7 resultados para Log-normal distribution

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we analyze the skin bioimpedance statistical distribution. We focus on the study of two distinct samples: the statistics of impedance of several points in the skin of a single individual and the statistics over a population (many individuals) but in a single skin point. The impedance data was obtained from the literature (Pearson, 2007). Using the Shapiro-Wilk test and the assymmetry test we conclude that the impedance of a population is better described by an assymetric and non-normal distribution. On the other side, the data concerning the individual impedance seems to follow a normal distribution. We have performed a goodnes of fitting test and the better distribution to fit the data of a population is the log-normal distribution. It is interesting to note that our result for skin impedance is in simtony with body impedance from the literature of electrical engeneering. Our results have an impact over the statistical planning and modelling of skin impedance experiments. Special attention we should drive to the treatment of outliers in this kind of dataset. The results of this work are important in the general discussion of low impedance of points of acupuncture and also in the problem of skin biopotentials used in equipments like the Electrodermal Screen Tests.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to determine the influence of strength training (ST), in three weekly sessions over ten weeks, on cardiovascular parameters and anthropometric measurements. It is a before and after intervention trial, with a sample composed of 30 individuals. Participants were adults aged between 18 and 40 years, from both sexes and sedentary for at least three months previously. Tests were computed ergospirometry, CRP, PWV and body composition (dependent variables) before and after the experiment. Independent variables, age and sex, were considered in order to determine their influence on the dependent variablesevaluatedend. By comparing the initial cardiovascular parameters with those obtained after intervention in patients undergoing the ST proposed (a Student s t-test was conducted within each group for samples matched to parameters with normal distribution, while the Wilcoxin was applied for those without), there was no significant difference in PWV(p =0469) or PCR(p =0.247), but there was an increase in anaerobic threshold(AT) (p=0.004) and Maximal Oxygen Uptake(VO2max) (p =0.052). In regard to anthropometric measures, individuals significantly reduced their body fat percentage (p<0.001) and fat mass (p<0,001), as well as increasing lean mass (p<0.001). However, no changes were recorded in the waist-to-hip ratio (WHR) (p= 0.777), body mass (p=0.226) or body mass index (BMI) (p =0.212). Findings of this study lead us to believe that the proposed ST, and did not increase the VOP or PCR improves cardiorespiratory capacity and body composition. Devotees of this training can therefore safely enjoy all its benefits without risk to the cardiovascular system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The gestation process, in general, is a very important event on a woman’s life and it brings phisical, phisiological and emotional changes, which by itself is an experience full of intense feelings. By late-aged pregnancy we mean those which occurs at the age of 35 or further. The occurance of this type of pregnancy is rising in Brasil and throughout the world, factors such as, better access to birth control resources and the search for financial stability explains the pregnancy delay. Important processes like resilience and social support can help late-aged pregnant women, in a benefical way, to adapt to the gestation process. Resilience is the capacity that a certain individual or group of individuals have to go through an adverse situation, be able to overcome it and become streghtened, transforming it in motivation for its biopsichosocial development. Social support is a complex and dinamic process that involves transactions between individuals and their social networks, meeting the social needs, promoting and complementing the personal resources that they have to face new demands. This research has the intention of raising information about the issues of late-aged pregnant women in the County of Natal- RN, the main objective was to evaluate the resilience indicators and the social support on late-aged pregnant women in the Natal-RN County. A transversal cut, correlational and descriptive research that was done with 150 lateaged pregnant women. The tools that were used were: A form with sociodemographic and gestation info, the scale of resilience and social support. An eletronic spreadsheet sofware (Excel e SPSS 21.0) was used to analize data which helped on the statistics according to its variables and the objective of this work. For the nominal variables, relative frequencies were used and for continuous the Pearson correlation and determination coefficient were used, regarding that; the sample had a normal distribution. The project fulfilled the ethnic aspects prescribed by Resolution 466/12 of the National Health Council, with a favorable decision (356.436/ 2013) of the UFRN Ethics on Research Committee. Most of the pregnant women had a low money income and education level, born in the state of Rio Grande do Norte they had an average age of 37,49 (±2,577), catholic, married, house wives, they had more than one child and were on their third trimester of pregnancy; they also had a low past abortion rate, not having planned their pregnancy, with an average of 4,22 (±2,506) pre-natal appointments, residing with an average of 3,673 (±1,397) people, having used any sort of birth control device and having high indicators of resilience and social support. The correlations kept between resilience, social support and some of the social demographics and gestation variables were considered low. Such data points out the fact that most of these women were in a stable relationship; they hadn’t had a past of abortion, they were involved with some kind of religion, they were not first pregnancy mothers, had an age on which they are not considered inexperienced mothers and even had scored high on the social support scale, these may all possibly be the most contributing factors on development and resilience building on these 35 years or more mothers. We expect that the data and information from this research may add up knowledge, actions and improvements regarding late-aged pregnant women and the pregnancy phenomena in general.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cephalometric analysis is the mensuration of linear and angular measures through demarcation points as distances and lines on teleradiography, and is considered of fundamental importance for diagnosis and orthodontic planning. In this manner, the objective of this research was to compare cephalometric measurements obtained by dentists and radiologists from the analysis of the same radiograph, in a computerized cephalometric analysis program. All research participants marked 18 cephalometric points on a 14-inch notebook computer, as directed by the program itself (Radiocef 2®). From there, they generated 14 cephalometric parameters including skeletal, dental-skeletal, dental and soft tissue. In order to verify the intra-examiner agreement, 10 professionals from each group repeated the marking of the points with a minimum interval of eight days between the two markings. The intra-group variability was calculated based on the coefficients of variation (CV). The comparison between groups was performed using the Student t-test for normally distributed variables, and using the Mann-Whitney test for those with non-normal distribution. In the group of orthodontists, the measurements of Pog and 1-NB, SL, S-Ls Line, S-Li Line and 1.NB showed high internal variability. In the group of radiologists, the same occurred with the values of Pog and 1-NB, S-Ls Line, S-Li Line and 1.NA. In the comparison between groups, all the analyzed linear values and two angular values showed statistically significant differences between radiologists and dentists (p <0.05). According to the results, the interexaminer error in cephalometric analysis requires more attention, but does not come from a specific class of specialists, being either dentists or radiologists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diabetes Mellitus (DM ) is a complex disease that requires continuous medical care for the reduction of risk factors in addition to glycemic control. The typical hyperglycemia of this disease produces glycosylation of proteins and so the consequence is the accumulation of glycosylation final products in various human tissues, among them, the tendon. The aerobic exercise (AE) and the low level laser therapy (LLLT) have been used to treat tendinopathies in individuals with or without DM. Objective: The aim of this study was to watch the effect of the LLLT and the AE, in association, in partial tenotomy of the tissue repair of the Achilles tendon (AT) of diabetic rats. Methods: 91 animals were utilized and divided in to the following groups: control group (GC), injured control group (GCL), diabetic group (GD), diabetic group LLLT (GD – TLBI), diabetic group trained (GD - EX) and diabetic group trained laser (GD-EX+TLBI). The animals were submitted to intervention with AE, using a protocol with a progressive increase of time (12 to 60 min) and speed of (4 to 9 m/min), and the LLLT (660 nm laser, 10mW, 4 J/cm², single point for 16 seconds, three times for week). It was analyzed morphological, biomechanical and molecular characteristics. For data showing normal distribution was used one-way ANOVA test and post hoc Tukey and data without normal distribution was used Mann Whitney test and post hoc Dunn's. It was accepted p <0.05 for statistical significance Results: The biomechanical tests indicated major improvement in the GC and GD-EX+TLBI groups when compared with the diabetic groups in the following variables: maximum load, strain, absorbed energy, stress, cross section area, elastic modulus and energy density (p<0.05). The analysis through molecular biology indicated that the association of aerobic exercise and LLLT generated an increase of the collagen I gene expression and modulated the expression of the MMP2 and MMP9 (p<0.05). No observed any major improvement in the morphological variable studied. Conclusion: the LLLT associated with aerobic exercise promotes and increase of the mechanical properties, in the control of collagen I gene expression and of the MMP2 and MMP9 of the diabetic rats.