Resumo:
This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential
Resumo:
The purpose of this research is to analyze different daylighting systems in schools in the city of Natal/RN. Although with the abundantly daylight available locally, there are a scarce and diffuse architectural recommendations relating sky conditions, dimensions of daylight systems, shading, fraction of sky visibility, required illuminance, glare, period of occupation and depth of the lit area. This research explores different selected apertures systems to explore the potential of natural light for each system. The method has divided into three phases: The first phase is the modeling which involves the construction of three-dimensional model of a classroom in Sketchup software 2014, which is featured in follow recommendations presented in the literature to obtain a good quality of environmental comfort in school settings. The second phase is the dynamic performance computer simulation of the light through the Daysim software. The input data are the climate file of 2009 the city of Natal / RN, the classroom volumetry in 3ds format with the assignment of optical properties of each surface, the sensor mapping file and the user load file . The results produced in the simulation are organized in a spreadsheet prepared by Carvalho (2014) to determine the occurrence of useful daylight illuminance (UDI) in the range of 300 to 3000lux and build graphics illuminance curves and contours of UDI to identify the uniformity of distribution light, the need of the minimum level of illuminance and the occurrence of glare.
Resumo:
This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential