4 resultados para Humid Tropical Queensland

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Visceral Leishmaniose (LV) disease is endemic in some places in Brazil. It is caused by the protozoa Leishmania chagasi, being transmitted for vector, the phlebotomies, Lutzomyia longipalpis. In virtue of the expansion of the illness in Rio Grande do Norte, it is necessary to evaluate the determinative ambient factors in the proliferation of the vector for better control of the illness. The variable rainfall and the social variables had been analyzed using space regression with two models and the ambient variable of ZANE and the variables analyzed in 205 houses in the cities of Natal, Extremoz, Nísia Floresta, São Gonçalo do Amarante, São Jose do Mipibu, Parnamirim and Macaíba the Person and ML Chi-square were used . The analyses had shown that high rainfall, plain relief, the forest, the humid tropical climate the activities of production culture of sugar cane and fruit culture and the presence of bovines increase the risk of the LV. The work showed that it has space aggregation and that ambient factors influence in the LV in the State

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Visceral Leishmaniose (LV) disease is endemic in some places in Brazil. It is caused by the protozoa Leishmania chagasi, being transmitted for vector, the phlebotomies, Lutzomyia longipalpis. In virtue of the expansion of the illness in Rio Grande do Norte, it is necessary to evaluate the determinative ambient factors in the proliferation of the vector for better control of the illness. The variable rainfall and the social variables had been analyzed using space regression with two models and the ambient variable of ZANE and the variables analyzed in 205 houses in the cities of Natal, Extremoz, Nísia Floresta, São Gonçalo do Amarante, São Jose do Mipibu, Parnamirim and Macaíba the Person and ML Chi-square were used . The analyses had shown that high rainfall, plain relief, the forest, the humid tropical climate the activities of production culture of sugar cane and fruit culture and the presence of bovines increase the risk of the LV. The work showed that it has space aggregation and that ambient factors influence in the LV in the State

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential