12 resultados para Enhanced recovery after surgery
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
After the decline of production from natural energy of the reservoir, the methods of enhanced oil recovery, which methods result from the application of special processes such as chemical injection, miscible gases, thermal and others can be applied. The advanced recovery method with alternating - CO2 injection WAG uses the injection of water and gas, normally miscible that will come in contact with the stock oil. In Brazil with the discovery of pre-salt layer that gas gained prominence. The amount of CO2 present in the oil produced in the pre-salt layer, as well as some reservoirs is one of the challenges to be overcome in relation to sustainable production once this gas needs to be processed in some way. Many targets for CO2 are proposed by researchers to describe some alternatives to the use of CO2 gas produced such as enhanced recovery, storage depleted fields, salt caverns storage and marketing of CO2 even in plants. The largest oil discoveries in Brazil have recently been made by Petrobras in the pre -salt layer located between the states of Santa Catarina and Espírito Santo, where he met large volumes of light oil with a density of approximately 28 ° API, low acidity and low sulfur content. This oil that has a large amount of dissolved CO2 and thus a pioneering solution for the fate of this gas comes with an advanced recovery. The objective of this research is to analyze which parameters had the greatest influence on the enhanced recovery process. The simulations were performed using the "GEM" module of the Computer Modelling Group, with the aim of studying the advanced recovery method in question. For this work, semi - synthetic models were used with reservoir and fluid data that can be extrapolated to practical situations in the Brazilian Northeast. The results showed the influence of the alternating injection of water and gas on the recovery factor and flow rate of oil production process, when compared to primary recovery and continuous water injection or continuous gas injection
Resumo:
Petroleum is a complex combination of various classes of hydrocarbons, with paraffinic, naphtenic and aromatic compounds being those more commonly found in its composition. The recent changes in the world scenario, the large reserves of heavy oils and also the lack of new discoveries of large petroleum fields are indications that, in the near future, the oil recovery by conventional methods will be limited. In order to increase the efficiency of the extraction process, enhanced recovery methods are cited in applications where conventional techniques have proven to be little effective. The injection of surfactant solutions as an enhanced recovery method is advantageous in that surfactants are able to reduce the interfacial tensions between water and oil, thus augmenting the displacement efficiency and, as a consequence, increasing the recovery factor. This work aims to investigate the effects of some parameters that influence the surfactant behavior in solution, namely the type of surfactant, the critical micelle concentration (CMC) and the surface and interface tensions between fluids. Seawater solutions containing the surfactants PAN, PHN and PJN have been prepared for presenting lower interfacial tensions with petroleum and higher stability under increasing temperature and salinity. They were examined in an experimental apparatus designed to assess the recovery factor. Botucatu (Brazil) sandstone plug samples were submitted to assay steps comprising saturation with seawater and petroleum, conventional recovery with seawater and enhanced recovery with surfactant solutions. The plugs had porosity between 29.6 and 32.0%, with average effective permeability to water of 83 mD. The PJN surfactant, at a concentration 1000% above CMC in water, had a higher recovery factor, causing the original oil in place to be recovered by an extra 20.97%, after conventional recovery with seawater
Resumo:
Morbidly obese patients present an increase in heart rate, blood pressure and perceived exertion besides lower walking ability compared to normal weight people. However, little is known about how these variables are presented after bariatric surgery. Moreover, despite the distance walked during the six-minute walk (6MWT) improve after surgery is not well established if the level of physical activity influences this improvement. Objective: To evaluate cardiovascular performance, perceived effort, ability of walking and physical activity level of patients with morbid obesity before and after bariatric surgery. Methods: The cardiovascular performance, perception of effort, the ability to walk and level of physical activity were assessed in 22 patients before (BMI = 50.4 kg/m2) and after (BMI = 34.8 kg/m2) bariatric surgery through the 6MWT. The heart rate, blood pressure and perceived exertion were assessed at rest, at the end of the 6MWT and in the second minute post-test (HR recovery). The ability to walk was measured by total distance walked at the end of the test while the level of physical activity was estimated by applying the Baecke questionnaire, analyzing domains occupation, leisure and locomotion and leisure and physical activity. Results: The HR at rest and recovery decreased significantly (91.2 ± 15.8 bpm vs. 71.9 ± 9.8 bpm, 99.5 ± 15.3 bpm vs 82.5 ± 11.1 bpm, respectively), as well as all the arterial pressure and perceived exertion after surgery. The distance achieved by the patients increased by 58.4 m (p = 0.001) postoperatively. Time postoperatively had correlation with the percentage of excess weight lost (r = 0.48, p = 0.02), BMI (r =- 0.68, p = 0.001) and the Baecke (r = 0.52, p = 0.01) which did not happen with the distance walked (r = 0.37, p = 0.09). Despite weight loss, patients showed no difference in the level of physical activity in any of the areas before and after surgery. Conclusion: The cardiovascular performance, the perception of effort and ability to walk seem to improve after bariatric surgery. However, despite improvement in the ability to walk by the distance achieved in the 6MWT after weight loss, this is not reflected in an increase in physical activity level of obese patients after surgery
Resumo:
The objective of this randomized, blind and prospective clinical trial was to compare the pain, the edema, the mandibular movements, the masticatory efficiency and life quality, in the first 60 days after surgery using 2 different clinical protocols for myofunctional recovery, in patients who underwent orthognathic surgery. A sample of 19 patients was used and divided into 2 groups. The control group (CG) consisted of 10 patients who had postoperative rehabilitation guided by a standard protocol, conducted by the Service of Surgery and Traumatology Oral and Maxillofacial. In other hand, the experimental group (EC) totaled 9 patients who received the speech therapy rehabilitation protocol specialized, by professionals in the area. The variables pain, edema and mandibular movements were analyzed during 48h, 96h, 7 days, 14 days, 30 and 60 days post-surgery. The masticatory efficiency and the quality of life were classified with 60 days after surgery . The data were submitted an analysis of variance, Student's t-test and Fisher's independence, at the level of 5% probability. It was identified that patients of GE have benefited in the first 14 days(p<0,001), as they have had reported less pain than those in the CG. Significant statistics differences between groups for pain parameters (after 14 days) (p=0,065), edema(p=0,063), mandibular movements(p=0,068), masticatory efficiency(p=0,630) and the impact on quality of life (p=0,813) were not observed on this study. The speech therapy protocol for myofunctional recovery (EG), although it has not obtained statistical results superiors than the CG in the general context, presents itself as a viable alternative to conventional therapy assumed by many maxillofacial surgeons, allowing the surgeon to optimize time with patients in the period postoperatively.
Resumo:
After the decline of production from natural energy of the reservoir, the methods of enhanced oil recovery, which methods result from the application of special processes such as chemical injection, miscible gases, thermal and others can be applied. The advanced recovery method with alternating - CO2 injection WAG uses the injection of water and gas, normally miscible that will come in contact with the stock oil. In Brazil with the discovery of pre-salt layer that gas gained prominence. The amount of CO2 present in the oil produced in the pre-salt layer, as well as some reservoirs is one of the challenges to be overcome in relation to sustainable production once this gas needs to be processed in some way. Many targets for CO2 are proposed by researchers to describe some alternatives to the use of CO2 gas produced such as enhanced recovery, storage depleted fields, salt caverns storage and marketing of CO2 even in plants. The largest oil discoveries in Brazil have recently been made by Petrobras in the pre -salt layer located between the states of Santa Catarina and Espírito Santo, where he met large volumes of light oil with a density of approximately 28 ° API, low acidity and low sulfur content. This oil that has a large amount of dissolved CO2 and thus a pioneering solution for the fate of this gas comes with an advanced recovery. The objective of this research is to analyze which parameters had the greatest influence on the enhanced recovery process. The simulations were performed using the "GEM" module of the Computer Modelling Group, with the aim of studying the advanced recovery method in question. For this work, semi - synthetic models were used with reservoir and fluid data that can be extrapolated to practical situations in the Brazilian Northeast. The results showed the influence of the alternating injection of water and gas on the recovery factor and flow rate of oil production process, when compared to primary recovery and continuous water injection or continuous gas injection
Resumo:
Introduction: The emergence of High Active Antiretroviral Therapy (HAART) increase the life expectancy of the persons living with HIV/AIDS (PLHIV), therefore the prolonged use cause metabolic implications and influences on body fat distribution and increase the cardiovascular diseases prevalence. Aims: Evaluate the effect of resistance training on heart rate variability, biochemical parameters and somatotype on PLHIV. Methods: Participated this study seven sedentary men, with age above 25 years old, living with HIV/AIDS, under HAART use. Were submitted a 16 week intervention with resistance training. Evaluated the heart rate variability, biochemical parameters and somatotype, before, after 8 weeks and 16 weeks, all in paired form. It was found the data normality by Shapiro-Wilk test and conducted the Anova one way combined with Tukey post hoc to samples in each evaluate moment, adopting significance level p<0,05. Also were calculated percentage change deltas. For somatotype was used the somatotype spatial distance (DES), obeying the significance value DES≥1. Results: Was found significance differences only in variable final heart rate delta 60s (p=0,01), however, is not showed changes on heart rate variability, biochemical parameters and somatotype components. Conclusion: 16 weeks of resistance training showed improvement on heart rate recovery after submaximal effort and, despite is not enough to produce significance differences on biochemical parameters and somatotype components, could be realize improvement on average value of fasting glucose and lipid profile, as well as reducing the endomorphic component
Resumo:
The human voice is an important communication tool and any disorder of the voice can have profound implications for social and professional life of an individual. Techniques of digital signal processing have been used by acoustic analysis of vocal disorders caused by pathologies in the larynx, due to its simplicity and noninvasive nature. This work deals with the acoustic analysis of voice signals affected by pathologies in the larynx, specifically, edema, and nodules on the vocal folds. The purpose of this work is to develop a classification system of voices to help pre-diagnosis of pathologies in the larynx, as well as monitoring pharmacological treatments and after surgery. Linear Prediction Coefficients (LPC), Mel Frequency cepstral coefficients (MFCC) and the coefficients obtained through the Wavelet Packet Transform (WPT) are applied to extract relevant characteristics of the voice signal. For the classification task is used the Support Vector Machine (SVM), which aims to build optimal hyperplanes that maximize the margin of separation between the classes involved. The hyperplane generated is determined by the support vectors, which are subsets of points in these classes. According to the database used in this work, the results showed a good performance, with a hit rate of 98.46% for classification of normal and pathological voices in general, and 98.75% in the classification of diseases together: edema and nodules
Resumo:
Petroleum exists in the nature in certain underground formations where it is adsorbed into the rocks pores. For the conventional recovery methods usually only 30% of the oil is extracted and this can be credited, basically, to three aspects: high viscosity of the oil, geology of the formation and high interfacial tensions between the reservoir s fluids. The enhanced recovery methods use the injection of a fluid or fluids mixture in a reservoir to act in points where the conventional process didn't reach the recovery rates. Microemulsion flooding, considered an enhanced method, has the purpose to desorb the oil from the rock formation and to attain an efficient displacement of the oil emulsion. With this in mind, this work was accomplished with two main objectives: the study of the parameters effect that influence a microemulsified system (surfactant and cosurfactant types, C/S rate and salinity) and the evaluation of displacement efficiency with the microemulsions that showed stability in the rich aqueous area. For the analyzed parameters it was chose the microemulsions composition used in the recovery stage: 25% water, 5% kerosene, 46.7% of butanol as cosurfactant and 23.3% of BC or SCO cosurfactant. The core plugs of Assu and Botucatu sandstones were appraised in porosity and permeability tests and then submitted to the steps of saturation with seawater and oil, conventional recovery with water and enhanced recovery with the selected microemulsions. The Botucatu sandstone presented better recovery parameters, and the microemulsion composed with BS surfactant had larger recovery efficiency (26.88%)
Resumo:
Among the waste generated in the petrochemical industry water associated with oil production is the most important. It is considered one of the great challenges due to the presence of considered toxic chemicals present in this composition. The presence of these substances difficult to reuse the water associated with the enhanced recovery processes, so that prior to their reuse or disposal, treatment is necessary. This paper aimed to study the removal efficiency of chemical species: Ba2+, Ni2+, Cd2+, Cu2+, Cr3+, Sr2+ and Zn2+, present in the composition of the water associated with oil production by electrocoagulation. The evaluation of removal of these chemical species was performed by laboratory tests using electrochemical batch reactors and continuous flow. Initial tests were performed with electrocoagulation of synthetic wastewater in batch reactor using iron electrode. Results of removal of Zn2+ and Ni2+ were 78 % and 59 % respectively. While the percentage of removed Ba2+ was 19 % by 30 minutes of treatment and by applying current of 1.10 A. The tests were performed on effluent batch reactor applying the electrochemical technique with stainless steel electrodes 304, the objective was to remove part of the dispersed oil and also of organic compounds in the effluent. Under the experimental conditions used, the maximum result was obtained TOG was 60 % and TOC was approximately 50 % compared to the initial concentration. In the experiments carried out in continuous reactor, with effluent semisynthetic, have been used electrodes of iron and aluminum and the results were 100 % removal of Cd2+, Cu2+, Cr3+ and Zn2+ and 77 % of Sr2+. These percentages were only attainable through the use of the iron electrode. However, when the electrode was replaced by aluminum, there was a reduction in the percentage of removal to 65 %, using the same flow rate and current. Therefore according to the results obtained using the iron electrode was more effective in removing these metals and the conditions of lower current and lower flow rate was satisfactory, as observed in the experimental design adopted
Resumo:
Muscle fatigue is a phenomenon that promotes physiological and biomechanical disorders and their changes in healthy subjects have been widely studied and have significant importance for care in preventing injuries, but we do not have many information about its effects in patients after ACL reconstruction. Thus, this study is to analyze the effects of fatigue on neuromuscular behavior of quadriceps after ACL reconstruction. To reach this objective, participants were forty men, twenty healthy (26,90 ± 6,29 years) and twenty after ACL reconstruction (29,75 ± 7,01 years) with a graft of semitendinosus and gracilis tendons, between four to six months after surgery. At first, there was an assessment of joint position sense (JPS) at the isokinetic dynamometer at a speed of 5°/s and target angle of 45° to analyze the absolute error of JPS. Next, we applied the a muscle fatigue protocol, running 100 repetitions of isokinetic knee flexion-extension at 90°/s. Concurrently with this protocol, there was the assessment of muscle performance, as the peak torque (PT) and fatigue index, and electromyographic activity (RMS and median frequency). Finally, we repeated the assessment of JPS. The statistical analysis showed that patients after ACL reconstruction have, even under normal conditions, the amended JPS compared with healthy subjects and that after fatigue, both have disturbances in the JPS, but this alteration is significantly exacerbated in patients after ACL reconstruction. About muscle performance, we could notice that these patients have a lower PT, although there are no differences between the dynamometric and EMG fatigue index. These findings show the necessity about the cares of pacients with ACL reconstruction in respect of the risks of articulate instability and overload in ligamentar graft
Resumo:
Many studies have been made to understand the process of tissular cicatrization, as well as the possible effects of laser therapy in the wound healing. However, the influence of low frequency laser irradiation in the repairing process is not completely understood. Our study has the purpose to assess clinically the effect of postoperative irradiation of the low frequency laser in humans, and the gingival repairing process postgingivoplasty performed with the extern bevel technique. Twenty-four patients with inflammatory gingival hyperplasia were enrolled in this study, which did not reduce with basic periodontal procedures, and patients with melanin pigmentation, with esthetic indications. After surgery the test group, randomly selected by a drawing, received laser application with energy density of 4 J/cm2, immediately after surgery and each 48 hours, during a week, with a total of 4 sections. The control group did not receive irradiation. The visual clinical analyses were performed by a single blind examiner, in the 2nd, 4th, 6th, 8th, 15th and 21st days post surgery. For statistic analyses of the data was used a Q-square test. Concerning the color, the results showed a better wound healing during days 6 to 8. when assessed the degree of progress of surgical wound, the results showed that the test group had a better cicatrization compared with the control group in the 2nd, 6th, 8th and 15th days post surgery, and at the 21st day both groups had the same results. Our results confirm that the laser had clinical influence in the repairing process after gingivoplasty surgery during days 2 to 15 post surgery
Resumo:
Most cochlear implant (CI) users, who suffer from post lingual hearing loss, are able to perceive sounds and comprehend speech after the implant. The prediction of maximal benefit over time, with the use of CI, can be useful for counseling patients about their expectations in using the new device. The measurement of satisfaction should be of primary interest in medical intervention, as the results may be used for intervention feedback. The purpose of this study is to analyze auditory performance of CI over time, as well as to evaluate users‟ satisfaction. Therefore two types of study designs were employed: a) retrospective cohort study with the analysis of medical records from 59 subjects about auditory performance before and after surgery. Results were submitted to the Kaplan -Meier estimator of cumulative probability and compared to prognostic factors of auditory performance using the logrank test. b) A sectional study design was conducted to evaluate the satisfaction of 51 subjects. The instrument consists of two specific questionnaires: Satisfaction with Amplification in Daily Life SADL and International Outcome Inventory Cochlear Implant IOI- CI. Results show statistical significant differences (p<0,001) in auditory performance before and after CI. The majority obtained satisfactory results of CI use during the first six months. Logrank tests does not indicate significant correlation between the analyzed covariates and the time in which adequate speech perception occurs. SADL e IOI-CI questionnaires indicate that most of the CI users are satisfied with their devices. The SADL detected a 27, 5% insatisfaction amongst CI users in relation to services and costs involved with the CI. The results of the IOI show 4% of insatisfaction with the use of CI and the social environment. In conclusion CI is capable to rehabilitate social auditory function in a short period of time and CI users demonstrate satisfaction with auditory, social and psychological gain offered through CI device