3 resultados para Flexor digitorum superficialis, flexor digitorum profundus, mano,tendon

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human aging is physiological process causes alterations in several systems of the organism. In the musculoskeletal system, a main change is the decreased muscle strength, that in the lower extremity, compromises the ability to respond quickly with enough strength to prevent falls, causing alterations in postural balance. Currently, many researchers have study the human frailty, defined as a multifactorial syndrome, with excess of vulnerability to stressors, reducing ability in maintaining or regulating homeostasis. Its characteristics are directly related to physical function. Aim: To analyze muscle performance and postural balance in frail and pre-frail elderly women, and to compare them according with the frailty phenotypes criteria proposed by Fried 2001. Method: 39 frail elderly women living in the community, aged 65 years and older, were assessed muscle performance of lower extremity using isokinetic dynamometer and postural balance using Berg s balance scale and computerized baropodometry. Results: There was significant difference in plantar flexor, knee flexor and knee extensor strength, in anteroposterior (AP) oscillation with eyes open and on Berg s scores between groups. A weak correlation was observed between strength and balance. Conclusion: The results suggest that the frail elderly present worse muscle performance in lower extremity and worse postural balance compared to the pre-frail elderly. There were correlations between muscle performance and balance impairments in these elderly, but several variables are also involved in maintaining postural balance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Pilates Method is a modality of exercise that has been growing in recent decades, but few researches has been conducted with elderly and little is known about its benefits in this population. Objective: To evaluate the effect of a program of Mat Pilates exercises in muscle performance and postural balance in elderly women. Materials and Method: This is a randomized controlled trial that evaluated the muscle performance (isokinetic dynamometer Biodex System 3 Pro®) and postural balance (Balance Master System®) of 33 women aged 65-80 years. The experimental group (EG) participated of a 12-week program of Mat Pilates exercises with two weekly sessions. Data normality was verified by the Shapiro - Wilk test and were adopted p value < 0.05 as significance level. Results: There were no differences between groups after training. However, the EG showed an increase in the values of extension and flexion average power to 60 ° / s after training (32.19 W to 37.04 W and 14.48 W to 17.56 W, respectively). Conclusion: The proposed exercise program was not effective in the total work and average power of flexor and extensor of the knee, as well as static and dynamic balance of participants