Ni, Cu, Cr and Zn, these elements have the potential to cause DNA damage. Other nuclear alterations, such as the NPBs and NFs may be used as effective biomarkers of DNA damage in tetrads of Tradescantia pallida. The results of this study enabled the identification of a serious occupational problem. Accordingly, preventative measures and better practices should be adopted to improve both the activity and the quality of life of the population. These measures are of fundamental importance for the sustainable development of this activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The metalceramic crowns are usually used in dentistry because they provide a resistant structure due to its metallic base and its aesthetics from the porcelain that recovers this structure. To manufacture these crowns, a series of stages should be accomplished in the prosthetic laboratories, and many variables can influence its success. Changes in these variables cause alterations in the metallic alloy and in the porcelain, so, as consequence, in the adhesion between them. The composition of the metal alloy can be modified by recasting alloys, a common practice in some prosthetic laboratories. The aim of this paper is to make a systematic study investigating metalceramic crowns as well as analyzing the effect of recasting Ni-Cr alloys. Another variable which can influence the mechanism of metalceramic union is the temperature used in firing porcelain procedure. Each porcelain has to be fired in a fixed temperature which is determined by the manufacturer and its change can cause serious damages. This research simulate situations that may occur on laboratory procedures and observe their consequences in the quality of the metalceramic union. A scanning eletron microscopy and an optic microscopy were accomplish to analyse the metal-ceramic interface. No differences have been found when remelting alloys were used. The microhardness were similar in Ni-Cr alloys casted once, twice and three times. A wettability test was accomplished using a software developed at the Laboratório de Processamento de Materiais por Plasma, on the Universidade Federal do Rio Grande do Norte. No differences were found in the contact angle between the solid surface (metallic substratum) and the tangencial plane to the liquid surface (opaque). To analyse if the temperature of porcelain firing procedure could influence the contact area between metal and porcelain, a variation in its final temperature was achieve from 980° to 955°C. Once more, no differences have been found

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The groundwater represents the most important freshwater supply of planet. Dailly, in all world a great amount of toxic and genotoxic material reaches the aquatic systems, mainly the aquifers. The Barreiras aquifer through of five water wells is responsible for the supplying of Universidade Federal do Rio Grande do Norte (UFRN). All water wells are polluted with nitrate and some heavy metals, two of them were disabled. The genotoxicity of groundwater samples from Barreiras Aquifer in UFRN was assessed using the Allium cepa test, the Ames test and the Salmonella typhymurium microsuspension test (Kado test). For the Allium cepa test the influence of the groundwater samples collected on macroscopic (root length, colour and form) and microscopic (root tip mitotic index, chromosome aberrations and micronucleus) parameters was examined. All water samples caused a significant increase of the chromosome and mitotic aberration frequency and reduction on the rooth growth compared to negative control. Bridges and chromosome stickness were the most frequent kind of aberration in dividing cells. Furthermore, breaks were also observed. No significant increase in the number of micronuclei was found in relation to the negative controls. For Ames test were used the Salmonella typhymurium strains TA98 and TA100 without metabolic activation, applying the direct method. Prior to the Kado test, organic fractions from the water samples were obtained through XAD resin concentration. The mutagenicity organic extracts were evaluated by Kado test using TA98 and TA100 strains, in the absence and presence of S9 mix (metabolic activation). The concentrations of seven heavy metal ions were measured in water samples, but only Ni, Cu and Cr levels exceeded the permissible maximum concentration for the natural reservoirs. The results obtained for mutagenic activity using the Ames test were negative in all raw water samples analyzed. Positive results in XAD4 extracts of water samples were obtained for TA98 in the presence of S9 mix for two stations. Concentrations of heavy metals and nitrate can be correlated with the toxicity and genotoxicity of water analyzed. The mutagenic effect detected with TA98 strain suggested that organic compounds (after metabolization) are involved with the mutagenicity detected in the samples analyzed. The data set obtained in this work indicated the presence of at least two classes of mutagens: organic and inorganic compounds

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although there are many studies on urban dust contamination by heavy metals in developed countries, little attention has been paid to this type of study in developing countries, including Brazil. Therefore, a series of investigations were performed to provide signatures of heavy metals in urban dust and assess the potential sources in the city of Natal - RN-Brazil. The fraction of these sediments was studied to pass through a sieve of 63 micrometers. For the study analyzed two groups of samples, one collected in September 2009 at the end of the rainy season (9 samples) and one collected in January 2010 in the dry season (21 samples). So in all, thirty sediment samples were collected from the street. Then, in Fluorescence Spectrometry X-rays were determined major elements SiO2, Na2O, K2O, Al2O3, MgO, P2O5, Fe2O3, MnO, TiO2 and CaO, and trace Rb, Cr, Ni, Cu, Zn, Sr and Pb by an ICPOES was determined Zn, V, Na, K, Ni, Mn, Mg, P, Fe, Cr, Cu, Pb, Ba, Ca and Al from leaching HCl 0.5 mol L-1 . The results of the concentrations of elements show that the greater presence of these occurs in the dry season, except for Si which is higher in the rainy season. Analyses by geoaccumulation Index (IGEO) Enrichment Factor (EF), Contamination Factor (CF), analysis correlation and Hierarchical Cluster, confirm that Zn, Cu and Pb is anthropogenic character. Zinc may be derived from various sources related to motor vehicles or the road signs and street grids. The elements Na, K, Mg and Ca may be related to droplets suspended in air containing cations and anions present in seawater (salty), common in Christmas throughout the year, brought by winds SE-NW. The elements Na, Mg, Ca and K are the most abundant in seawater and were analyzed in this study. This indicates that the source of these additional elements detected by analyzing the contamination factor may be the very sea. Moreover, Ni, Fe, Cr and Ba can be either as a source of anthropogenic geogênica. The source of Ca is different, because it comes in lime and paint (painting guides of buildings and streets) in construction materials, but may also be present in sediments in the fragments of shells or carbonate bioclasts common in the coastal area

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to assess ambient air quality in a urban area of Natal, capital of Rio Grande do Norte (latitude 5º49'29 '' S and longitude 35º13'34'' W), aiming to determine the metals concentration in particulate matter (PM10 and PM2,5) of atmospheric air in the urban area o the Natal city. The sampling period for the study consisted of data acquisition from January to December 2012. Samples were collected on glass fiber filters by means of two large volumes samplers, one for PM2,5 (AGV PM 2,5) and another for PM10 (PM10 AGV). Monthly averages ranged from 8.92 to 19.80 g.m-3 , where the annual average was 16,21 g.m-3 for PM10 and PM2,5 monthly averages ranged from 2,84 to 7,89 g.m -3 , with an annual average of 5,61 g.m-3 . The results of PM2,5 and PM10 concentrations were related meteorological variables and for information on the effects of these variables on the concentration of PM, an exploratory analysis of the data using Principal Component Analysis (PCA) was performed. The results of the PCA showed that with increasing barometric pressure, the direction of the winds, the rainfall and relative humidity decreases the concentration of PM and the variable weekday little influence compared the meteorological variables. Filters containing particulate matter were selected in six days and subjected to microwave digestion. After digestion samples were analyzed by with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The concentrations for heavy metals Vanadium, Chromium, Manganese, Nickel, Copper, Arsenic and lead were determined. The highest concentrations of metals were for Pb and Cu, whose average PM10 values were, respectively, 5,34 and 2,34 ng.m-3 and PM2,5 4,68 and 2,95 ng.m-3 . Concentrations for metals V, Cr, Mn, Ni, and Cd were respectively 0,13, 0,39, 0,48, 0,45 and 0,03 ng.m-3 for PM10 fraction and PM2,5 fraction, 0,05, 0,10, 0,10, 0,34 and 0,01 ng.m-3. The concentration for As was null for the two fractions

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Brazil is the third largest producer of cashew nuts in the world. Despite the social and economic importance of the cashew nut, its production is still carried out artisanally. One of the main problems encountered in the cashew production chain are the conditions under which the roasting of the nut occurs to obtain the kernel from the shell. In the present study was conducted a biomonitoring of the genotoxic and cytotoxicity effects associated with the elements from the cashew nut roasting in João Câmara - RN, semi-arid region of Brazil. To assess the genotoxic was used the bioassay of micronucleus (MN) in Tradescantia pallida. In addition, it was performed a comparative between the Tradescantia pallida and KU-20 and other biomarkers of DNA damage, such as the nucleoplasmic bridges (NBP) and nuclear fragments (NF) were quantified. The levels of particulate matter (PM1.0, PM2.5, PM10) and black carbon (BC) were also measured and the inorganic chemical composition of the PM2.5 collected was determined using X-ray fluorescence spectrometry analysis and the assessment of the cytotoxicity by MTT assay and exclusion method by trypan blue. . For this purpose, were chosen: the Amarelão community where the roasting occurs and the Santa Luzia farm an area without influence of this process. The mean value of PM2.5 (Jan 2124.2 μg/m3; May 1022.2 μg/m3; Sep 1291.9 μg/m3) and BC (Jan 363.6 μg/m3; May 70.0 μg/m3; Sep 69.4 μg/m3) as well as the concentration of the elements Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br and Pb obtained at Amarelão was significantly higher than at Santa Luzia farm. The genotoxicity tests with T. pallida indicated a significant increase in the number of MN, NBP and NF and it was found a negative correlation between the frequency of these biomarkers and the rainfall. The concentrations of 200 μg/mL and 400 μg/mL of PM2.5 were cytotoxic to MRC-5 cells. All together, the results indicated genotoxicity and citotoxicity for the community of Amarelão, and the high rates of PM2.5 considered a potential contributor to this effect, mainly by the high presence of transition metals, especially Fe, Ni, Cu, Cr and Zn, these elements have the potential to cause DNA damage. Other nuclear alterations, such as the NPBs and NFs may be used as effective biomarkers of DNA damage in tetrads of Tradescantia pallida. The results of this study enabled the identification of a serious occupational problem. Accordingly, preventative measures and better practices should be adopted to improve both the activity and the quality of life of the population. These measures are of fundamental importance for the sustainable development of this activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The metalceramic crowns are usually used in dentistry because they provide a resistant structure due to its metallic base and its aesthetics from the porcelain that recovers this structure. To manufacture these crowns, a series of stages should be accomplished in the prosthetic laboratories, and many variables can influence its success. Changes in these variables cause alterations in the metallic alloy and in the porcelain, so, as consequence, in the adhesion between them. The composition of the metal alloy can be modified by recasting alloys, a common practice in some prosthetic laboratories. The aim of this paper is to make a systematic study investigating metalceramic crowns as well as analyzing the effect of recasting Ni-Cr alloys. Another variable which can influence the mechanism of metalceramic union is the temperature used in firing porcelain procedure. Each porcelain has to be fired in a fixed temperature which is determined by the manufacturer and its change can cause serious damages. This research simulate situations that may occur on laboratory procedures and observe their consequences in the quality of the metalceramic union. A scanning eletron microscopy and an optic microscopy were accomplish to analyse the metal-ceramic interface. No differences have been found when remelting alloys were used. The microhardness were similar in Ni-Cr alloys casted once, twice and three times. A wettability test was accomplished using a software developed at the Laboratório de Processamento de Materiais por Plasma, on the Universidade Federal do Rio Grande do Norte. No differences were found in the contact angle between the solid surface (metallic substratum) and the tangencial plane to the liquid surface (opaque). To analyse if the temperature of porcelain firing procedure could influence the contact area between metal and porcelain, a variation in its final temperature was achieve from 980° to 955°C. Once more, no differences have been found

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Heavy metals can cause problems of human poisoning by ingestion of contaminated food, and the environment, a negative impact on the aquatic fauna and flora. And for the presence of these metals have been used for aquatic animals biomonitoramento environment. This research was done in order to assess the environmental impact of industrial and domestic sewage dumped in estuaries potiguares, from measures of heavy metals in mullet. The methods used for these determinations are those in the literature for analysis of food and water. Collections were 20 samples of mullet in several municipality of the state of Rio Grande do Norte, from the estuaries potiguares. Were analyzed the content of humidity, ash and heavy metals. The data were subjected to two methods of exploratory analysis: analysis of the main components (PCA), which provided a multivariate interpretation, showing that the samples are grouped according to similarities in the levels of metals and analysis of hierarchical groupings (HCA), producing similar results. These tests have proved useful for the treatment of the data producing information that would hardly viewed directly in the matrix of data. The analysis of the results shows the high levels of metallic species in samples Mugil brasiliensis collected in Estuaries /Potengi, Piranhas/Açu, Guaraíra / Papeba / Arês and Curimataú

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The determination and monitoring of metallic contaminants in water is a task that must be continuous, leading to the importance of the development, modification and optimization of analytical methodologies capab le of determining the various metal contaminants in natural environments, because, in many cases, the ava ilable instrumentation does not provide enough sensibility for the determination of trace values . In this study, a method of extraction and pre- concentration using a microemulsion system with in the Winsor II equilibrium was tested and optimized for the determination of Co, Cd, P b, Tl, Cu and Ni through the technique of high- resolution atomic absorption spectrometry using a continuum source (HR-CS AAS). The optimization of the temperature program for the graphite furnace (HR-CS AAS GF) was performed through the pyrolysis and atomization curves for the analytes Cd, Pb, Co and Tl with and without the use of different chemical modifiers. Cu and Ni we re analyzed by flame atomization (HR-CS F AAS) after pre-concentr ation, having the sample introduction system optimized for the realization of discrete sampling. Salinity and pH levels were also analyzed as influencing factors in the efficiency of the extraction. As final numbers, 6 g L -1 of Na (as NaCl) and 1% of HNO 3 (v/v) were defined. For the determination of the optimum extraction point, a centroid-simplex statistical plan was a pplied, having chosen as the optimum points of extraction for all of the analytes, the follo wing proportions: 70% aqueous phase, 10% oil phase and 20% co-surfactant/surfactant (C/S = 4). After extraction, the metals were determined and the merit figures obtained for the proposed method were: LOD 0,09, 0,01, 0,06, 0,05, 0,6 and 1,5 μg L -1 for Pb, Cd, Tl, Co, Cu and Ni, re spectively. Line ar ranges of ,1- 2,0 μg L -1 for Pb, 0,01-2,0 μg L -1 for Cd, 1,0 - 20 μg L -1 for Tl, 0,1-5,0 μg L -1 for Co, 2-200 μg L -1 and for Cu e Ni 5-200 μg L -1 were obtained. The enrichment factors obtained ranged between 6 and 19. Recovery testing with the certified sample show ed recovery values (n = 3, certified values) after extraction of 105 and 101, 100 and 104% for Pb, Cd, Cu and Ni respectively. Samples of sweet waters of lake Jiqui, saline water from Potengi river and water produced from the oil industry (PETROBRAS) were spiked and the recovery (n = 3) for the analytes were between 80 and 112% confirming th at the proposed method can be used in the extraction. The proposed method enabled the sepa ration of metals from complex matrices, and with good pre-concentration factor, consistent with the MPV (allowed limits) compared to CONAMA Resolution No. 357/2005 which regulat es the quality of fresh surface water, brackish and saline water in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metal/ceramic interfaces using zirconia have dominated the industrial applications in the last decade, due to the high mechanical strength and fracture toughness of zirconia, especially at temperatures below 300 ºC. Also noteworthy is the good ionic conductivity in high temperatures of this component. In this work joining between ZrO2 Y-TZP and ZrO2 Mg-PSZ with austenitic stainless steel was studied. These joints were brazed at high-vacuum after mechanical metallization with Ti using filler alloys composed by Ag-Cu and Ag-Cu-Ni. The influence of the metallization, and the affinity between the different groups (ceramic / filler alloys) was evaluated, in order to achieve strong metal/ceramic joints. Evaluation of joints and interfaces, also the characterization of base materials was implemented using various techniques, such as: x-ray diffraction, leak test, three-point flexural test and scanning electron microscopy with chemical analysis. The microstructural analysis revealed physical and chemical bonds in the metal/ceramic interfaces, providing superior leak proof joints and stress cracking, in order to a good joint in all brazed samples. Precipitation zones and reaction layers with eutetic characteristics were observed between the steel and the filler metal