17 resultados para Desconforto térmico local

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Goat breeding in the state of Rio Grande do Norte, Brazil has promising economic possibilities, with the proper handling of the natural resources. The introduction of specialized animals has been one of the ways used to improve herd genetics and increase productivity. However, climate has been one of the regional factors that most interferes with the adaptation of the new genetic prevalence resulting from the introduction of exotic breeds, because in their country of origin, the air temperature during most of the year is lower than the animals body temperature. With this in mind, the aim of this study was to characterize behavioral, physiological and morphological profiles and milk production of female Saanen goats belonging to different genetic groups raised in the semi-arid region of Rio Grande do Norte in Northeast Brazil. The study was conducted in the city of Lages (5° 42 00 S and 36° 14 41 W). We used 25 lactating female Saanen goats, distributed into 3 genetic groups: 5 purebred animals, 11 three-quarter bred and 9 half-bred. Behavioral observations were made over three consecutive days in the months of August and September, between 09:00 and 11:30h, when the animals were grazing. Physiological and meteorological data were recorded in the last three days of June, July, August and September at 05:00h and at 16:00h. In the semi-intensive breeding system, the animals from different genetic groups were similar in both field behavior and physiological response patterns. Although the purebred goats had longer hair, they did not show symptoms of thermal discomfort. Their white hair helped to reflect the short wavelength rays and thus eliminate those at the longer wave lengths. We concluded that the animals raised in the semi-intensive milk production system in this study seem to have adapted to the climatic conditions of the semi-arid region of Rio Grande do Norte, Brazil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Owing to na intense process of urban development, urban uneasiness and discomfort in the daily life of populations have nowadays, especially in the big cities, become increasingly ordinary issues. Population density, degeneration of central areas and pollution are some of the environmental stressors the urban man is subjected to. The existence of open areas in the urban network contributes to a better movement of the air and transforms salubrity conditions. Yet, it has been noticed that parks and squares are disappearing from the heart of the city districts. In their place there are either unused plots of land where garbage has been dumped or nearly all-paved squares with meager or no vegetation at all. Such areas, when handled properly, play an important role in the city because in addition to being zones for rendering a mild climate they perform social, cultural and hygienic functions. Aiming at demonstrating that proper handling of green areas can favorably influence the local microclimate, we have attempted to develop analysis from the point of view of bioclimatizing attributes of urban form and their relationship to the local microclimate found in the eight open areas located in the Ponta Negra Housing Complex in the city of Natal/RN

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The employment of flexibility in the design of façades makes them adaptable to adverse weather conditions, resulting in both minimization of environmental discomfort and improvement of energy efficiency. The present study highlights the potential of flexible façades as a resource to reduce rigidity and form repetition, which are usually employed in condominiums of standardized houses; as such, the work presented herein contributes to field of study of architectural projects strategies for adapting and integrating buildings within the local climate context. Two façade options were designed using as reference the bionics and the kinetics, as well as their applications to architectural constructions. This resulted in two lightweight and dynamic structures, which cater to constraints of comfort through combinations of movements, which control the impact of solar radiation and of cooling in the environment. The efficacy and technical functionality of the façades were tested with comfort analysis and graphic computation software, as well as with physical models. Thus, the current research contributes to the improvement of architectural solutions aimed at using passive energy strategies in order to offer both better quality for the users and for the sustainability of the planet

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Owing to na intense process of urban development, urban uneasiness and discomfort in the daily life of populations have nowadays, especially in the big cities, become increasingly ordinary issues. Population density, degeneration of central areas and pollution are some of the environmental stressors the urban man is subjected to. The existence of open areas in the urban network contributes to a better movement of the air and transforms salubrity conditions. Yet, it has been noticed that parks and squares are disappearing from the heart of the city districts. In their place there are either unused plots of land where garbage has been dumped or nearly all-paved squares with meager or no vegetation at all. Such areas, when handled properly, play an important role in the city because in addition to being zones for rendering a mild climate they perform social, cultural and hygienic functions. Aiming at demonstrating that proper handling of green areas can favorably influence the local microclimate, we have attempted to develop analysis from the point of view of bioclimatizing attributes of urban form and their relationship to the local microclimate found in the eight open areas located in the Ponta Negra Housing Complex in the city of Natal/RN

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The employment of flexibility in the design of façades makes them adaptable to adverse weather conditions, resulting in both minimization of environmental discomfort and improvement of energy efficiency. The present study highlights the potential of flexible façades as a resource to reduce rigidity and form repetition, which are usually employed in condominiums of standardized houses; as such, the work presented herein contributes to field of study of architectural projects strategies for adapting and integrating buildings within the local climate context. Two façade options were designed using as reference the bionics and the kinetics, as well as their applications to architectural constructions. This resulted in two lightweight and dynamic structures, which cater to constraints of comfort through combinations of movements, which control the impact of solar radiation and of cooling in the environment. The efficacy and technical functionality of the façades were tested with comfort analysis and graphic computation software, as well as with physical models. Thus, the current research contributes to the improvement of architectural solutions aimed at using passive energy strategies in order to offer both better quality for the users and for the sustainability of the planet