4 resultados para Evaluation protocol
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The reports of adverse events date from 1990 up to the present day. Conceptually, these adverse events are unintentional injuries unrelated to the underlying disease, causing measurable lesions in patients, extending the period of hospitalization, or leading to death. These issues require discussions with regard to patient safety, improved quality of service, and preventing medical errors. In the Intensive Care Units, this concern is greater because these are sectors of intensive care to individuals with hemodynamic changes and imminent risk of death. Therefore, it is essential to conduct evaluation processes to investigate aspects of quality of nursing care and patient safety in these spaces. For that reason, we aimed to propose the Evaluation protocol of nursing care and patient safety in Intensive Care Units. For its achievement, we needed to: 1) analyze the evolution of the patient safety concept used in scientific productions, under Rodgers evolutionary concept; 2) identify the necessary items to build the evaluation protocol of nursing care and patient safety in the Intensive Care Unit, from the available evidence in literature; 3) construct an instrument for content validation of the evaluation protocol of nursing care and patient safety in the Intensive Care Unit; and 4) describe and evaluate the appropriateness of the content for an evaluation protocol of nursing care and patient safety in the Intensive Care Unit. This is a methodological study for the content validation of the abovementioned protocol. To meet the first three specific objectives, we used the integrative literature review in Theses Database of the Coordination for the Improvement of Higher Education Personnel and the portal of the Collaborating Centre for Quality of Care and Patient Safety. The fourth specific objective happened through the participation of judges, located from the Lattes curricula, in the content validation process developed in two stages: Delphi 1 and Delphi 2. As instrument, we used the electronic form of Google docs. We present in tables the answers from the evaluation instruments by Delphi consensus and Content Validity Index (CVI) of the entire protocol. We summarized the results in articles entitled Analysis of the patient safety concept: Rodgers evolutionary concept ; Scientific evidence regarding patient safety in the Intensive Care Unit ; Technological device for the content validation process: experience report ; and Evaluation protocol of nursing care and patient safety in Intensive Care Units. The Embodied Opinion of the Research Ethics Committee of the Universidade Federal do Rio Grande do Norte, No. 461,246, under CAAE 19586813.2.0000.5537, approved the study. Thus, we conclude the protocol valid in its content, constituting an important tool for evaluating the quality of nursing care and patient safety in Intensive Care Units
Resumo:
Objective: to investigate the immediate effect of the vibrating platform on the neuromuscular performance of the quadriceps femoris and on the postural oscillation of subjects submitted to Anterior Cruciate Ligament (ACL) reconstruction. Materials and methods: this study is a randomized and blind clinical trial. Forty-four male volunteers (average age of 27,4 ±6,2 IMC of 26,85± 3,8 Kg/m² and post surgery timeframe of 17± 1,4 weeks) were randomized into two groups: OFF platform (n=22, protocol of exercise over the vibrating platform off) and ON platform (n=22 protocol of exercise over the vibrating platform on, 50Hz frequency and 4mm of amplitude). All volunteers were submitted to assessment the isokinetic evaluation of the quadriceps femoris (isometric and isokinetic at 60°/s) and of the electromyography activity of the muscles Vasto Lateralis (VL) and Vasto Medialis (VM), besides the postural oscillation (baropodometry) in two distinct moments: before and immediately after the intervention protocol. The data was analyzed through the SPSS 20.0 software, with a 5% significance level. To verify the homogeneity of the groups it was used an ANOVA one way, and a ANOVA mixed model to compare the intra and inter groups. Results: it was observed differences between the pre and the post, to latero lateral velocity, isometric torque peak and total work in comparison with intragroup. However, it wasn’t verified any difference in comparing the intergroup in the preevaluation and in the post-evaluation protocol over the vibrating platform. Conclusion: the use of the vibrating platform doesn’t change as an immediate manner the isokinetic performance of the quadriceps femoris, the electromyography activity of the VL and the VM, also doesn’t interfere with the postural oscillation of individuals that were submitted to the ACL reconstruction.
Resumo:
PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.
Resumo:
PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.