8 resultados para Insolação
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN
Resumo:
Nowadays the acquisition of sustainable elements and concepts in construction has been increasingly discussed, improved and incorporated to buildings, since the sector directly interferes in the urban space and environment, representing environmental impact. In order to make a sustainable building (Green Building) it is vital to incorporate less damaging constructive practice, starting from the project until the operation of the enterprise, that means to consider an integrated process of conception, implementation, construction and operation. The more effective sustainable principles participation in architecture happens at the projecting step through minimal environment impact solutions. Among the issues varieties that goes with sustainability proposal of the buildings project, there were added to this work the elements that are directly attached to bioclimatic architecture, more specifically the climate variation, ventilation, lighting and sunlight, that directly affect the project conception. It is important to put in evidence that architecture role goes far beyond the simple activity of building spaces; it is the sequence of political, economic, social and cultural elements, having the users as the main apparatus to its materialization. Thereby this professional dissertation consists of an architecture draft for a professional and technological school in the Rio Grande do Norte State, this dissertation is based on the analysis of previous experience and the bioclimatic principles that implicate in building on hot and dry, hot and humid climates, and the use of strategic solutions that aim the optimization of natural light and ventilation
Resumo:
This study evaluates the influence of depth and environmental parameters on the development of Gracilaria birdiae Plastino & Oliveira (Gracilariaceae Rhodophyta) in an organic shrimp pound (Litopenaeus vannamei) under euthrophical conditions. PVC structures (module) witch four ropes laden with 150 g of macroalgae each, were kept during 35 days at three different depths (surface, 10 and 20 cm depth). Wet biomass weighing and environmental parameters (temperature, salinity, turbidity, pH, transparence, precipitation, evaporation, insolation, accumulated solar radiation, nitrite, nitrate, ammonium and orthophosphate) were measured weekly. At all three proposed depths, the macroalgae displayed a higher biomass at the end of experiment than at the initial inoculations. The module kept at a 10 cm depth presented the greatest average biomass (186,3), followed by that kept at 20 cm (180,4 g) and the surface module (169,9 g). Biomass variations showed algae to suffer the direct effects of depths. Biomass loss was associated with the factors that influence light penetration, such as sediment deposits above the thallus, rate of evaporation and precipitation. The smallest loses occurred in the algae kept on surface (0,16%), followed by the algae kept at 20 cm (0,20%) and 10 cm (0,22%). The specific growth rate (SGR) of G. birdiae showed no significant difference between the three depths nor the sample periods. Nevertheless, the modules kept at 10 and 20 cm depths presented similar growth evolution, both growing 0,38%·per day-1, while the module kept on surface had an average SGR of 0,36%·day-1. The models related to growth rate demonstrated temperature, salinity, pH, orthophosphate, ammonium, precipitation and turbidity as the principal environmental parameters influencing the development of G. birdiae
Resumo:
This study addresses the environmental quality in therapeutic spaces for children's rehabilitation. The assumption that space is active and interfere in interpersonal relationships, highlights the importance of natural light to the hospital architecture, to foster the creation of environments that encourage and assist in the recovery of patients in the rehabilitation process. Therefore, interferes with health humanization through positive actions in the physiological and emotional effects of natural light, as facilitators of the health recovery process. In Brazil hospital openings systems projects are built exclusively to follow requirements of the local construction code which do not consider the landscape, but only ventilation and heat stroke; and the luminance levels are treated just as recommendations for artificial lighting. The National Policy for Healthcare Humanization presents the environmental comfort as a priority. However, it does not guidelines for achieving it. In this context this research aims to evaluate the lighting comfort in infant therapeutic areas from the professional satisfaction, in order to identify human preferences on the variables: technical and constructive aspects, relationship with the exterior, internal visual interface and quality elements. With this purpose it was adopted as research strategy the Post-Occupancy Evaluation (Technical Functional) through a multi method approach, which included a case study in the rehabilitation gym of Children Rehabilitation Center, at Natal, Rio Grande do Norte, and a reference study at SARAH Rehabilitation Center, Fortaleza Unit at Ceará, both in Brazil northeast. The results indicate that the definition of openings systems should consider external and internal factors to the building, as the natural landscape, the immediate surroundings and activities to be performed. The POE found out the preference of the professional visual privacy in detriment to other analyzed aspects. Thus, it is expected that this study can contribute to the discussion of luminous quality and generate inputs for future projects or renovations in the Children's Rehabilitation Centers, which should not be projected as hospitals
Resumo:
The climate is still main responsible for the variations soybean productivity (Glycine max (L.) Merrill), exerting a limiting action on these agricultural systems. The bomjesuense cerrado, this culture has proved, over the years, an increase of cultivated areas, however, productivity does not keep the same pace, going through periods of oscillations. Thus, although the crop is added to high technology, culture has great vulnerability to climatic adversities. Thus, the present study aims to analyze possible trends in meteorological variables, which can influence the soybean yield in Bom Jesus. For this purpose, different datasets were used, as follows: i) two periods of daily data (1984-2014 and 1974-2014), both obtained from the National Meteorological Institute (INMET); ii) climate normals from 1961-1990 as defined by INMET; iii) local agricultural production data of soybean-year (1997/1998 to 2012/2013) obtained from the Municipal Agricultural Production (PAM) dataset, which is management by Brazilian Institute of Geography and Statistics (IBGE). The analysis procedures included calculations of climate normals for 1984 to 2014 period and some statistical applications, as follows: i) the Wilcoxon test, used to evaluate differences between climate normals (1961 to 1990 and 1984 to 2014); ii) the Mann-Kendall nonparametric test, in order to analyze the linear trend of agrometeorological variables (rainfall, maximum temperature, minimum temperature and diurnal range of temperature; iii) cluster analysis by Ward method and the Spearman correlation test (rs) to identify the relationship between agrometeorological variable and soybean annual productivity. We adopted a statistical significance level of 5%. The results indicate changes in seasonality of the 1984-2014 climatology with respect to past climatology for all variables analyzed, except for insolation and precipitation. However, the monthly analysis of precipitation indicate negative trend during October and positive trend in December, causing a delay in start of rainy season. If this trend is persistent this result must be considered in futures definitions of the soybean crop sowing date over the region studied. With Mann-Kendall test was possible to identify positive trends with statistical significance in maximum temperature for all month forming part of soybean cycle (from November to April), which in turn tends to cause adverse effects on crop physiology, and consequently impacts on the final yield. Was identified a significant positive correlation between soybean yield and precipitation observed in March, thus precipitation deficit in this month is harmful to the soybean crop development. No statistically significant correlation was identified among maximum temperature, minimum temperature, and DTR with annual soybean productivity due these range of meteorological variables are not limiting factors in the final soybean yield in Bom Jesus (PI). It is expected that this study will contribute to propose planning strategies considering the role of climate variability on soybean crop final yield.
Resumo:
The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN
Resumo:
Nowadays the acquisition of sustainable elements and concepts in construction has been increasingly discussed, improved and incorporated to buildings, since the sector directly interferes in the urban space and environment, representing environmental impact. In order to make a sustainable building (Green Building) it is vital to incorporate less damaging constructive practice, starting from the project until the operation of the enterprise, that means to consider an integrated process of conception, implementation, construction and operation. The more effective sustainable principles participation in architecture happens at the projecting step through minimal environment impact solutions. Among the issues varieties that goes with sustainability proposal of the buildings project, there were added to this work the elements that are directly attached to bioclimatic architecture, more specifically the climate variation, ventilation, lighting and sunlight, that directly affect the project conception. It is important to put in evidence that architecture role goes far beyond the simple activity of building spaces; it is the sequence of political, economic, social and cultural elements, having the users as the main apparatus to its materialization. Thereby this professional dissertation consists of an architecture draft for a professional and technological school in the Rio Grande do Norte State, this dissertation is based on the analysis of previous experience and the bioclimatic principles that implicate in building on hot and dry, hot and humid climates, and the use of strategic solutions that aim the optimization of natural light and ventilation
Resumo:
This study evaluates the influence of depth and environmental parameters on the development of Gracilaria birdiae Plastino & Oliveira (Gracilariaceae Rhodophyta) in an organic shrimp pound (Litopenaeus vannamei) under euthrophical conditions. PVC structures (module) witch four ropes laden with 150 g of macroalgae each, were kept during 35 days at three different depths (surface, 10 and 20 cm depth). Wet biomass weighing and environmental parameters (temperature, salinity, turbidity, pH, transparence, precipitation, evaporation, insolation, accumulated solar radiation, nitrite, nitrate, ammonium and orthophosphate) were measured weekly. At all three proposed depths, the macroalgae displayed a higher biomass at the end of experiment than at the initial inoculations. The module kept at a 10 cm depth presented the greatest average biomass (186,3), followed by that kept at 20 cm (180,4 g) and the surface module (169,9 g). Biomass variations showed algae to suffer the direct effects of depths. Biomass loss was associated with the factors that influence light penetration, such as sediment deposits above the thallus, rate of evaporation and precipitation. The smallest loses occurred in the algae kept on surface (0,16%), followed by the algae kept at 20 cm (0,20%) and 10 cm (0,22%). The specific growth rate (SGR) of G. birdiae showed no significant difference between the three depths nor the sample periods. Nevertheless, the modules kept at 10 and 20 cm depths presented similar growth evolution, both growing 0,38%·per day-1, while the module kept on surface had an average SGR of 0,36%·day-1. The models related to growth rate demonstrated temperature, salinity, pH, orthophosphate, ammonium, precipitation and turbidity as the principal environmental parameters influencing the development of G. birdiae