4 resultados para Marginal gap
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The Knowledge Management in organizations is a continuous process of learning that is given by the integration of data, information and the ability of people to use this information. The Management Skills is concerned to understand the powers of officials in the face of organizational skills (teams) and professionals (or tasks positions) want. Joints are located in the greater context of the economy of organizatio s and have the same assumption: that the possession of scarce resources, valuable and difficult to imitate gives the organization a competitive advantage. In this sense, this thesis proposes a model of knowledge management based on analysis of GAP of powers, namely the gap between the skills needed to reach the expected performance and skills already available in the organization, officials and trainees of Coordination of Registration of conductors of DETRAN-RN. Using the method of survey research could make an analysis of academic skills, techniques and emotional individual and a team of officials and trainees, identifying levels of GAP's competence in that sector of the organization and suggest a plan for training , A level of expertise for each sector of coordination, and propose a model for Knowledge Management to help the management of GAP's identified
Resumo:
The theme of this work is the study of marginal territories of the Cidade do Príncipe, sketch in time than today is constituted as the city of Caicó/RN, with the time frame the years 1880 to 1900. Our goal is to investigate the construction of these territories from multiple speech subjects practitioners of the city. Thus, we propose to discover the mapping of the deviation in the city in question, as they were drawn, those who experienced and through which practices. Investigate the construction of these spaces from the speeches, and fill a historiographical gap, allows to find stories sharp, silenced or ignored, abortions and madness in prison, repressed passions and avenged. To meet these spaces the sources are diverse, such as the newspaper O Povo, the Codes of posture, the Reports of Presidents and Heads of Provincial Police and process-crime. Regarding the methodological aspects of research, we decided by discourse analysis, discourse here conceived not only as what is said about someone or something, but as a set of statements circulating at any given time in society, articulating speech, intentions, actions and thought. The city is then considered from their territories, imagined as a space configured in/by the relations power that the dispute, but also as a space for experiences multiple, different feelings, place and non-place, the discipline and mockery, of power and resistance.
Resumo:
Among the non-invasive techniques employed in the prevention of caries highlights the sealing pits and fissures which is a conservative maneuver, in order to obliterate them to protect them from attack acid bacteria. Influenced by the studies of pre-heating composite resin, which has experienced great improvement in some of their physical properties, this study aimed to evaluate in vitro the superficial and internal marginal adaptation of different materials and sealants in pre-heating or not. A total of 40 extracted human third molars (n=10) that had their occlusal surfaces prepared to receive sealant. We tested two types of sealing materials: resin sealant (Fluoroshield) and low-viscosity resin (Permaflo), where 50% of previously received heated material and the other half received sealant material at room temperature. All samples were subjected to thermal cycling and pH, simulating a cariogenic oral environment, and later were analyzed appliance OCT (optical coherence tomography). The images obtained alterations were recorded and analyzed statistically. Change was considered as the emergence of bubbles, gaps and cracks in the sealant. Comparisons of the same material, assessing the fact that it is not sealed or preheated material, as well as comparisons between different materials subjected to the same temperature were carried out. The nonparametric Tukey test was used (p < 0,05). The results showed that there was statistically significant difference between both the materials analyzed, as between the situations in which the sealant material was submitted (preheated or not). On the issue of marginal adaptation and internal surface, seen through Optical coherence tomography, may suggest that there is a difference between the use of one type or another of the sealing material analyzed, with superiority attributed to resin Permaflo compared to sealant Fluroshield, telling is the same for the different techniques used
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques