14 resultados para Dental prostheses and dental implants
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.
Resumo:
Recent years have seen a significant growth in surface modifications in titanium implants, resulting in shorter healing times in regions with low bone density. Among the different techniques, subtraction by chemical agents to increase oxidation has been applied for surface treatment of dental implants. However, this technique is generally unable to remove undesirable oxides, formed spontaneously during machining of titanium parts, raising costs due to additional decontamination stages. In order to solve this problem, the present study used plasma as an energy source to both remove these oxides and oxidize the titanium surface. In this respect, Ti disks were treated by hollow cathode discharge, using a variable DC power supply and vacuum system. Samples were previously submitted to a cleaning process using an atmosphere of Ar, H2 and a mixture of both, for 20 and 60 min. The most efficient cleaning condition was used for oxidation in a mixture of argon (60%) and oxygen (40%) until reaching a pressure of 2.2 mbar for 60 min at 500°C. Surfaces were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), adhesion and cell proliferation. SEM showed less cell spreading and a larger number of projections orfilopodia in the treated samples compared to the control sample. AFM revealed surface defects in the treated samples, with varied geometry between peaks and valleys. Biological assays showed no significant difference in cell adhesion between treated surfaces and the control. With respect to cell proliferation, the treated surface exhibited improved performance when compared to the control sample. We concluded that the process was efficient in removing primary oxides as well as in oxidizing titanium surfaces
Resumo:
In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge
Resumo:
This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study
Resumo:
Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures
Resumo:
It has been shown that the development of peri-implant mucositis is associated with biofilm accumulation. It is believed that the therapeutic approaches used in periodontal disease may have a positive effect in the cases of peri-implant disease. The aim of this study was to evaluate the effectiveness of non-surgical treatment of peri-implant mucositis, with or without the use of chlorhexidine 0,12% in subjects rehabilitated with osseointegrated implants. Thus, patients were randomly divided into test group (chlorhexidine surgical therapy) and control (non-surgical treatment). This therapy consisted of an adaptation of the (Full Mouth scalling and Root Planing) nonoperative protocol FMSRP, but without the use of ultrasound. The visible plaque index (VPI), gingival bleeding index (GBI), probing depth (PD), bleeding on probing (BOP) and keratinized mucosa clinical parameters were evaluated at baseline and at different times after treatment. The data were not normally distributed and the implant was considered the sampling unit. Data were analyzed using Fri edman and Wilcoxon chi-square (=5%), tests using the Statistical Package for Social Sciences 17.0 (SPSS). Thus, 119 implants were evaluated, 61 in the test group and 58 in the control group. The results showed statistically significant differences for the variables: average BTI implants in both groups (p<0,001), mean ISG implants both in the test group (p<0,001), and control (p= 0,006) of implants; PS for the test group (p< 0,001) and control (p = 0,015) and SS (p<0,001) in the two treatment groups. However, there was no statistically significant difference when the groups were compared. The PS and SS variables showed no statistically significant difference in any of independent interest to the study (age, sex, smoking, treatment group, keratinized mucosa at different times, peri-implant biotype, average VPI implants and GBI). Thus, it can be concluded that both the mechanical treatment isolated as its association with chlorhexidine mouthwash 0.12% can be used for the treatment of peri-implant mucositis. Moreover, the condition of oral h ygiene has improved between baseline and six months and the depth and bleeding on probing decreased after three and six months
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques
Resumo:
Introduction: Infiltration of organic fluids and microorganisms at the abutment/implant interface may result in bacterial infection of peri-implant tissues. Internal colonization of periodontal pathogens may be caused by bacteria trapped during installation or penetration of abutment/implant leakage. The aim of this study was to detect periodontal pathogens in the internal area of dental implants before loading. Materials and Methods: Seventy-eight implants in 32 partially edentulous subjects were selected for this evaluation. A bacterial biofilm sample of the internal surface of each implant was taken and analyzed for the presence of 40 microorganisms by checkerboard DNA-DNA hybridization, prior to installation of healing or any other prosthetic abutment. Discussion: Bacteria were detected in 20 patients (62.5%), distributed in 41 implants (52.6%). Forty-seven percent of implants showed no bacterial detection. Spontaneous early implant exposure to oral cavity during the healing period was not significant (P >0.05) to increase bacterial prevalence, but implants placed at mandible had higher bacterial prevalence than maxillary ones. Conclusion: The internal surface of dental implants can serve as a reservoir of periodontal pathogens for future implant/abutment interface.
Resumo:
A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.
Resumo:
A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.
Resumo:
Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.
Resumo:
A introdução dos implantes dentários osseointegrados como uma ferramenta na reabilitação oral de pacientes edêntulos e parcialmente edêntulos é uma realidade no cotidiano do cirurgião-dentista. Estudos reportam uma alta taxa de sucesso da utilização de implantes no tratamento reabilitador. Entretanto, outras investigações têm mostrado a perda desses implantes devido a infecções peri-implantares, como a mucosite e a peri-implantite. O objetivo deste trabalho foi avaliar a frequência das doenças peri-implantares e seus fatores associados em pacientes com implantes dentais em função reabilitados no serviço odontológico da Faculdade de Odontologia da UFRN. Foram examinados 155 indivíduos portadores de 523 implantes e 2718 dentes. Dentes e implantes foram avaliados por meio de sondagem periodontal, observando-se a profundidade de sondagem, retração gengival, bem como foram avaliados índices de placa visível (IPV) e sangramento gengival (ISG) e presença de supuração. Os dados foram armazenados em fichas clínicas e avaliados estatisticamente por meio da estatística descritiva e inferencial. A idade média dos pacientes foi de 54,05 (± 12,61) anos, sendo 79,4% do sexo feminino. As frequências da mucosite, peri-implantite e periodontite em indivíduos foram 54%, 28% e 50%, respectivamente. Dos 523 implantes avaliados, 43% tinham mucosite, 14% peri-implantite e 43% saúde. Os testes Qui-quadrado de Pearson e Exato de Fisher mostraram que as doenças peri-implantares estão associadas as doenças periodontais, uso de medicação, alterações sistêmicas número de implantes, IPV, ISG, ao tempo de função das próteses, região do implante, número de roscas expostas e faixa de mucosa queratinizada (p<0,05). A análise de regressão múltipla, através da regressão binária logística, constatou que indivíduos que faziam uso de medicação (OR = 1,784), com um ISG > 10% (OR = 1,742), com implantes instalados na maxila (OR = 2,654), onde a prótese sobre o implante tinham mais de 2 anos em função (OR = 3,144) e que radiograficamente apresentavam uma perda óssea atingindo a terceira rosca do implante (OR = 4,701) mostram uma associação positiva com as doenças peri-implantares de maneira que esses indivíduos têm mais chances de ter essas doenças. Os resultados sugerem que a frequência das doenças peri-implantares na população em estudo foi de 82% dos pacientes e que estas doenças estão associadas a fatores relacionados aos indivíduos como: a presença da doença periodontal, piores IPV e IS, alterações sistêmicas, uso de medicação e maior número de implantes; e a fatores locais relacionados aos implantes como: ausência ou faixa de mucosa menor que 2mm, implantes na maxila e na região anterior, perda óssea atingindo a terceira rosca do implante e a um tempo de reabilitação prótetica maior que 2 anos
Resumo:
The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above