Resumo:

In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The WTP produce many kinds of residue on your treatment stages, but the sludge is the more problematic from the final disposition point view. The actual rate of residue production deriving from technological evolution and the crescent population needs prevents the subtle equilibrium generation between consumption and recycling/reuse, creating problems of pollution resulting from inappropriate management of residues. Thus, is necessary achieve a new equilibrium between the grow from raw materials and energy and the residue generation. This equilibrium should be achieved by technical and economic feasibility of environmental supported models through recycling and reuse. The red ceramic industry stand out in residue absorption question as raw material due their clay mass heterogeneity, constituted by clay minerals and non-clay minerals with wide mineralogical variation, allowing residue inclusion which act like plastic or non-plastic materials, contributing to retain heavy metals contained in residues in the vitreous mass formed during the burning of the ceramic bodies. This work propose the study of the influence of incorporation of 25 wt.% sludge from wastewater treatment plant, according preliminary results, in the mass to produce ceramic bodies. The raw materials was characterized through chemical composition analyses by XRF, mineralogical analyses by XRD, thermal analyses by TG and DTA, Atterberg limits and thermodilatometry. Subsequently was composed the mass with 75 wt.% of clay and 25 wt.% of dried wastewater sludge from UFRN WWTP. Samples with 6,0 x 2,0 x 0,5 cm was produced with unidirectional compacting under pressure of 20MPa and burned in temperatures between 950 and 1,200ºC. After fired, the ceramic bodies have been submitted to physical and mechanical analyses through the measure of firing shrinkage, water absorption, density, apparent porosity and flexural strength; crystallographic analyses through XRD and microstructure analyses by SEM. The technological properties obtained was satisfactory to production of roof tiles with 25 wt.% at 1,200 ºC, but the production of others products at lower temperatures was not feasible

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The WTP produce many kinds of residue on your treatment stages, but the sludge is the more problematic from the final disposition point view. The actual rate of residue production deriving from technological evolution and the crescent population needs prevents the subtle equilibrium generation between consumption and recycling/reuse, creating problems of pollution resulting from inappropriate management of residues. Thus, is necessary achieve a new equilibrium between the grow from raw materials and energy and the residue generation. This equilibrium should be achieved by technical and economic feasibility of environmental supported models through recycling and reuse. The red ceramic industry stand out in residue absorption question as raw material due their clay mass heterogeneity, constituted by clay minerals and non-clay minerals with wide mineralogical variation, allowing residue inclusion which act like plastic or non-plastic materials, contributing to retain heavy metals contained in residues in the vitreous mass formed during the burning of the ceramic bodies. This work propose the study of the influence of incorporation of 25 wt.% sludge from wastewater treatment plant, according preliminary results, in the mass to produce ceramic bodies. The raw materials was characterized through chemical composition analyses by XRF, mineralogical analyses by XRD, thermal analyses by TG and DTA, Atterberg limits and thermodilatometry. Subsequently was composed the mass with 75 wt.% of clay and 25 wt.% of dried wastewater sludge from UFRN WWTP. Samples with 6,0 x 2,0 x 0,5 cm was produced with unidirectional compacting under pressure of 20MPa and burned in temperatures between 950 and 1,200ºC. After fired, the ceramic bodies have been submitted to physical and mechanical analyses through the measure of firing shrinkage, water absorption, density, apparent porosity and flexural strength; crystallographic analyses through XRD and microstructure analyses by SEM. The technological properties obtained was satisfactory to production of roof tiles with 25 wt.% at 1,200 ºC, but the production of others products at lower temperatures was not feasible

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the degradation of real and synthetic wastewater was studied using electrochemical processes such as oxidation via hydroxyl radicals, mediated oxidation via active chlorine and electrocoagulation. The real effluent used was collected in the decanter tank of the Federal University of Rio Grande do Norte (ETE-UFRN) of Effluent Treatment Plant and the other a textile effluent dye Ácido Blue 113 (AB 113) was synthesized in the laboratory. In the electrochemical process, the effects of anode material, current density, the presence and concentration of chloride as well as the active chlorine species on site generated were evaluated. Electrodes of different compositions, Ti/Pt, Ti/Ru0,3Ti0,7O2, BDD, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 were used as anodes. These electrodes were subjected to electroanalytical analysis with the goal of checking how happen the anodic and cathodic processes across the concentrations of NaCl and supporting electrolyte used. The potential of oxygen evolution reaction were also checked. The effect of active chlorine species formed under the process efficiency was evaluated by removing the organic matter in the effluent-ETE UFRN. The wastewater treatment ETE-UFRN using Ti/Pt, DDB and Ti/Ru0,3Ti0,7O2 electrodes was evaluated, obtaining good performances. The electrochemical degradation of effluent-UFRN was able to promote the reduction of the concentration of TOC and COD in all tested anodes. However, Ti/Ru0,3Ti0,7O2 showed a considerable degradation due to active chlorine species generated on site. The results obtained from the electrochemical process in the presence of chloride were more satisfactory than those obtained in the absence. The addition of 0.021 M NaCl resulted in a faster removal of organic matter. Secondly, was prepared and characterized the electrode Ti/TiO2-nanotubes/PbO2 according to what the literature reports, however their preparation was to disk (10 cm diameter) with surface area and higher than that described by the same authors, aiming at application to textile effluent AB 113 dye. SEM images were taken to observe the growth of TiO2 nanotubes and confirm the electrodeposition of PbO2. Atomic Force Microscope was also used to confirm the formation of these nanotubes. Furthermore, was tested and found a high electrochemical stability of the electrode Ti/TiO2-nanotubes/PbO2 for applications such as long-term indicating a good electrocatalytic material. The electrochemical oxidation of AB 113 using Ti/Pt, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 and Al/Al (electrocoagulation) was also studied. However, the best color removal and COD decay were obtained when Ti/TiO2-nanotubes/PbO2 was used as the anode, removing up to 98% of color and 92,5% of COD decay. Analysis of GC/MS were performed in order to identify possible intermediates formed in the degradation of AB 113.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The industrial effluents are one of the main sources of water pollution. For an appropriate characterization and control of their discharges, the most efficient strategy is the integrated use of chemical, physical and ecotoxicological analyses. The aims of this study were to asses the efficiency of the treatment plant of a textile industry performing acute toxicity tests and physical-chemical analyses of the effluents before and after the treatment, besides evaluate the toxicity of the effluents of the Treatment System of Liquids Effluents (Sistema de Tratamento de Efluentes Líquidos - SITEL) of Distrito Industrial de Natal (DIN) and some of their physical-chemical variables. The species used in the ecotoxicological tests was the fish Danio rerio. The results showed that the treatment plant reduced significantly (around 50%) the toxicity of the raw textile effluent in only three of the seven tests but, in general, it promoted the reduction of the physical-chemical parameters analyzed. The toxicity and the physical-chemical factors of the effluents of SITEL of DIN varied among the tests and show the importance of monitoring their discharges in the Potengi river, one of the most important rivers of the Rio Grande do Norte state

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the urban areas of the cities a larger problem of destiny of effluents of the treatment stations is verified due to the junction of the sewages in great volumes. This way the hidroponic cultive becomes important, for your intensive characteristic, as alternative of reuse. This work presents as objective the improvement of the relation hidric-nutritious of the hidroponic cultive of green forage (FVH) using treaty sewage. The production of forage was with corn (Zea mays L.), using double hybrid AG1051, in the experimental field of the Federal University of Rio Grande do Norte (UFRN), in the city of Natal-RN-Brazil. The treated effluent essentially domestic had origin of anaerobic reactor, type decant-digester of two cameras in series followed by anaerobic filters drowned. The hidroponic experimental system was composed of 08 stonemasons, with limited contours for masonry of drained ceramic brick, measuring each one 2,5 meters in length for 1,0 meter of width, with inclination of 4% (m/m) in the longitudinal sense, leveled carefully, in way to not to allow preferential roads in the flow. These dimensions, the useful area of Isow was of 2 square meters. The stonemasons of cultive were waterproof (found and lateral) with plastic canvas of 200 micres of thickness, in the white color. Controlled the entrance and exit of the effluente in the stonemasons, with cycles of 12,68 minutes, it being water of 1,18 minutes. The treatments were constituted of: T1 - 24 hours/day under it waters with flow of 2 L/min; T2 - 12 hours/day under waters with flow of 4 L/min; T3 - 12 hours/day under waters with flow of 2 L/min; and T4 - 16 hours/day under waters with flow of 3 L/min. There were evaluations of the evapotranspirometric demand, of hidroponic system affluent and effluent seeking to characterize and to monitor physical-chemical parameters as: pH, temperature, Electric Conductivity and Fecal Coliforms. This last one was analyzed to the 11 days after isow (DAS) and to the 14 DAS. The others were analyzed daily. I sow it was accomplished in the dates of February 21, 2007, first experiment, and April 10, 2007, second experiment. The density of Isow was of 2 kg of seeds, germinated before 48 hours, for square meter of stonemason. The statistic delineament was it casual entirely with two repetitions, in two experiments. It was applied Tukey test of average to five percent of probability. The cultivation cycle was of 14 DAS with evapotranspirometric demand maximum, reached by T1, of 67,44 mm/day. The analyzed parameters, as mass of green matter - Kg, productivity-Kg/m2 and reason of production of seed FVH/Kg used in Isow, the best result was presented by T1, obtaining value of up to 19,01 Kg/m2 of cultive. Without significant difference, the T4 presented greats values with 16 hours under cycle of water. The Treatments 2 and 3 with 12 hours under cycle of water, they obtained inferior results to the other Treatments. As treatment system, came efficient in the reduction of the salinity. T1 obtained reduction medium maxim of 62,5%, to the 7 DAS, in the amount of salts that enter in the system in they are absorbed in the cultivation. The cultivation FVH acted reducing the microbiologic load. Significant percentile of reduction they were reached, with up to 90,23% of reduction of Units of Colonies (UFC), constituting, like this, the Hidroponic System as good alternative of treatment of effluents of Reactors of high Efficiency

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The water supply and treatment is considered as a great benefit considering that, if done efficiently, provides public health. However, considering the WTP (Water Treatment Plant) is an industry, with its inputs and waste generation, they must be constantly evaluated and monitored to verify the best and most appropriate way to process and dispose their waste, minimizing therefore the potential impacts to the environment. By volume, the most significant waste is the rapid filter backwash water. It is very common the disposal of this waste without treatment in water sources, which are used, for the most part, as a water supply source of a downstream population. This study evaluated quantitative and qualitative parameters in filter backwash water in three WTP - Itaitinga, Maranguape and Pacatuba, located in Ceará State, northeast of Brazil. It was found that the Maranguape WTP, in terms of treatment capacity, is the larger. The Itaitinga WTP is the one that consumes more water during filters washing. The Pacatuba WTP exhibited higher concentration of total suspended and settleable solids, COD and aluminum in the filters backwash water. It is noteworthy that the settleable solids and total suspended solids in all three WTP are above the effluent discharge standard recommended by Resolution 154/2002 of SEMACE (State Superintendent of Environment of Ceará). It was concluded that the filter backwash water from the study WTP exceeded the allowed values for legislation to be disposed directly into surface water bodies. It is suggested as an alternative to treat and recycle the filter backwashing water the construction of sludge settling ponds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the numerous advantages resulting from the use of membrane filters technology, intrinsic limitations fouling process become relevant to its applicability. The control of operating conditions is an important tool to mitigate fouling and achieve good levels of efficiency. In this sense, the objective of this study was to investigate the effect of transmembrane pressure and concentrate flow in the performance of ultrafiltration, applied to the post-treatment of domestic sewage. The process was evaluated and optimized by varying the pressure (0.5 and 1.5 bar) and the concentrate flow (300 and 600 L/h), using a 22 factorial design, in order to investigate the effects on the permeate flow and quality of effluents generated at each operating condition. We evaluated the following quality indicators for permeate: pH, electrical conductivity, total suspended solids, turbidity, calcium and Chemical Oxygen Demand (COD). In all tests, we observed marked reduction in the permeate flux at the early stages, followed by a slow decline that lasted until it reaches a relatively constant level, around 120 minutes of filtration. The increased pressure resulted in a higher initial permeate flux, but the decrease of the flow with time is greater for tests at higher pressure, indicating a more pronounced fouling process. On the other hand, increasing the concentrate flow resulted in a slower decline in permeate flux with the filtration time. Regarding the quality of permeate, the transmembrane pressure of 0,5 bar was the one that allowed better results, and was statistically confirmed through the two-way ANOVA test with repeated measures, significant effect of pressure on the turbidity of the permeate. The concentrate flow, in turn, showed no significant influence on any of the quality parameters. Thus, we conclude that, from an economic and environmental point of view, it is more interesting to operate ultrafiltration membrane system with a lower concentrate flow associated with a low transmembrane pressure, since under these conditions will produce less waste, and the permeate will present lower concentrations of the analyzed constituent, especially lower turbidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The industrial effluents are one of the main sources of water pollution. For an appropriate characterization and control of their discharges, the most efficient strategy is the integrated use of chemical, physical and ecotoxicological analyses. The aims of this study were to asses the efficiency of the treatment plant of a textile industry performing acute toxicity tests and physical-chemical analyses of the effluents before and after the treatment, besides evaluate the toxicity of the effluents of the Treatment System of Liquids Effluents (Sistema de Tratamento de Efluentes Líquidos - SITEL) of Distrito Industrial de Natal (DIN) and some of their physical-chemical variables. The species used in the ecotoxicological tests was the fish Danio rerio. The results showed that the treatment plant reduced significantly (around 50%) the toxicity of the raw textile effluent in only three of the seven tests but, in general, it promoted the reduction of the physical-chemical parameters analyzed. The toxicity and the physical-chemical factors of the effluents of SITEL of DIN varied among the tests and show the importance of monitoring their discharges in the Potengi river, one of the most important rivers of the Rio Grande do Norte state