7 resultados para Ellipsoidal Harmonics
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
This work presents a theoretical and numerical analysis for the cascading of frequency selective surfaces, which uses rectangular patches and triangular Koch fractals as elements. Two cascading techniques are used to determine the transmission and reflection characteristics. Frequency selective surfaces includes a large area of Telecommunications and have been widely used due to its low cost, low weight and ability to integrate with others microwaves circuits. They re especially important in several applications, such as airplane, antennas systems, radomes, rockets, missiles, etc.. FSS applications in high frequency ranges have been investigated, as well as applications of cascading structures or multi-layer, and active FSS. Furthermore, the analyses uses the microwave circuit theory, with the Floquet harmonics, it allows to obtain the expressions of the scattering parameters of each structure and also of the composed structure of two or more FSS. In this work, numeric results are presented for the transmission characteristics. Comparisons are made with experimental results and simulated results using the commercial software Ansoft Designer® v3. Finally, some suggestions are presented for future works on this subject
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA
Resumo:
This work describes the experimental implementation of a shunt active power filter applied to a three-phase induction generator. The control strategy of active filter turned to the excitation control of the machine and to decrease the harmonics in the generator output current. Involved the implementation of a digital PWM switching, and was made a comparison of two techniques for obtaining the reference currents. The first technique is based on the synchronous dq reference method and the second on the theory of instantaneous power. The comparison is performed via simulation and experimental results. To obtain the experimental results, was mounted a bench trial and the control and communications needed were implemented using DSP - MS320F2812. The simulation results and experimental data proved the efficiency of the filter to apply, highlighting the technique of instantaneous power
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
This work focuses the geological and geomorphological characterization of the inner shelf in the West Coast of the Rio Grande do Norte state, particularly the reef coral barrier offshore of Maracajaú (Maxaranguape district). If developed without the necessary concerns, tourism and entertainment activities that have been widely increased during the last five years can lead to irreversible environmental damages to the biotic and abiotic ecosystems of the region. Regarding these aspects, it is crucial the realization of a detailed study to envisage the achievement of a self-sustainable development, especially with respect to the possibilities of a rational usage of the region. This is the aim of this manuscript, which consisted of an initial stage of digital modeling of the terrain with basis on digitalization and vectorization of the Nautical map number 803 (Naval Service of Brazil, 1971). Information obtained in this phase was improved with the digital processing of small format aerial photos acquired from six flights, which were integrated to form a photomosaic of the area. The refined maps produced with the data from Nautical and aerial photo-interpretations aided to locate 9 bathymetric profiles, which provided information about the sea floor relief of the whole area. This later aided in the choosing of areas to bottom sampling that, in its turn, helped to characterize sediments present in floor of the inner shelf. Sixty-four samples collected during this work were studied by granulometrical and chemical analysis; with the later one developed in order to measure carbonate and organic matter contents. Forty-two of these samples showed carbonate content higher than 80% and organic matter in the range of 0.58% to 24.06%. With respect to grain size, these samples are in the interval between fine- to mid-grained sands. Sands with grain sizes higher than this one are also composed by carbonate carapaces such as pale yellow to red rhodolites with ellipsoidal and spheroidal shapes. During determination of the submerse features, the small format aerial photos demonstrated to be a useful methodology to aid the delineation of the sea floor topography through shallow deep waters. The bathymetry, for its turn, revealed several features at the bottom of the platform, in which the most conspicuous are undulations and morphological details of the São Roque Channel. Examination of bottom, aside from sand, yielded the identification of bivalves, ostracods, fragments of bryozoans, spikes of sponges, spines of echinoderms, operculum of gastropods and foraminifers. From the above it is concluded that the multi-methodological approach developed in this study worked efficiently, permitting the geomorphological and environmental characterization of the inner shelf of the North Maracajaú
Resumo:
Recognized for his relevant writing for the cello, Silvio Ferraz wrote , in 2012, Segundo Responsório for cello solo and chamber group which followed Responsório ao Vento , a version of the same piece for solo cello . The work is characterized by the idea of continuity of sound moving through different textures , timbres , dynamics and musical gestures. The composer uses extended techniques, such as large sections in sul tasto playing three strings simultaneously, trills of natural harmonics , muffled trills with natural harmonics , col legno batuto , different types of glissando and simultaneous sounds of harmonic and non harmonic notes corroborate to a wealth of sounds and layers that create different textures. This article investigates the relationship of the composer with the cello, and relates Responsório ao Vento to his other works and studies the influences of the composer addressing technical and interpretive aspects of the piece drawn from performance experiences.