16 resultados para Energy efficiency

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sustainability in buildings, while reducing the impact on the environment, contributes to the promotion of social welfare, to increase the health and productivity of occupants. The search for a way of build that meets the aspirations and development of humanity without, however, represent degradation of the environment, has become the great challenge of contemporary architecture. It is considered that the incorporation of principles that provide a sustainable building with careful choices of design solutions contribute to a better economic and thermal performance of the building, as well as functional and psychological comfort to its users. Based on this general understanding, this paper presents an architecture project aimed to health care whose the solutions adopted follow carefully the relevant legislation and sets his sights on the theme of sustainability. The methodology began with studies on the themes of verification service of deaths, sustainability and those application in construction developed through research in academic studies and analysis of architectural projects, using them like reference for the solutions adopted. Within the project analysis was performed a visit to the verification service of deaths in the city of Palmas in Tocantins, subsidizing information that, plus the relevant legislation, led to functional programming and pre-dimensional of the building to be designed. The result of this programming environments were individual records with information from environmental restrictions, space required for the development of activities, desirable flow and sustainability strategies, that can be considered as the first product of relevance of the professional master's degree. Finally we have outlined the basic design architecture of a Verification Service of Death SVO/RN (in portuguese), whose process of projecting defined as a guiding line of work four points: the use of bioclimatic architecture as the main feature projectual, the use of resources would provide minimal harm to the environment, the use of modulation and structure to the building as a form of rationalization and finally the search for solutions that ensure environmental and psychological comfort to users. Importantly to highlight that, besides owning a rare theme in literature that refers to architectural projects, the whole project was drawn up with foundations in projective criteria that contribute to environmental sustainability, with emphasis on thermal performance, energy efficiency and reuse of rainwater

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The employment of flexibility in the design of façades makes them adaptable to adverse weather conditions, resulting in both minimization of environmental discomfort and improvement of energy efficiency. The present study highlights the potential of flexible façades as a resource to reduce rigidity and form repetition, which are usually employed in condominiums of standardized houses; as such, the work presented herein contributes to field of study of architectural projects strategies for adapting and integrating buildings within the local climate context. Two façade options were designed using as reference the bionics and the kinetics, as well as their applications to architectural constructions. This resulted in two lightweight and dynamic structures, which cater to constraints of comfort through combinations of movements, which control the impact of solar radiation and of cooling in the environment. The efficacy and technical functionality of the façades were tested with comfort analysis and graphic computation software, as well as with physical models. Thus, the current research contributes to the improvement of architectural solutions aimed at using passive energy strategies in order to offer both better quality for the users and for the sustainability of the planet

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis describes the theoretical, methodological and programmatic proposal for a multifamily residential building located in the urban expansion area of Parnamirim/RN, inserted in the program Minha Casa Minha Vida and level of energy efficiency "A", as the RegulamentoTécnico de Qualidade (RTQ-R/INMETRO) for residential buildings. The development project initially consists of procedures as the study of theoretical, architectural programming and cases studies. With the delimitation of a field solution, situated between the reference and the context, proposals are studied to determine the solution and architectural detailing of the proposal. The architectural program was built based on the method of Problem Seeking (Peña and Parshall, 2001) and research has highlighted aspects of reducing the environmental impact and of the program Minha Casa Minha Vida , among others. The design process was characterized by the incorporation of aspects reviewed and programmed, seeking them compatible and have an economically viable building, socio-spatial quality and energy efficient. The results show that it is possible to obtain a building that meets the constraints of the program that provides housing and energy efficiency level A - and many other environmental qualities and constructive, particularly through architectural design

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this dissertation is the architectural project of the ambulatory complex of the Federal University of Pará in Belém. It is a health care establishment whose focus is sustainability, energy efficiency and humanization. This design went through the application of architectural concepts, the study of references (theorical and empirical ones), planning, examining the terrain and its conditions and the preliminay design and resulted in a preliminary architecture blueprint. The empirical research is based on the main building of the Hospital Universitário João de Barros Barreto in Belém, Hospital Sarah Kubitschek of Fortaleza (Architect João Filgueiras de Lima - Lelé) and Hospital e Maternity São Luiz of São Paulo (Architect Siegbert Zanettini). Part of the planning is based on the method "Problem Seeking of Pena and Parshal (2001)". During the development process I sought to incorporate sustainability criterias, energy efficiency and humanization. In relation to sustainability the dissertation focuses on the utilization of rainwater for non-potable usage

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The goal of the research was to investigate the energy performance of residential vertical buildings envelope in the hot and humid climate of Natal, capital of Rio Grande do Norte, based in the Technical Regulation of Quality for Energy Efficiency Level in Residential Buildings (RTQ -R), launched in 2010. The study pretends to contribute to the development of design strategies appropriate to the specific local climate and the increasing of energy efficiency level of the envelope. The methodological procedures included the survey in 22 (twenty two) residential buildings, the formulation of representative prototypes based on typological and constructives characters researched and the classification of the level of energy efficiency in the envelopment of these prototypes, using as a tool the prescriptive method of the RTQ-R and the parametric analyzes from assigning different values of the following variables: shape of the pavement type; distribution of housing compartments; orientation of the building; area and shading of openings; thermal transmittance, and solar absorptance of opaque materials of the frontage in order to evaluate the influence of these on the envelopment performance. The main results accomplished with this work includes the qualification of vertical residential buildings in Natal/RN; the verification of the adequacy of these buildings to local climate based from the diagnosis of the thermal energy of the envelopment performance, the identification of variables with more significant influence on the prescriptive methodology of RTQ-R and design solutions more favorable to obtain higher levels energy efficiency by this method. Finally, it was verified, that some of these solutions proved contradictory in relation to the recommendations contained in the theoretical approaches regarding environmental comfort in hot and humid weather, which indicates the need for improvement of the prescriptive method RTQ-R and further research on efficient design solutions

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thermoelectric energy conversion can be performed directly on generators without moving parts, using the principle of SEEBECK effect, obtained in junctions of drivers' thermocouples and most recently in semiconductor junctions type p-n which have increased efficiency of conversion. When termogenerators are exposed to the temperature difference (thermal gradient) eletromotriz a force is generated inducing the appearance of an electric current in the circuit. Thus, it is possible to convert the heat of combustion of a gas through a burner in power, being a thermoelectric generator. The development of infrared burners, using porous ceramic plate, is possible to improve the efficiency of heating, and reduce harmful emissions such as CO, CO2, NOx, etc.. In recent years the meliorate of thermoelectric modules semiconductor (TEG's) has stimulated the development of devices generating and recovery of thermal irreversibility of thermal machines and processes, improving energy efficiency and exergy these systems, especially processes that enable the cogeneration of energy. This work is based on the construction and evaluation of a prototype in a pilot scale, for energy generation to specific applications. The unit uses a fuel gas (LPG) as a primary energy source. The prototype consists of a porous plate burner infrared, an adapter to the module generator, a set of semiconductor modules purchased from Hi-Z Inc. and a heat exchanger to be used as cold source. The prototype was mounted on a test bench, using a system of acquisition of temperature, a system of application of load and instrumentation to assess its functioning and performance. The prototype had an efficiency of chemical conversion of 0.31% for electrical and heat recovery for cogeneration of about 33.2%, resulting in an overall efficiency of 33.51%. The efficiency of energy exergy next shows that the use of primary energy to useful fuel was satisfactory, although the proposed mechanism has also has a low performance due to underuse of the area heated by the small number of modules, as well as a thermal gradient below the ideal informed by the manufacturer, and other factors. The test methodology adopted proved to be suitable for evaluating the prototype

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of wireless sensor networks for control and monitoring functions has created a vibrant investigation scenario, covering since communication aspects to issues related with energy efficiency. When source sensors are endowed with cameras for visual monitoring, a new scope of challenges is raised, as transmission and monitoring requirements are considerably changed. Particularly, visual sensors collect data following a directional sensing model, altering the meaning of concepts as vicinity and redundancy but allowing the differentiation of source nodes by their sensing relevancies for the application. In such context, we propose the combined use of two differentiation strategies as a novel QoS parameter, exploring the sensing relevancies of source nodes and DWT image coding. This innovative approach supports a new scope of optimizations to improve the performance of visual sensor networks at the cost of a small reduction on the overall monitoring quality of the application. Besides definition of a new concept of relevance and the proposition of mechanisms to support its practical exploitation, we propose five different optimizations in the way images are transmitted in wireless visual sensor networks, aiming at energy saving, transmission with low delay and error recovery. Putting all these together, the proposed innovative differentiation strategies and the related optimizations open a relevant research trend, where the application monitoring requirements are used to guide a more efficient operation of sensor networks

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of wireless sensor and actuator networks in industry has been increasing past few years, bringing multiple benefits compared to wired systems, like network flexibility and manageability. Such networks consists of a possibly large number of small and autonomous sensor and actuator devices with wireless communication capabilities. The data collected by sensors are sent directly or through intermediary nodes along the network to a base station called sink node. The data routing in this environment is an essential matter since it is strictly bounded to the energy efficiency, thus the network lifetime. This work investigates the application of a routing technique based on Reinforcement Learning s Q-Learning algorithm to a wireless sensor network by using an NS-2 simulated environment. Several metrics like energy consumption, data packet delivery rates and delays are used to validate de proposal comparing it with another solutions existing in the literature

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the State of Rio Grande do Norte potteries are distributed in several counties in the four meso, which are: West Potiguar, Center Potiguar, Agreste Potiguar and East Portiguar. The ceramics, mostly, are responsible for products used in construction as bricks, tiles and white brick and wood used as fuel. This paper had a primary focus in the region of Seridó. The furnaces in this region, used to manufacture bricks are configured Caieira and Valt, in most of them using principles rustic, usually operated in an empirical way, using principles of control rather primitive, predominantly visual control. The focus of this study was to analyze the differences in the thermophysical, mechanical and geometric characteristics of bricks produced by Caieira and vault furnaces, using the NBR 15720 and the evaluation of energy efficiency in both furnaces. Thermophysical characteristics were analyzed through tests to determine the water absorption obtained from the difference between dry mass and wet mass of the sample and analysis of the thermal gradient, the mechanical characteristics from determination of the compressive strength of ceramic brick popularly known as bricks and also analyzed the geometrical characteristics of the bricks in order to verify the homogeneity of manufacturing. The tests showed that the energy difference of the two furnaces is not considered responsible for a significant difference in the properties of the products