The purpose of the study was to compare hemiparetic gait overground and on the treadmill. Seventeen chronic stroke patients were included in the study. They walked overground and on a treadmill level at the same speed. The Qualisys Medical AB motion analysis system was used to quantify the joint kinematic of the paretic lower limb and the spatio-temporal parameters on the two conditions: overground walking and treadmill walking on three samples of 5-minutes. During the first sample, the subjects walked on the treadmill with greater cadence, shorter stride length, shorter step time on the lower paretic limb, greater range of motion in the hip and knee, greater knee flexion at the initial contact, more extension of the knee and lower dorsiflexion of the ankle at the stance phase. It is important to emphasize that the maximal knee flexion and ankle dorsiflexion just occurred later on the treadmill. Comparisons between each walking sample on the treadmill hadn t revealed any changes on the gait parameters over time. Nonetheless, when analyzing the third walking sample on the treadmill and overground, some variables showed equivalence as such as the total range of motion of the hip, the knee angle at the initial contact and its maximal extension at the stance phase. In summary, walking on a treadmill, even thought having some influence on the familiarization process, haven t demonstrated a complete change in its characteristics of hemiparetic chronic patients

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Treadmill training with partial body weight support (BWS) has shown many benefits for patients after a stroke. But their findings are not well known when combined with biofeedback. OBJETIVE: The purpose of this study was to evaluate the immediate effects of biofeedback, visual and auditory, combined with treadmill training with BWS on on walking functions of hemiplegic subjects. METHODS: We conducted a clinical trial, randomized controlled trial with 30 subjects in the chronic stage of stroke, underwent treadmill training with BWS (control), combined with visual biofeedback, given by the monitor of the treadmill through the symbolic appearance of feet as the subject gave the step; or auditory biofeedback, using a metronome with a frequency of 115% of the cadence of the individual. The subjects were evaluated by kinematics, and the data obtained by the Motion Analysis System Qualisys. To assess differences between groups and within each group after training was applied to ANOVA 3 x 2 repeated measures. RESULTS: There were no statistical differences between groups in any variable spatio-temporal and angular motion, but within each group there was an increase in walking speed and stride length after the training. The group of visual biofeedback increased the stance period and reduced the swing period and reason of symmetry, and the group auditory biofeedback reduced the double stance period. The range of motion of the knee and ankle and the plantar flexion increased in the visual biofeedback group. CONCLUSION: There are no differences between the immediate effects of gait training on a treadmill with BWS performed with and without visual or auditory biofeedback. However, the visual biofeedback can promote changes in a larger number of variables spatiotemporal and angular gait

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The intrinsic gait disorders in individuals with Parkinson's disease (PD) are one of the most disabling motor symptoms. Among the therapeutic approaches used in attempts to improve the motor function, especially the gait pattern of individuals, stands out the treadmill gait training associated with the addition of load. However, there are few findings that elucidate the benefits arising from such practice. Objective: To assess the effects of adding load on the treadmill gait training in individuals with PD. Material and Methods: A controlled, randomized and blinded clinical trial, was performed with a sample of 27 individuals (18 men and 9 women) with PD, randomly assigned to three experimental conditions, namely: treadmill gait training (n=9), treadmill gait training associated with addition of 5% load (n=9) and treadmill gait training associated with addition of 10% load (n=9). All volunteers were assessed, during phase on of Parkinson's medication, regarding to demographic, clinical and anthropometric (identification form) data, level of disability (Hoehn and Yahr Modified Scale), cognitive function (Mini Mental State Examination), clinical functional - in those areas activity of daily living and motor examination (Unified Parkinson's Disease Rating Scale - UPDRS) and gait cinematic analysis was performed through Qualisys Motion Capture System®. The intervention protocol consisted of gait training in a period of 4 consecutive weeks, with three weekly sessions, lasting 30 minutes each. The post-intervention assessment occurred the next day after the last training session, which was performed cinematic analysis of gait and the UPDRS. Data analysis was performed using the software Statistical Package for Social Sciences® (SPSS) 17.0. Results: The age of volunteers ranged from 41 to 75 years old (62,26 ± 9,07) and the time of clinical diagnosis of PD between 2 to 9 years (4,56 ± 2,42). There was a reduction regarding the score from motor exam domain (p=0,005), only when training with the addition of a 5% load. As for the space-time variables there was no significant difference between groups (p>0,120); however, the training with addition of 5% load presented the following changes: increase in stride length (p=0,028), in step length (p=0,006), in time balance of the most affected member (p=0,006) and reduction in support time of the referred member (p=0,007). Regarding angular variables significant differences between groups submitted to treadmill gait training without addition load and with 5% of load were observed in angle of the ankle at initial contact (p=0,019), in plantar flexion at toe-off (p=0,003) and in the maximum dorsiflexion in swing (p=0,005). While within groups, there was a reduction in amplitude of motion of the ankle (p=0,048), the only workout on the treadmill. Conclusion: The treadmill gait training with addition of 5% load proved to be a better experimental condition than the others because it provided greater gains in a number of variables (space-time and angular gait) and in the motion function, becoming a therapy capable of effectively improving the progress of individuals with PD

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The gait automaticity loss difficults realization of concurrent activities - Dual Task (DT). In these situations, individuals with Parkinson`s disease (PD) show a significant reduction in gait velocity and stride length, as strides variability and asymmetry increased, factors predisposing to falls. However, recent studies have shown that training involving DT may cause subsequent improvements in gait variables with DT in individuals with PD. The treadmill use was adopted by this study, by promoting greater regularity in step and enhance training. Objective:To investigate immediate effects of gait training associated with cognitive tasks on gait in individuals with PD. Methods: Twenty-two volunteers were randomly divided into two groups: control group (n = 11), who performed gait training on a treadmill for 20 minutes, and the experimental group (n = 11), who performed treadmill gait training for 20 minutes associated with cognitive tasks of verbal fluency, memory, and spatial planning. Participants were evaluated in phase on of antiparkinsonian medication as the demographic, clinical and anthropometric (identification form), cognitive status (Montreal Cognitive Assessment - MoCA), executive function (Frontal Assessment Battery), level of physical disability (Hoehn and Yahr Modified), motor and functional status (Unified Rating Scale for Parkinson`s Disease - UPDRS), and kinematics (Qualisys Motion Capture System). Results: There were not differences between groups, but both showed improvement after the intervention. The control group had an increase in velocity (p = 0.008), stride length (p = 0.04), step length (p = 0.02) and decreased double support time(p = 0.03). The experimental group showed an increase in speed (p = 0.002), stride length (p = 0.008), step length (p = 0.02) and cadence (p = 0.01), as well as a decrease in the width stride (p = 0.001) and total support time (p = 0.02). As the angular variables, the experimental group had a significant increase in the initial contact angle of ankle (p = 0.01). Conclusion: The gait training combined with cognitive activities didn`t provide significant improvements in gait variables with DT, but this study was the first to demonstrate that gait training on treadmill as simple task minimized the negative interference of DT in PD

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The motion capture is a main tool for quantitative motion analyses. Since the XIX century, several motion caption systems have been developed for biomechanics study, animations, games and movies. The biomechanics and kinesiology involves and depends on knowledge from distinct fields, the engineering and health sciences. A precise human motion analysis requires knowledge from both fields. It is necessary then the use of didactics tools and methods for research and teaching for learning aid. The devices for analysis and motion capture currently that are found on the market and on educational institutes presents difficulties for didactical practice, which are the difficulty of transportation, high cost and limited freedom for the user towards the data acquisition. Therefore, the motion analysis is qualitatively performed or is quantitatively performed in highly complex laboratories. Based is these problems, this work presents the development of a motion capture system for didactic use hence a cheap, light, portable and easily used device with a free software. This design includes the selection of the device, the software development for that and tests. The developed system uses the device Kinect, from Microsoft, for its low cost, low weight, portability and easy use, and delivery tree-dimensional data with only one peripheral device. The proposed programs use the hardware to make motion captures, store them, reproduce them, process the motion data and graphically presents the data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increase in the efficiency of photo-voltaic systems has been the object of various studies the past few years. One possible way to increase the power extracted by a photovoltaic panel is the solar tracking, performing its movement in order to follow the sun’s path. One way to activate the tracking system is using an electric induction motor, which should have sufficient torque and low speed, ensuring tracking accuracy. With the use of voltage source inverters and logic devices that generate the appropriate switching is possible to obtain the torque and speed required for the system to operate. This paper proposes the implementation of a angular position sensor and a driver to be applied in solar tracker built at a Power Electronics and Renewable Energies Laboratory, located in UFRN. The speed variation of the motor is performed via a voltage source inverter whose PWM command to actuate their keys will be implemented in an FPGA (Field Programmable Gate Array) device and a TM4C microcontroller. A platform test with an AC induction machine of 1.5 CV was assembled for the comparative testing. The angular position sensor of the panel is implemented in a ATMega328 microcontroller coupled to an accelerometer, commanded by an Arduino prototyping board. The solar position is also calculated by the microcontroller from the geographic coordinates of the site where it was placed, and the local time and date obtained from an RTC (Real-Time Clock) device. A prototype of a solar tracker polar axis moved by a DC motor was assembled to certify the operation of the sensor and to check the tracking efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visual Odometry is the process that estimates camera position and orientation based solely on images and in features (projections of visual landmarks present in the scene) extraced from them. With the increasing advance of Computer Vision algorithms and computer processing power, the subarea known as Structure from Motion (SFM) started to supply mathematical tools composing localization systems for robotics and Augmented Reality applications, in contrast with its initial purpose of being used in inherently offline solutions aiming 3D reconstruction and image based modelling. In that way, this work proposes a pipeline to obtain relative position featuring a previously calibrated camera as positional sensor and based entirely on models and algorithms from SFM. Techniques usually applied in camera localization systems such as Kalman filters and particle filters are not used, making unnecessary additional information like probabilistic models for camera state transition. Experiments assessing both 3D reconstruction quality and camera position estimated by the system were performed, in which image sequences captured in reallistic scenarios were processed and compared to localization data gathered from a mobile robotic platform