6 resultados para Head space-solid phase micro extraction
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic
Resumo:
Alcohol is one of the few psychotropic drugs that their consumption has admitted legally and sometimes encouraged by the society. Studies show alcohol as the highest consumption of drugs among young people and society in general, probably because of its availability and easy access. The abuse causes public health problems, which was closely related to the violence, socioeconomic problems and the high number of automobile accidents. Transit is one of the main sectors affected by the effects of alcohol, observing a high incidence in the studies. About half of automobile accidents occurs after the consumption of alcoholic beverage, and the vast majority of cases related to high concentrations of alcohol in the bloodstream. The relationship of drunk with traffic accidents is in fact evident everywhere in the world, including Brazil, where studies have shown a high relationship between alcohol consumption and traffic accidents. This study determined the alcohol in fatal victims of traffic accidents in the state of Rio Grande do Norte and established the profile of this population compared with those found in Brazil and other countries. Samples of blood of ethanol added to fulfillment of the standardization of chromatographic conditions and procedures for the analysis, being employed in the determination of alcohol in blood samples of 277 victims of traffic accidents, collected at the Institute of Scientific Technical Police of Rio Grande do North (ITEP) in the year 2007. The blood alcohol level was determined in these samples correlated with the sex, age and marital status of the victim and the location, day of week and month when the accident occurred, is doing a statistical analysis and outlining a profile of the victims of an accident at transit in the state of Rio Grande do Norte. The parameters of standardization studied ensured the quality of the analytical method and, consequently, to obtain reliable laboratory results. Being given the best temperature for injector (150 ºC), detector (250 ºC) and column (50 ºC) with a flow of gas in the column of 2mL/minutos and analysis of time of 12 minutes. The method was linear in the range of 0.01 to 3.2 g / L (r2 = 0.9989) with average recovery of 100.2% and precision with coefficient of variation less than 15%. The analysis carried out on victims of fatal road traffic accidents, ethanol detected in the blood in 66.43% of the victims and these, 96% showed concentration ≥ 0.2 g / L, 87.73% of victims were male, while 12.27% female. The younger age group (1535 years) was the most involved (52,35%) and most single (55.60%). The accidents occurred with greater prevalence in the day on Monday (27%) followed by Sunday (24,19%) and Saturday (15,52%) and it was found that the prevalence of injuries varied between the different months of the year, and in February (14.4%) and April (10.47%) the months that had a higher number of accidents, however this oscillation showed no statistically significant difference. Also no significant difference was observed between the tracks of concentration found in men and women. The standardized method showed to be efficient, given satisfactorily to the goals of this work, and the high levels of alcohol found in victims of fatal road traffic accidents are consistent with several studies of literature, and the profile of the victim also supported by presenting in its most young adults, male and single
Resumo:
The oil and petrochemical industry is responsable to generate a large amount of waste and wastewater. Among some efluents, is possible find the benzene, toluene, ethilbenze and isomers of xilenes compounds, known as BTEX. These compounds are very volatily, toxic for environment and potencially cancerigenous in man. Oxidative advanced processes, OAP, are unconventional waste treatment, wich may be apply on treatment and remotion this compounds. Fenton is a type of OAPs, wich uses the Fenton s reactant, hydrogen peroxide and ferrous salt, to promove the organic degradation. While the Photo-Fenton type uses the Fenton s reactant plus UV radiation (ultraviolet). These two types of OAP, according to literature, may be apply on BTEX complex system. This project consists on the consideration of the utilization of technologies Fenton and Photo-Fenton in aqueous solution in concentration of 100 ppm of BTEX, each, on simulation of condition near of petrochemical effluents. Different reactors were used for each type of OAP. For the analyticals results of amount of remotion were used the SPME technique (solid phase microextraction) for extraction in gaseous phase of these analytes and the gas chromatography/mass espectrometry The arrangement mechanical of Photo-Fenton system has been shown big loss by volatilization of these compounds. The Fenton system has been shown capable of degradate benzene and toluene compounds, with massic percentage of remotion near the 99%.
Resumo:
This dissertation aims the development of an experimental device to determine quantitatively the content of benzene, toluene and xylenes (BTX) in the atmosphere. BTX are extremely volatile solvents, and therefore play an important role in atmospheric chemistry, being precursors in the tropospheric ozone formation. In this work a BTX new standard gas was produced in nitrogen for stagnant systems. The aim of this dissertation is to develop a new method, simple and cheaper, to quantify and monitor BTX in air using solid phase microextraction/ gas chromatography/mass spectrometry (SPME/CG/MS). The features of the calibration method proposed are presented in this dissertation. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fiber exposed for 10 min standard gas mixtures. It is observed that the main parameters that affect the extraction process are sampling time and concentration. The results of the BTX multicomponent system studied have shown a linear and a nonlinear range. In the non-linear range, it is remarkable the effect of competition by selective adsorption with the following affinity order p-xylene > toluene > benzene. This behavior represents a limitation of the method, however being in accordance with the literature. Furthermore, this behavior does not prevent the application of the technique out of the non-linear region to quantify the BTX contents in the atmosphere.
Resumo:
Biosurfactants are molecules produced by microorganisms mainly bacteria as Pseudomonas and Bacillus. Among the biosurfactants, rhamnolipids play an important role due to their tensoactive as well as emulsifying properties. Besides can be produced in a well consolidated way the production costs of biosurfactants are quite expansive mainly if downstream processing is goning to be considered. Actually, attention has been given to identification of biosurfactants as well as optimization of its fermentative processes including downstream ones. This work deals with the development of strategies to recovery and purification of rhamnolipids produced by Pseudomonas aeruginosa P029-GVIIA using sugar-cane molasses as substrate. Broth free of cells was used in order to investigate the best strategies to recovery and purification produced by this system. Between the studied acids (HCl and H2SO4) for the acid precipitation step, HCl was the best one as has been showed by the experimental design 24. Extraction has been carried out using petroleum ether and quantification has been done using the thioglycolic acid method. Adsorption studies were carried out with activated carbon in a batch mode using a 24 experimental design as well as combined with an hydrophobic resin Streamline Phenyl aiming to separate the produced biosurfactant. Biosurfactant partial identification was carried out using High Performance Liquid Chromatography (HPLC). Experiments in batch mode showed that adsorption has been controlled mainly by pH and temperature. It was observed a reduction of 41.4% for the liquid phase and the solid phase it was possible to adsorb up to 15 mg of rhamnolipd/g of activated carbon. The kinetics of adsorption has been well fitted to a pseudo-first order reaction with velocity constant (k1) of 1.93 x 10-2 min-1. Experiments in packed bed ranging concentration on eluent (acetone) has been shown the highest recovery factor of 98% when pure acetone has been used. The combined effect if using activated carbon with an hydrophobic resin Streamline Phenyl has been shown successful for the rhamnolipids purification. It has been possible to purify a fraction of the crude broth with 98% of purity when the eluted of activated carbon packed bed was used with pure acetone
Resumo:
Leather tanneries generate effluents with high content of heavy metals, especially chromium, which is used in the mineral tanning process. Microemulsions have been studied in the extraction of heavy metals from aqueous solutions. Considering the problems related with the sediment resulting from the tanning process, due to its high content in chromium, in this work this sediment was characterized and microemulsion systems were applied for chromium removal. The extraction process consists in the removal of heavy metal ions present in an aqueous feeding solution (acid digestion solution) by a microemulsion system. First three different solid sludge digestion methods were evaluated, being chosen the method with higher digestion capacity. For this digestion method, seeking its optimization, was evaluated the influence of granule size, temperature and digestion time. Experimental results showed that the method proposed by USEPA (Method A) was the most efficient one, being obtained 95.77% of sample digestion. Regarding to the evaluated parameters, the best results were achieved at 95°C, 14 Mesh granule size, and 60 minutes digestion time. For chromium removal, three microemulsion extraction methods were evaluated: Method 1, in a Winsor II region, using as aqueous phase the acid digestion solution; Method 2, in a Winsor IV region, being obtained by the addition of the acid digestion solution to a microemulsion phase, whose aqueous phase is distilled water, until the formation of Winsor II system; and Method 3, in a Winsor III region, consisting in the formation of a Winsor III region using as aqueous phase the acid digestion solution, diluted in NaOH 0.01N. Seeking to optimize the extraction process only Method 1 (Systems I, II, and VIII) and Method 2 (System IX) were evaluated, being chosen points inside the interest regions (studied domains) to study the influence of contact time and pH in the extraction percentiles. The studied systems present the following compositions: System I: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase 2% NaCl solution; System II: Aqueous phase Acid digestion solution with pH adjusted using KOH (pH 3.5); System VIII: Aqueous phase - Acid digestion solution (pH 0.06); and System IX Aqueous phase Distilled water (pH 10.24), the other phases of Systems II, VIII and IX are similar to System I. Method 2 showed to be the more efficient one regarding chromium extraction percentile (up to 96.59% - pH 3.5). Considering that with Method 2 the microemulsion region only appears in the Winsor II region, it was studied Method 3 (System X) for the evaluation and characterization of a triphasic system, seeking to compare with a biphases system. System X is composed by: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase Acid digestion solution diluted with water and with its pH adjusted using 0.01N NaOH solution. The biphasic and triphasic microemulsion systems were analyzed regarding its viscosity, extraction efficiency and drop effective diameter. The experimental results showed that for viscosity studies the obtained values were low for all studied systems, the diameter of the drop is smaller in the Winsor II region, with 15.5 nm, reaching 46.0 nm in Winsor III region, being this difference attributed to variations in system compositions and micelle geometry. In chromium extraction, these points showed similar results, being achieved 99.76% for Winsor II system and 99.62% for Winsor III system. Winsor III system showed to be more efficient due to the obtaining of a icroemulsion with smaller volume, with the possibility to recover the oil phase in excess, and the use of a smaller proportion of surfactant and cosurfactant (C/S)