5 resultados para Deformidade de membros
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
This work presents the development of a prototype of an intelligent active orthosis for lower limbs whit an electronic embedded system. The proposed orthosis is an orthopedical device with the main objective of providing walking capacity to people with partial or total loss of lower limbs movements. In order to design the kinematics, dynamics and the mechanical characteristics of the prototype, the biomechanics of the human body was analized. The orthosis was projected to reproduce some of the movements of the human gait as walking in straight forward, sit down, get up, arise and go down steps. The joints of the orthosis are controlled by DC motors equipped with mechanical reductions, whose purpose is to reduce rotational speed and increase the torque, thus generating smooth movements. The electronic embedded system is composed of two motor controller boards with two channels that communicate with a embedded PC, position sensors and limit switches. The gait movements of the orthosis will be controlled by high level commands from a human-machine interface. The embedded electronic system interprets the high level commands, generates the angular references for the joints of the orthosis, controls and drives the actuators in order to execute the desired movements of the user
Resumo:
The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above
Resumo:
Chronic venous disease (CVD) is evident among the chronic diseases and affects the elderly population and primarily is responsible for leg ulcers in this population. The use of dressings in the care of a venous ulcer is a fundamental part of the treatment for healing, however, evidence to assist in choosing the best dressing is scarce. The main objective of this study was to evaluate the effectiveness of treatment with hydrogel in the healing of venous ulcers using search methods, synthesis of information and statistical research through a systematic review and meta-analysis. Randomized controlled trials were selected in the following databases: CENTRAL; DARE; NHS EED; MEDLINE; EMBASE; CINAHL. Beyond these databases three websites were consulted to identify ongoing studies: ClinicalTrials.gov, OMS ICTRP e ISRCTN. The primary outcomes were analyzed: complete wound healing, incidence of wound infection and the secondary were: changes in ulcer size, time to ulcer healing, recurrence of ulcer, quality of life of participants, pain and costs of treatment. Four studies are currently included in the review with a total of 250 participants. The use of hydrogel appears to be superior to conventional dressing, gauze soaked in saline, for the healing of venous leg ulcers; 16/30 patients showed complete healing of ulcers (RR 5,33, 95%CI [1,73,16,42]). The alginate gel was shown to be more effective when compared to the hydrogel dressing in reduction of the wound area; 61,2% (± 26,2%) with alginate e 19,4% (± 24,3%) with hydrogel at the end of four weeks of treatment. Manuka honey has shown to be similar to the hydrogel dressings in percentage of area reduction. This review demonstrated that there is no evidence available about the effectiveness of the hydrogel compared to other types of dressings on the healing of venous leg ulcers of the lower limbs, thus demonstrating the need of future studies to assist health professionals in choosing the correct dressing.
Resumo:
In the last decade, an increasing number of studies focusing on the impact of oral deformities on quality of life have been published. However, the evaluation of patients at different phases of the treatment has not been performed. Therefore, the purpose of this study was to determine the impact that dentofacial deformities have on patients` quality of life, as well as the influence exerted by social, economic, demographic and orthodontic factors, type and severity of malocclusion. A bicentric study - of the cross-sectional type of repeated panels - involving two cities - Natal and Rio de Janeiro - was carried out. A total of 227 patients participated in the study: 71 patients in the initial phase of the treatment (before any orthosurgical procedure), 115 patients in the pre-surgical (with braces) phase and 41 patients in the postoperative phase. The quality of life was measured using the Orthognatic Quality of Life Questionnnaire - OQLQ, translated and validated into Portuguese. The normative and aesthetic need for treatment was assessed with the Index of Orthodontic Treatment Need (IOTN) and the Dental Aesthetic Index (DAI); the social, economic and demographic factors, the type of service and malocclusion were also assessed. The data were analyzed through χ2/ Fisher`s exact test to seek the association between the nominal categorical variables in the three phases of treatment, Mann Whitney and Kruskal-Wallis test for gauging the existence of significant differences between two and three groups regarding each domain of OQLQ, respectively. For all tests, it was adopted a significance level of 5%. There was a statistically significant difference (p <0.001) in the general scores of OQLQ and in the domains of social aspects, facial aesthetics and oral function, when the "postoperative group" was compared to the "initial" and "orthodontic preparation" groups. Women, single, aged between 31 and 59 and living in Natal had the greatest impact on quality of life among patients in the "orthodontic preparation" group. Only the variable "income" (2 to 3 minimum wages), for the "initial" group, and gender (female) for the "postoperative" group, showed significant association with quality of life. The normative variable IOTN (DHC and AC) showed significant association with the OQLQ for the "initial" group, and the IOTN-AC-auto in the group of orthodontic preparation, being less important to women. We conclude that the ortho-surgical therapy has positive effects on quality of life after orthognathic surgery
Resumo:
Atualmente com o crescente aumento de dispositivos robóticos destinados para aplicação na área de mobilidade de pessoas que sofreram algum tipo de lesão medular, se faz necessário desenvolver novas ferramentas para tornar tais equipamentos mais adaptáveis, seguros e autônomos. Para que as órteses robóticas que auxiliam na locomoção de pessoas paraplégicas possam desempenhar sua função, estas devem ser capazes de reproduzir os movimentos perdidos com o máximo de fidelidade e segurança em ambientes que eventualmente possam conter obstáculos de diferentes tipos como buracos, escadas e calçadas. As órteses robóticas para membros inferiores têm a capacidade de caminhar, subir e descer degraus, todavia, esses movimentos, na maioria das vezes, não se adaptam ao ambiente, sendo assim, para uma órtese robótica que foi projetada para subir um degrau com uma determinada altura ao se deparar com um degrau maior provavelmente não conseguirá realizar essa tarefa com a mesma segurança. Para solucionar esse e outros problemas, esse trabalho apresenta um Sistema de Auxílio à Locomoção (SAL) dotado de um planejador de passos e um gerador de referências angulares com características antropomórficas para a órtese robótica Ortholeg. O SAL utiliza dados antropométricos do usuário para gerar um padrão de marcha personalizado, dessa forma, a órtese em questão é capaz de adaptar o tamanho do passo para não colidir com obstáculos presentes no ambiente e transpor buracos com diversos tamanhos, subir e descer escadas e calçadas com diferentes valores de altura e comprimento. Para desenvolver o sistema de auxílio à locomoção foram adaptadas técnicas de planejamento de caminho, usadas a princípio em robôs bípedes. São apresentados vários experimentos que mostram a órtese Ortholeg realizando alguns movimentos com características antropomórficas para diferentes distâncias de caminhada e três tipos de obstáculos: degrau, buraco e calçada. A autonomia adquirida com a utilização do sistema de planejamento apresentado facilita a utilização de órteses robóticas como também garante uma maior segurança ao usuário.