7 resultados para Densidade de centro

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

VANTI, Nadia; SILVA, Lailde da. Análise webométrica das Universidades Públicas Federais das Regiões Norte e Centro- oeste do Brasil.In: ENCONTRO NACIONAL DE ESTUDANTES DE BIBLIOTECONOMIA, DOCUMENTAÇÃO, GESTÃO, E CIÊNCIA DA INFORMAÇÃO,33 , 2010, Paraíba. Anais... Paraíba: ENEBD, 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Squamous cell carcinoma of the lower lip is among the most common malignant tumors of the oral and maxillofacial region, with good prognosis in more than 90% of patients with 5-year survival. In these carcinomas, the development of lymph node metastasis decreases the prognosis and it has been associated with the formation of new lymphatic vessels. It has been suggested the important role of vascular endothelial growth factor-C (VEGF-C), the receptor type 3 VEGF (VEGFR-3) and hypoxia-induced factor 1 (HIF-1) in this process. The aim of this study was to evaluate the immunoexpression of VEGF-C, VEGFR-3 and HIF-1α and correlate with intra and peritumoral lymphatic density in squamous cell carcinomas of the lower lip metastatic and non-metastatic. The sample consisted of 50 cases of squamous cell carcinoma of lower lip, of which 25 had regional lymph node metastasis and 25, absence of metastasis. The percentages of cells immunostained for VEGF-C, VEGFR-3 and HIF-1α in front of tumor invasion and in the center of tumor were evaluated. Microvessel density lymphatic (MDL) was determined by the counting of lymph microvessels immunostained by the anti-D2-40 in five fields (200×), in an area of evaluation with 0.7386 mm2. The invasion of the lymph vessels by malignant cells was also evaluated. Immunostaining was correlated with the presence and absence of metastasis, TNM clinical stage, local recurrence, disease outcome (remission of injury or patient death) and histological grading. The analysis of intra and peritumoral lymphatic density showed no significant association with clinicopathological parameters and immunoexpressions of VEGF-C, VEGFR-3 and HIF-1α (p > 0,05). There was a weak positive correlation, significant, between intra and peritumoral lymphatic density (r = 0,405; p = 0,004). VEGF-C showed no significant association with clinicopathological and prognosis parameters (p > 0,05). For VEGFR-3, there was scarce membrane staining and intense and homogenous cytoplasmic staining in neoplastic cells. Percentage of positive cytoplasmic VEGFR-3 in center of tumor, exhibited a statistically significant association with metastasis (p = 0,009), patient death (p = 0,008) and histological grades of malignancy proposed by Bryne et al. (1992) (p = 0,002) and World Health Organization (p = 0,003). A low positive correlation was statistically significant between the immunoreactivity of VEGFC and VEGFR-3 cytoplasmic (r = 0,358; p = 0,011) and between the percentage of positive cytoplasmic VEGFR-3 in front of tumor invasion and in the center of the tumor (r = 0,387; p = 0,005) was also demonstrated. There was no association between HIF-1α, clinicopathological and prognosis parameters, and VEGF-C and VEGFR-3. The percentage of nuclear positivity for HIF-1α was significantly higher in cases without invasion of peritumoral lymphatic (p = 0,040). Based on the results we can conclude that most cytoplasmic expression of VEGFR-3 in center of tumor in metastatic cases, high degree of malignancy and poorly differentiated, contributes to poor outcome of squamous cell carcinoma of the lower lip, including patient death. Intra and peritumoral lymphatic density seems to be not associated with lymph node metastasis in these carcinomas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the species of freshwater shrimp being cultivated, Macrobrachium rosenbergii stands out. Knowledge about the behavior of this species and the influence of certain factors on its development can help optimize management practices and minimize the likely impacts shrimp farming has on the environment and the animals themselves. The objective of this study was to characterize the species' behavior during early stages of development under different stocking densities over a 24-hour cycle. Ten day old postlarvae were transferred from the Jundiaí School of Agriculture (EAJ - Escola Agrícola de Jundiaí) in Macaíba (RN), Brazil to the Shrimp Behavior Laboratory (LSPR - Laboratório de Estudos do Comportamento do Camarão) at the Federal University of Rio Grande do Norte (UFRN), where they were weighed and measured. Eight aquaria with constant temperature, aeration and filtration, and subjected to a12 h light/12 h dark cycle were used for each experiment. Each aquarium also contained two shelters made of bricks and the water quality was monitored weekly. Behavioral observations were made at two densities: 25 individuals/m-² and 40 individuals/m-². The methods for recording behaviors were: behavioral sampling – enter and leave the shelter, exploring on the substrate, exploring in the water column, move away, attack, pursuit and cannibalism; scan sampling - inactivity, feeding, exploration, digging, swimming, cleaning and staying in the shelter. Observations were made during a 15 minute period/per aquarium at a frequency of 4 times daily, for 4 days/week, and over 4 weeks. Food was provided 2 times/day for each aquarium population, immediately before the 1st and 3rd observation periods. Our results demonstrate that at high density, there is an increased frequency of agonistic behavior; during the light phase, there is a greater frequency of behaviors that result in less exposure (inactivity, cleaning and staying in the shelter); during the dark phase, there is an increased frequency of behaviors that result in greater exposure (feeding, exploration, swimming and digging); at times of feed offer, there is an increased frequency of leaving the shelter, moving away, pursuit, feeding, exploration and swimming. At low density, the animals showed a lower frequency of agonistic behaviors, greater weight gain and higher growth rates, which indicates that this is a more favorable growing environment for cultivation and when applied, can generate better living conditions, favor survival rates and increase management success

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discovery that a spin-polarized current is capable of exerting a torque in a ferromagnetic material, through spin transfer, might provide the development of new technological devices that store information via the direction of magnetization. The reduction of current density to revert the magnetization is a primary issue to potential applications on non volatile random access memories (MRAM). We report a theorical study of the dipolar and shape effects on the critical current density for reversal of magnetization, via spin transfer torque (STT), on ferromagnetic nanoelements. The nanostructured system consists on a reference layer, in which the current will be spin-polarized, and a free layer of magnetization reversal. We observed considerable changes on the critical current density as a function of the element’s reversion layer thickness (t = 1.0 nm, 1.5 nm, 2.0 nm e 2.5 nm) and geometry (circular and elliptical), the material kind of the system free layer (Iron and Permalloy) and according to the orientation of the magnetization and the spin polarization with the major axis. We show that the critical current density may be reduced about 50% by reducing the Fe free layer thickness and around 75% when we change the saturation magnetization of circular nanoelements with 2.5 nm of thickness. We still observed a reduction as much as 90% on the current density of reversion for thin nanoelements magnetized along the minor axis direction, using in-plane spin polarization parallel to the magnetization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

VANTI, Nadia; SILVA, Lailde da. Análise webométrica das Universidades Públicas Federais das Regiões Norte e Centro- oeste do Brasil.In: ENCONTRO NACIONAL DE ESTUDANTES DE BIBLIOTECONOMIA, DOCUMENTAÇÃO, GESTÃO, E CIÊNCIA DA INFORMAÇÃO,33 , 2010, Paraíba. Anais... Paraíba: ENEBD, 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation