6 resultados para Gold standard.

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Amphotericin B (AmB), an antifungal agent that presents a broad spectrum of activity, remains the gold standard in the antifungal therapy. However, sometimes the high level of toxicity forbids its clinical use. The aim of this work was to evaluate and compare the efficacy and toxicity in vitro of Fungizon™ (AmB-D) and two new different AmB formulations. Methods: three products were studied: Fungizon™, and two Fungizon™ /Lipofundin™ admixtures, which were diluted through two methods: in the first one, Fungizon™ was previously diluted with water for injection and then, in Lipofundin™ (AmB-DAL); the second method consisted of a primary dilution of AmB-D as a powder in the referred emulsion (AmB-DL). For the in vitro assay, two cell models were used: Red Blood Cells (RBC) from human donors and Candida tropicallis (Ct). The in vitro evaluation (K+ leakage, hemoglobin leakage and cell survival rate-CSR) was performed at four AmB concentrations (from 50 to 0.05mg.L-1). Results: The results showed that the action of AmB was not only concentration dependent, but also cellular type and vehicle kind dependent. At AmB concentrations of 50 mg.L-1, although the hemoglobin leakage for AmB-D was almost complete (99.51), for AmB-DAL and AmB-DL this value tended to zero. The p = 0.000 showed that AmB-D was significantly more hemolytic. Conclusion: The Fungizon™- Lipofundin™ admixtures seem to be the more valuable AmB carrier systems due to their best therapeutic index presented

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Breast cancer, despite being one of the leading causes of death among women worldwide is a disease that can be cured if diagnosed early. One of the main techniques used in the detection of breast cancer is the Fine Needle Aspirate FNA (aspiration puncture by thin needle) which, depending on the clinical case, requires the analysis of several medical specialists for the diagnosis development. However, such diagnosis and second opinions have been hampered by geographical dispersion of physicians and/or the difficulty in reconciling time to undertake work together. Within this reality, this PhD thesis uses computational intelligence in medical decision-making support for remote diagnosis. For that purpose, it presents a fuzzy method to assist the diagnosis of breast cancer, able to process and sort data extracted from breast tissue obtained by FNA. This method is integrated into a virtual environment for collaborative remote diagnosis, whose model was developed providing for the incorporation of prerequisite Modules for Pre Diagnosis to support medical decision. On the fuzzy Method Development, the process of knowledge acquisition was carried out by extraction and analysis of numerical data in gold standard data base and by interviews and discussions with medical experts. The method has been tested and validated with real cases and, according to the sensitivity and specificity achieved (correct diagnosis of tumors, malignant and benign respectively), the results obtained were satisfactory, considering the opinions of doctors and the quality standards for diagnosis of breast cancer and comparing them with other studies involving breast cancer diagnosis by FNA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Inaccurate diagnosis of vulvovaginitis generates inadequate treatments that cause damages women's health. Objective: evaluate the effectiveness of methods when diagnosing vulvovaginitis. Method: a cross-sectional study was performed with 200 women who complained about vaginal discharge. Vaginal smear was collected for microbiological tests, considering the gram stain method as gold standard. The efficacy of the available methods for diagnosis of vaginal discharge was assessed (sensitivity, specificity, positive predictive value and negative predictive value). Data were inserted to Graphpad Prism 6, for statistical analysis. Results: the following results were obtained: wet mount for vaginal candidiasis: sensitivity = 31%; specificity = 97%; positive predictive value (PPV) = 54%; negative predictive value (NPV) =93%; accuracy = 91%. Wet mount for bacterial vaginosis: sensitivity = 80%; specificity =95%; positive predictive value (PPV) = 80%; negative predictive value (NPV) = 95%; accuracy = 92%. Syndromic approach for bacterial vaginosis: sensitivity = 95%; specificity=43%; positive predictive value (PPV) =30%; negative predictive value (NPV) = 97%; accuracy = 54%. Syndromic approach for vaginal candidiasis: sensitivity = 75%; specificity =91%; positive predictive value (PPV) = 26%; negative predictive value (NPV) = 98%; accuracy = 90%. Pap smear for vaginal candidiasis: sensitivity = 68%, specificity = 98%; positive predictive value (PPV) = 86%; negative predictive value (NPV) =96%; accuracy = 96%. Pap smear for bacterial vaginosis: sensitivity = 75%; specificity = 100%; positive predictive value (PPV) = 100%; negative predictive value (NPV) =94%; accuracy = 95%. There was only one case of vaginal trichomoniasis reported – diagnosed by oncological cytology and wet mount – confirmed by Gram. The syndromic approach diagnosed it as bacterial vaginosis. From the data generated and with support on world literature, the Maternidade Escola Januário Cicco’s vulvovaginitis protocol was constructed. Conclusion: Pap smear and wet mount showed respectively low and very low sensitivity for vaginal candidiasis. Syndromic approach presented very low specificity and accuracy for bacterial vaginosis, which implies a large number of patients who are diagnosed or treated incorrectly.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chronic Hepatitis C is the leading cause of chronic liver disease in advanced final stage of hepatocellular carcinoma (HCC) and of death related to liver disease. Evolves progressively in time 20-30 years. Evolutionary rates vary depending on factors virus, host and behavior. This study evaluated the impact of hepatitis C on the lives of patients treated at a referral service in Hepatology of the University Hospital Onofre Lopes - Liver Study Group - from May 1995 to December 2013. A retrospective evaluation was performed on 10,304 records, in order to build a cohort of patients with hepatitis C, in which all individuals had their diagnosis confirmed by gold standard molecular biological test. Data were obtained directly from patient charts and recorded in an Excel spreadsheet, previously built, following an elaborate encoding with the study variables, which constitute individual data and prognostic factors defined in the literature in the progression of chronic hepatitis C. The Research Ethics Committee approved the project. The results were statistically analyzed with the Chi-square test and Fisher's exact used to verify the association between variable for the multivariate analysis, we used the Binomial Logistic regression method. For both tests, it was assumed significance p < 0.05 and 95%. The results showed that the prevalence of chronic hepatitis C in NEF was 4.96 %. The prevalence of cirrhosis due to hepatitis C was 13.7%. The prevalence of diabetes in patients with Hepatitis C was 8.78 % and diabetes in cirrhotic patients with hepatitis C 38.0 %. The prevalence of HCC was 5.45%. The clinical follow-up discontinuation rates were 67.5 %. The mortality in confirmed cases without cirrhosis was 4.10% and 32.1% in cirrhotic patients. The factors associated with the development of cirrhosis were genotype 1 (p = 0.0015) and bilirubin > 1.3 mg % (p = 0.0017). Factors associated with mortality were age over 35 years, abandon treatment, diabetes, insulin use, AST> 60 IU, ALT> 60 IU, high total bilirubin, extended TAP, INR high, low albumin, treatment withdrawal, cirrhosis and hepatocarcinoma. The occurrence of diabetes mellitus increased mortality of patients with hepatitis C in 6 times. Variables associated with the diagnosis of cirrhosis by us were blood donor (odds ratio 0.24, p = 0.044) and professional athlete (odds ratio 0.18, p = 0.35). It is reasonable to consider a revaluation in screening models for CHC currently proposed. The condition of cirrhosis and diabetes modifies the clinical course of patients with chronical hepatitis C, making it a disease more mortality. However, being a blood donor or professional athlete is a protective factor that reduces the risk of cirrhosis, independent of alcohol consumption. Public policies to better efficient access, hosting and resolution are needed for this population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Amphotericin B (AmB), an antifungal agent that presents a broad spectrum of activity, remains the gold standard in the antifungal therapy. However, sometimes the high level of toxicity forbids its clinical use. The aim of this work was to evaluate and compare the efficacy and toxicity in vitro of Fungizon™ (AmB-D) and two new different AmB formulations. Methods: three products were studied: Fungizon™, and two Fungizon™ /Lipofundin™ admixtures, which were diluted through two methods: in the first one, Fungizon™ was previously diluted with water for injection and then, in Lipofundin™ (AmB-DAL); the second method consisted of a primary dilution of AmB-D as a powder in the referred emulsion (AmB-DL). For the in vitro assay, two cell models were used: Red Blood Cells (RBC) from human donors and Candida tropicallis (Ct). The in vitro evaluation (K+ leakage, hemoglobin leakage and cell survival rate-CSR) was performed at four AmB concentrations (from 50 to 0.05mg.L-1). Results: The results showed that the action of AmB was not only concentration dependent, but also cellular type and vehicle kind dependent. At AmB concentrations of 50 mg.L-1, although the hemoglobin leakage for AmB-D was almost complete (99.51), for AmB-DAL and AmB-DL this value tended to zero. The p = 0.000 showed that AmB-D was significantly more hemolytic. Conclusion: The Fungizon™- Lipofundin™ admixtures seem to be the more valuable AmB carrier systems due to their best therapeutic index presented