12 resultados para ECCENTRIC CONTRACTIONS
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.
Resumo:
Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.
Resumo:
Sulfated polysaccharides comprise a complex group of macromolecules with a range of several biological activities, including antiviral activity, anticoagulant, antiproliferative, antiherpética, antitumor, anti-inflammatory and antioxidant. These anionic polymers are widely distributed in tissues of vertebrates, invertebrates and algae. Seaweeds are the most abundant sources of sulfated polysaccharides in nature. The green algal sulfated polysaccharides are homo or heteropolysaccharides comprised of galactose, glucose, arabinose and/or glucuronic acid. They are described as anticoagulant, anti-inflammatory, antiviral, anti-angiogenic, antitumor compounds. However, there are few studies about elucidation and evaluation of biological/pharmacological effects of sulfated polysaccharides obtained from green algae, for example, there is only one paper reporting the antinociceptive activity of sulfated polysaccharides of these algae. Therefore this study aimed to obtain sulfated polysaccharides of green seaweed Codium isthmocladum and evaluates them as potential antinociceptive agents. Thus, in this study, the total extract of polysaccharides of green alga C. isthmocladum was obtained by proteolytic digestion, followed by fractionation resulting in five fractions (F0.3, F0.5, F0.7, F0.9 and F1.2) by sequential precipitation with acetone. Using the test of abdominal contractions we observed that the fraction F0.9 was the most potent antinociceptive aompound. F0.9 consists mainly of a sulfated heterogalactana. More specific tests showed that Fo.9 effect is dose and time dependent, reaching a maximum at 90 after administration (10 mg / kg of animal). F0.9 is associated with TRPV1 and TRPA1 receptors and inhibits painful sensation in animals. Furthermore, F0.9 inhibits the migration of lymphocytes induced peritonitis test. On the other hand, stimulates the release of NO and TNF-α. These results suggest that F0.9 has the potential to be used as a source of sulfated galactan antinociceptive and anti-inflammatory
Resumo:
The objective of this study was to evaluate the effect of low laser power on the performance of anaerobic endurance of the quadriceps muscle in young subjects. Low-level laser therapy (LLLT) appears to decrease some indices of muscle fatigue. Most of these effects may be due to the influence of the laser on the muscles predominantly aerobic. Animal studies and clinical trials have already shown that the laser can improve the efficiency of mitochondrial metabolism for the resynthesis of adenosine triphosphate and thus slow down - or minimize, the deleterious effects of muscle fatigue. This research was characterized as an experimental study of the controlled clinical trial, randomized, blinded, attended by 93 volunteers, military, with ages between 18 and 19 years. The subjects were randomly allocated into three groups: Control (G1), Placebo (G2) and Laser (G3). All volunteers underwent an anthropometric assessment and a protocol Fatigue. This protocol was applied to an initial assessment (AV-1) for the collection of baseline data, and a final evaluation (AV-2). As the study variables, we used the blood lactate concentrations and indices of muscle power, as average power and peak velocity. The fatigue protocol consisted of a test of speed with twenty repetitions, performed on an exercise machine leg press 45º . In conclusion, it was found that, in this study, LLLT caused a significant increase in the Average of the Averages Powers, phase eccentric exercise in leg press 45º performed by young individuals
Resumo:
Introduction: The sport practiced by people with disabilities has been growing in recent years. Consequently, advances in assessment and training methods have emerged. However, the paralympic sport keeps in tow these advances, with few specific studies that consider disability as intervening factor. The transcranial direct current stimulation (tDCS) is a technique that has proven to be capable of modulating brain function. Studies show beneficial effects of tDCS on muscle strength, power and fatigue during exercise. Objective: Investigate de the effect of tDCS on movement control in para-powerlifters. Methods: Eight subjects underwent two sessions of motion capture, which previously applied the anodic tDCS or sham sessions in the cerebellum. Three movements were performed with increasing load between 90-95% of 1MR. The movements were recorded by an 10 infrared cameras system which reconstructed the 3D trajectory of markers placed on the bar. Results: There have been changes between the anodic and sham conditions over bar level (initial, final, maximum during the eccentric and concentric phase) and in the difference between the final and initial bar level. Moreover, there was difference in bar level (final and during the eccentric phase) comparing athletes amputees and les autres. Conclusion: The findings of this study suggest that tDCS applied prior to the exercise over the cerebellum in para-powerlifters acts differently according to disability
Resumo:
The pumping through progressing cavities system has been more and more employed in the petroleum industry. This occurs because of its capacity of elevation of highly viscous oils or fluids with great concentration of sand or other solid particles. A Progressing Cavity Pump (PCP) consists, basically, of a rotor - a metallic device similar to an eccentric screw, and a stator - a steel tube internally covered by a double helix, which may be rigid or deformable/elastomeric. In general, it is submitted to a combination of well pressure with the pressure generated by the pumping process itself. In elastomeric PCPs, this combined effort compresses the stator and generates, or enlarges, the clearance existing between the rotor and the stator, thus reducing the closing effect between their cavities. Such opening of the sealing region produces what is known as fluid slip or slippage, reducing the efficiency of the PCP pumping system. Therefore, this research aims to develop a transient three-dimensional computational model that, based on single-lobe PCP kinematics, is able to simulate the fluid-structure interaction that occurs in the interior of metallic and elastomeric PCPs. The main goal is to evaluate the dynamic characteristics of PCP s efficiency based on detailed and instantaneous information of velocity, pressure and deformation fields in their interior. To reach these goals (development and use of the model), it was also necessary the development of a methodology for generation of dynamic, mobile and deformable, computational meshes representing fluid and structural regions of a PCP. This additional intermediary step has been characterized as the biggest challenge for the elaboration and running of the computational model due to the complex kinematic and critical geometry of this type of pump (different helix angles between rotor and stator as well as large length scale aspect ratios). The processes of dynamic generation of meshes and of simultaneous evaluation of the deformations suffered by the elastomer are fulfilled through subroutines written in Fortan 90 language that dynamically interact with the CFX/ANSYS fluid dynamic software. Since a structural elastic linear model is employed to evaluate elastomer deformations, it is not necessary to use any CAE package for structural analysis. However, an initial proposal for dynamic simulation using hyperelastic models through ANSYS software is also presented in this research. Validation of the results produced with the present methodology (mesh generation, flow simulation in metallic PCPs and simulation of fluid-structure interaction in elastomeric PCPs) is obtained through comparison with experimental results reported by the literature. It is expected that the development and application of such a computational model may provide better details of the dynamics of the flow within metallic and elastomeric PCPs, so that better control systems may be implemented in the artificial elevation area by PCP
Resumo:
Patellofemoral pain syndrome (PFPS) is described as anterior or retropatellar pain knee in the absence of other pathologies and is frequently associated with dysfunction of the vastus medialis oblique (VMO). However, several studies have demonstrated the inability to selectively activate this muscle through exercise. To evaluate the effect of Neuromuscular Electrical Stimulation (NMES) selective VMO in women with syndrome. We evaluated thirty-eight women: twenty in the control group (24.15 ± 2.60 years) and eighteen diagnosed with PFPS (25.56 ± 3.55 years). Both groups were evaluated before and after a protocol of electro stimulation. To measure for comparing groups before and after treatment, we assessed the extensor torque concentric and eccentric knee through an isokinetic dynamometer, the intensity (Root Mean Square - RMS) and the onset of activation (onset) of VMO compared to the vastus lateralis (VL) in two types of exercise: open and closed kinetic chain. . Statistical analysis was performed using SPSS 15.0, with a significance level of 5%. Results: Our data showed an increase in the intensity of activation (RMS) of the VMO muscle after NMES in both study groups. During concentric contraction the RMS of the VMO before the NMES was 105.69 ± 32.26 μV and after a single intervention was 122.10 ± 39.62 μV (p = 0.048) for the control group. In the group with PPS, we found a similar behavior, with RMS of the VMO before NMES of 96.25 ± 18.83 μV and 139.80 ± 65.88 μV after the intervention (p = 0.0001). However, there was no evidence in the RMS value of VL muscle. The onset was calculated by subtracting the onset of VL by the onset of VMO. For the group with PFPS, the onset before the intervention was -0.007 ± 0.14 ms, indicating a delay of the VMO relative to VL, and after NMES was 0.074 ± 0.09 ms (p = 0.016), showing an activation previous VMO to VL. The same occurred for the control group. We also observed that NMES increased knee extensor power during the concentric contraction in both groups. Before the intervention the mean power was 28.97 ± 9.01 W for the PPS group and after NMES was 34.38 ± 7.61 W (p = 0.0001). Conclusion: We observed an increase in electromyographic activity of the VMO and also an anticipatory effect of this muscle
Resumo:
To evaluate the effects of warm-up and stretching, singly or combined, on isokinetic performance and electromyographic activity of the biceps femoris. Materials and methods: Sixty-four volunteers of both sexes, with mean age of 23,1 ± 3,5 years and mean body mass index of 23,5 ± 2,5 Kg/m2 were randomly assigned into 4 groups: control, warm-up (stationary bicycle for 10 minutes), stretching (4 sets of 30 seconds of hamstring muscles static stretching) and warm-up + stretching. All the volunteers were submitted to evaluation pre and post-intervention of the muscle latency time and biceps femoris RMS and the passive torque, peak torque and power of the hamstring muscles. Results: The warm-up + stretching group had reduction of muscle latency time. There was a reduction of RMS during passive torque evaluation in stretching group. The RMS during isometric evaluation was reduced in all experimental groups. The RMS during eccentric evaluation showed reduction in control and warm-up + stretching groups. The passive torque and the eccentric peak torque had no significant differences pre to post-intervention in any group. There was reduction in isometric peak torque in all groups. Conclusion: The warm-up and stretching, when applied in combination can reduce the muscle latency time; stretching protocol promoted neural changes; the protocols used did not alter the muscle viscoelastic properties
Resumo:
Objective: To evaluate the effect of different resting periods, after induced muscle fatigue, in the quadriceps femoris neuromuscular performance, in healthy subjects. Methods: Sixty-four volunteers, of both genders, with an average of 21,8 ± 1,7 years and mean body mass index of 24,2 ± 3,7 Kg/m2 were randomly assigned into 4 groups: control group (was not induced fatigue); Experimental Group 1 (Exp. 1 1 minute of rest after fatigue); Experimental Group 3 (Exp. 3 3 minutes of rest after fatigue) and Experimental Group 5 (Exp. 5 5 minutes of rest after fatigue). The subjects were evaluated to the knee´s joint position sense (JPS), followed by 5 flexion-extension knee concentric isokinetic contractions at 60°/s, with concomitant recording of median frequency (Fmed) of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM). Then they underwent a muscle fatigue protocol (30 flexion-extension knee concentric contractions at 60°/s) and were reevaluated on the isokinetic performance, Fmed and JPS. Blood lactate levels were measured before initial assessment, immediately after the fatigue protocol and 5 minutes after the end of the rest period. Results: The adoption of 3 minutes of rest was sufficient to restore the initial conditions for the peak torque normalized by body weight and the VL and VM Fmed. The joint position sense returned to its initial values with 1 minute rest. The lactate concentration remained high regardless of the adopted rest period. Conclusion: The use of 3-minute rest period is sufficient for the reestablishment of the neuromuscular parameters to the pre fatigue values.
Resumo:
Objective: To evaluate the acute effects of static stretching before and after isokinetic exercise, neuromuscular and biomechanical properties of muscles Biceps Femoris (BF) and semitendinosus (ST). Methods: Eighty-nine volunteers of both genders, healthy and physically active, with a mean age of 22.52 ± 2.6 years and mean BMI 23.86 ± 3.2 kg/m² were randomized into 4 groups: Control Group (CG) made only one Protocol Exercise (PE) without performing the stretching, the Experimental Group 1 (EG1) did stretching before PE; EG2 did the stretching after PE and EG3 did stretching before and after PE. The volunteers were evaluated on the following variables: Range of motion (ROM), soreness, dynamometric variables concentric and eccentric, Neuromuscular Latency Time (NLT) and electromyographic. In the data analysis was assigned a significance level of 5%. Results: ADM and TLNM reported significant reduction in CG, but remained unchanged in GE with p<0,05 and p<0,01, respectively. As for the soreness, no differences between the groups. The electromyographic activity of the BF and ST, in the concentric phase, showed a significant decrease in all groups (p<0,01). However, in the eccentric phase, ST revealed reduction in all groups (p <0.01), except for the CG, while the BF remained unchanged in all groups. The PT showed significant reduction in both conditions (concentric and eccentric) for all groups, with no difference between them (p<0,01). Conclusion: The results of this study do not favor the use of static stretching, even of short duration, before physical activity. However, after exercise or at times unrelated to the sport, he should be given with the aim of avoiding muscle shortening
Resumo:
The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue
Resumo:
Exercise-induced muscle damage mainly affects individuals who returned to physical activity after a time without practicing it or had some kind of exhaustive exercise, particularly eccentric exercise. To evaluate the effect of cryotherapy and laser therapy in response to muscle damage induced by eccentric exercise on the biceps muscle. This was a randomized clinical trial consisting of 60 female subjects. All subjects initially underwent an evaluation consisting of perimetry, measurement of pain sensation (via algometry and visual analogue scale), electromyography and dynamometry. Then the subjects performed an exercise protocol on the isokinetic dynamometer consisting of 2 sets of 10 eccentric elbow flexors contraction at 60 °/s. Completed this protocol, an intervention was held according to a previously random group distribution: control group (no intervention), cryotherapy group and laser therapy group. Finally, subjects were re-evaluated immediately and 48 hours after the intervention protocol, except for Visual Analogue Scale (VAS), which was also evaluated 24 hours after exercise. The circumference of the limb, the pain sensation (VAS and algometry), the muscle activation amplitude (via Root Mean Square - RMS), median frequency, peak torque normalized per body weight, average peak torque, power and work were analyzed. The median frequency immediately after the intervention protocol on the cryotherapy group was the only variable that showed inter and intra-group differences; the remaining variables showed only intragroup differences. The perimetry values did not change immediately after the protocol on the groups which underwent cryotherapy and laser therapy, however, there was an increase after 48 hours; algometry values decreased in all groups for 48 hours and the VAS values increased 24 and 48 hours also for all groups. Regarding RMS no significant change was observed. For dynamometry, peak torque normalized per body weight and average peak torque had a similar behavior, with a reduction in the post protocol that has remained after 48 hours. For the power and work, a decrease was observed immediately after the protocol with a further reduction after 48 hours. Cryotherapy and laser therapy does not alter the muscle damage response, except for the perimetry values immediately after exercise.