6 resultados para Local characteristics
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
The semiarid rainfall regime is northeastern Brazil is highly variable. Climate processes associated with rainfall are complex and their effects may represent extreme situations of drought or floods, which can have adverse effects on society and the environment. The regional economy has a significant agricultural component, which is strongly influenced by weather conditions. Maximum precipitation analysis is traditionally performed using the intensity-duration-frequency (IDF) probabilistic approach. Results from such analysis are typically used in engineering projects involving hydraulic structures such as drainage network systems and road structures. On the other hand, precipitation data analysis may require the adoption of some kind of event identification criteria. The minimum inter-event duration (IMEE) is one of the most used criteria. This study aims to analyze the effect of the IMEE on the obtained rain event properties. For this purpose, a nine-year precipitation time series (2002- 2011) was used. This data was obtained from an automatic raingauge station, installed in an environmentally protected area, Ecological Seridó Station. The results showed that adopted IMEE values has an important effect on the number of events, duration, event height, mean rainfall rate and mean inter-event duration. Furthermore, a higher occurrence of extreme events was observed for small IMEE values. Most events showed average rainfall intensity higher than 2 mm.h-1 regardless of IMEE. The storm coefficient of advance was, in most cases, within the first quartile of the event, regardless of the IMEE value. Time series analysis using partial time series made it possible to adjust the IDF equations to local characteristics
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
In the design of a building process must consider climatic variations in the region, the external conditions and the use of available resources in nature, like the sun, vegetation, rain and winds, to provide a built environment with comfort and environment reduced energy expenditure. However, increasing urbanization, often with an occupancy of disordered ground comes disregarding this knowledge and disregarding local characteristics, drastically reducing the green areas. This disordered occupation associated with the reduction of green spaces, is modifying aspects of climate and thus, damaging the thermal comfort of users. Given this situation was born the question: What projetuais strategies can bring better thermal conditions to an educational building located in a region of hot and humid weather? Thus, faced with two important issues , education and environmental comfort , the research is justified by the fact that there is a large national demand for expansions and renovations in its public schools , but not in most areas provides students with quality for good learning development. This paper aims to draw up a project for establishment of Primary Education with the application of the concepts of bioclimatic, highlighting the use of vegetation as a regulatory element of the climate. Initially we carried out a literature search; we analyzed architectural solutions and set up the site. The next phases, called understanding, were raised with the laws, rules and environmental restrictions. Subsequently, the program needs and the development of architectural design was defined. The conclusion of this paper presents the definition of criteria and solutions for the use of vegetation to design of bioclimatic architecture in hot and humid climates and contributes a catalog of plant species for schools in the metropolitan region of Natal, RN.
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
The main inputs to the hippocampus arise from the entorhinal cortex (EC) and form a loop involving the dentate gyrus, CA3 and CA1 hippocampal subfields and then back to EC. Since the discovery that the hippocampus is involved in memory formation in the 50's, this region and its circuitry have been extensively studied. Beyond memory, the hippocampus has also been found to play an important role in spatial navigation. In rats and mice, place cells show a close relation between firing rate and the animal position in a restricted area of the environment, the so-called place field. The firing of place cells peaks at the center of the place field and decreases when the animal moves away from it, suggesting the existence of a rate code for space. Nevertheless, many have described the emergence of hippocampal network oscillations of multiple frequencies depending on behavioral state, which are believed to be important for temporal coding. In particular, theta oscillations (5-12 Hz) exhibit a spatio-temporal relation with place cells known as phase precession, in which place cells consistently change the theta phase of spiking as the animal traverses the place field. Moreover, current theories state that CA1, the main output stream of the hippocampus, would interplay inputs from EC and CA3 through network oscillations of different frequencies, namely high gamma (60-100 Hz; HG) and low gamma (30-50 Hz; LG), respectively, which tend to be nested in different phases of the theta cycle. In the present dissertation we use a freely available online dataset to make extensive computational analyses aimed at reproducing classical and recent results about the activity of place cells in the hippocampus of freely moving rats. In particular, we revisit the debate of whether phase precession is due to changes in firing frequency or space alone, and conclude that the phenomenon cannot be explained by either factor independently but by their joint influence. We also perform novel analyses investigating further characteristics of place cells in relation to network oscillations. We show that the strength of theta modulation of spikes only marginally affects the spatial information content of place cells, while the mean spiking theta phase has no influence on spatial information. Further analyses reveal that place cells are also modulated by theta when they fire outside the place field. Moreover, we find that the firing of place cells within the theta cycle is modulated by HG and LG amplitude in both CA1 and EC, matching cross-frequency coupling results found at the local field potential level. Additionally, the phase-amplitude coupling in CA1 associated with spikes inside the place field is characterized by amplitude modulation in the 40-80 Hz range. We conclude that place cell firing is embedded in large network states reflected in local field potential oscillations and suggest that their activity might be seen as a dynamic state rather than a fixed property of the cell.