4 resultados para Material did

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effect of supplements feeding on growth of calves grazing a Panicum maximum cv. Mombaça pasture during the dry season. The experimental design was a randomized blocks with three treatments and three replications. The treatments were: mineral salt ad libidum; multiple mixture (MM) fed at 0.2% of live weight (PV); and, concentrate feed (SC) fed at 0.7% of PV. Thirty six weaned calves averaging eight months and 192 kg of initial live weight were utilized. The masses and pasture components, nutritive value and rate of forage growth were evaluated. Animal performance was measured as average daily gain (ADG) and live weight gain (LWG). The supplemental feeding was adjusted after weighing. There was no difference between periods for forage mass and leaf: stem ratio. The highest values for forage green mass, leaf blades mass and stem percentage were observed in the first trial period. The canopy height and the available forage on offer did not differ among treatments. The percentage of dead was higher for the last periods of evaluation. The leaf: stem ratio and the leaf percentage were greater in the second period. There was significant difference (p<0,05) among treatments for the ADG and were 250, 460 and 770 g/day for salt, MM and SC, respectively. The biggest LWG was observed in the treatment SC. contents of PB, DIVMO, NDF and LDA on leaf blades, thatched roofs and dead material dead not differ among treatments. The highest GPV was observed in the SC treatment. The contents of PB, DIVMO, NDF and LDA for leaf blades stem and dead material did not differ among treatments. Independent of the use supplements , it is possible to keep steers gaining weight, during dry season, since the stocking rate is appropriately adjusted

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis Distance learning and didactic material: a study about the course Media in the education in Natal shows a research about the didactic material and its insertion in the distance training course to teachers. In this sense, this research aims to contribute to some universities with reflections about the way to elaborate the didactic material to the distance training course of teachers with the following specific objectives: a) identify some aspects in the didactic material in the extension course Media in the Education that difficult media usage by the teachers members of the course in the pedagogical practice; b) discuss about the way how didactic material to the distance training course to teachers has been created; c) stimulate teachers/members to integrate media in their teacher practice. For that reason, we have developed an action-research (THIOLLENT, 2011; FRANCO, 2005), based on it we elaborated a proposal do complement activities to the course Media in the Education that were applied to two classes during the fifth edition of this course. This research is presented in four steps: 1st) analyze of the course modules; 2nd) creation of a proposal to complement the activities; 3rd) applying the proposal to the students during the fifth edition to the course; 4th) analyze of forums and log books written by teachers/students. Data was analyzed by the contents perspective of Bardin (2011). As a theoretical support, we have Tardif (2012), about teachers knowledge; Dewey (1959; 2011) and Freire (2001; 2009; 2010a; 2010b; 2012) related to learning perspective; Candau (2002), Rays (2003) and Freire (2010a), about the relation theory x practice in the teacher training; Andrade (2003; 2009) and Belloni (2010) about distance teacher training; Bérvot; Belloni (2009), Neves; Medeiros (2005) and Prado (2005), related to Media integration. This research revealed the didactic material of the course Media in the Education has not a proposal to articulate theory and practice, due to this, this course opposed the Media integration. For that reason, teachers/members have real problems to integrate Media in their scholar routine. This research confirmed the way this didactic material was formulated did not help the teachers/students to integrate media in their pedagogical activities